]> git.ipfire.org Git - thirdparty/systemd.git/blobdiff - man/sd_bus_default.xml
man: drop unused <authorgroup> tags from man sources
[thirdparty/systemd.git] / man / sd_bus_default.xml
index c5a1b530f96b30dbd431935b97b018e62d8c2e86..22bcfd64193034f8028c2aeb72a69c7788cf4185 100644 (file)
@@ -3,38 +3,16 @@
 "http://www.oasis-open.org/docbook/xml/4.2/docbookx.dtd">
 
 <!--
-  This file is part of systemd.
+  SPDX-License-Identifier: LGPL-2.1+
 
-  Copyright 2014 Zbigniew Jędrzejewski-Szmek
-
-  systemd is free software; you can redistribute it and/or modify it
-  under the terms of the GNU Lesser General Public License as published by
-  the Free Software Foundation; either version 2.1 of the License, or
-  (at your option) any later version.
-
-  systemd is distributed in the hope that it will be useful, but
-  WITHOUT ANY WARRANTY; without even the implied warranty of
-  MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU
-  Lesser General Public License for more details.
-
-  You should have received a copy of the GNU Lesser General Public License
-  along with systemd; If not, see <http://www.gnu.org/licenses/>.
+  Copyright © 2014 Zbigniew Jędrzejewski-Szmek
 -->
 
-<refentry id="sd_bus_default">
+<refentry id="sd_bus_default" xmlns:xi="http://www.w3.org/2001/XInclude">
 
   <refentryinfo>
     <title>sd_bus_default</title>
     <productname>systemd</productname>
-
-    <authorgroup>
-      <author>
-        <contrib>A monkey with a typewriter</contrib>
-        <firstname>Zbigniew</firstname>
-        <surname>Jędrzejewski-Szmek</surname>
-        <email>zbyszek@in.waw.pl</email>
-      </author>
-    </authorgroup>
   </refentryinfo>
 
   <refmeta>
     <para><function>sd_bus_default()</function> acquires a bus
     connection object to the user bus when invoked in user context, or
     to the system bus otherwise. The connection object is associated
-    to the calling thread. Each time the function is invoked from the
-    same thread the same object is returned, but its reference count
-    is increased by one, as long as at least one reference is
+    with the calling thread. Each time the function is invoked from
+    the same thread, the same object is returned, but its reference
+    count is increased by one, as long as at least one reference is
     kept. When the last reference to the connection is dropped (using
     the
     <citerefentry><refentrytitle>sd_bus_unref</refentrytitle><manvolnum>3</manvolnum></citerefentry>
     call), the connection is terminated. Note that the connection is
     not automatically terminated when the associated thread ends. It
     is important to drop the last reference to the bus connection
-    explicitly before the thread ends or otherwise the connection will
-    be leaked.</para>
+    explicitly before the thread ends, as otherwise, the connection will
+    leak. Also, queued but unread or unwritten messages keep the
+    bus referenced, see below.</para>
 
     <para><function>sd_bus_default_user()</function> returns a user
-    bus connection object associated to the calling thread.
+    bus connection object associated with the calling thread.
     <function>sd_bus_default_system()</function> is similar, but
     connects to the system bus. Note that
     <function>sd_bus_default()</function> is identical to these two
     <function>sd_bus_open_system()</function> does the same, but
     connects to the system bus. In contrast to
     <function>sd_bus_default()</function>,
-    <function>sd_bus_default_user()</function>,
-    <function>sd_bus_default_system()</function> these calls return
+    <function>sd_bus_default_user()</function>, and
+    <function>sd_bus_default_system()</function>, these calls return
     new, independent connection objects that are not associated with
     the invoking thread and are not shared between multiple
     invocations. It is recommended to share connections per thread to
     efficiently make use the available resources. Thus, it is
     recommended to use <function>sd_bus_default()</function>,
-    <function>sd_bus_default_user()</function>,
+    <function>sd_bus_default_user()</function> and
     <function>sd_bus_default_system()</function> to connect to the
     user or system buses.</para>
 
     not set, a suitable default for the default system D-Bus instance
     will be used.</para>
 
-    <para><function>sd_bus_open_system_remote()</function> connects to
-    the system bus on the specified <parameter>host</parameter> using
-    <citerefentry
-    project='die-net'><refentrytitle>ssh</refentrytitle><manvolnum>1</manvolnum></citerefentry>. <parameter>host</parameter>
-    consists of an optional user name followed by the
-    <literal>@</literal> symbol, and the hostname.
-    </para>
+    <para><function>sd_bus_open_system_remote()</function> connects to the system bus on
+    the specified host using
+    <citerefentry project='die-net'><refentrytitle>ssh</refentrytitle><manvolnum>1</manvolnum></citerefentry>.
+    <parameter>host</parameter> consists of an optional user name followed by the
+    <literal>@</literal> symbol, and the hostname, optionally followed by a
+    <literal>:</literal> and a machine name. If the machine name is given, a connection
+    is created to the system bus in the specified container on the remote machine, and
+    otherwise a connection to the system bus on the specified host is created.</para>
+
+    <para>Note that entering a container is a privileged operation, and will likely only
+    work for the root user on the remote machine.</para>
 
     <para><function>sd_bus_open_system_machine()</function> connects
     to the system bus in the specified <parameter>machine</parameter>,
     processes at this time.</para>
 
     <para>These calls allocate a bus connection object and initiate
-    the connection ot a well-known bus of some form. An alternative to
+    the connection to a well-known bus of some form. An alternative to
     using these high-level calls is to create an unconnected bus
     object with
     <citerefentry><refentrytitle>sd_bus_new</refentrytitle><manvolnum>3</manvolnum></citerefentry>
 
   </refsect1>
 
-  <refsect1>
-    <title>Return Value</title>
-
-    <para>On success, these calls return 0 or a positive
-    integer. On failure, these calls return a negative
-    errno-style error code.</para>
-  </refsect1>
-
   <refsect1>
     <title>Reference ownership</title>
     <para>The functions <function>sd_bus_open()</function>,
     <function>sd_bus_open_system()</function>,
     <function>sd_bus_open_system_remote()</function>, and
     <function>sd_bus_open_system_machine()</function> return a new
-    object and the caller owns the sole reference. When not needed
-    anymore, this reference should be destroyed with
+    connection object and the caller owns the sole reference. When not
+    needed anymore, this reference should be destroyed with
     <citerefentry><refentrytitle>sd_bus_unref</refentrytitle><manvolnum>3</manvolnum></citerefentry>.
     </para>
 
     <para>The functions <function>sd_bus_default()</function>,
     <function>sd_bus_default_user()</function> and
     <function>sd_bus_default_system()</function> do not necessarily
-    create a new object, but increase the connection reference by
-    one. Use
+    create a new object, but increase the connection reference of an
+    existing connection object by one. Use
     <citerefentry><refentrytitle>sd_bus_unref</refentrytitle><manvolnum>3</manvolnum></citerefentry>
     to drop the reference.</para>
+
+    <para>Queued but unwritten/unread messages keep a reference to their bus connection object. For this reason, even
+    if an application dropped all references to a bus connection, it might not get destroyed right away. Until all
+    incoming queued messages are read, and until all outgoing unwritten messages are written, the bus object will stay
+    alive. <function>sd_bus_flush()</function> may be used to write all outgoing queued messages so they drop their
+    references. To flush the unread incoming messages, use <function>sd_bus_close()</function>, which will also close
+    the bus connection. When using the default bus logic, it is a good idea to first invoke
+    <function>sd_bus_flush()</function> followed by <function>sd_bus_close()</function> when a thread or process
+    terminates, and thus its bus connection object should be freed.</para>
+
+    <para>Normally, slot objects (as created by
+    <citerefentry><refentrytitle>sd_bus_add_match</refentrytitle><manvolnum>3</manvolnum></citerefentry> and similar
+    calls) keep a reference to their bus connection object, too. Thus, as long as a bus slot object remains referenced
+    its bus object will remain allocated too. Optionally, bus slot objects may be placed in "floating" mode. When in
+    floating mode the life cycle of the bus slot object is bound to the bus object, i.e. when the bus object is freed
+    the bus slot object is automatically unreferenced too. The floating state of a slot object may be controlled
+    explicitly with
+    <citerefentry><refentrytitle>sd_bus_slot_set_floating</refentrytitle><manvolnum>3</manvolnum></citerefentry>,
+    though usually floating bus slot objects are created by passing <constant>NULL</constant> as the
+    <parameter>slot</parameter> parameter of <function>sd_bus_add_match()</function> and related calls, thus indicating
+    that the caller is not directly interested in referencing and managing the bus slot object.</para>
+
+    <para>The life cycle of the default bus connection should be the
+    responsibility of the code that creates/owns the thread the
+    default bus connection object is associated with. Library code
+    should neither call <function>sd_bus_flush()</function> nor
+    <function>sd_bus_close()</function> on default bus objects unless
+    it does so in its own private, self-allocated thread. Library code
+    should not use the default bus object in other threads unless it
+    is clear that the program using it will life cycle the bus
+    connection object and flush and close it before exiting from the
+    thread. In libraries where it is not clear that the calling
+    program will life cycle the bus connection object, it is hence
+    recommended to use <function>sd_bus_open_system()</function>
+    instead of <function>sd_bus_default_system()</function> and
+    related calls.</para>
+  </refsect1>
+
+  <refsect1>
+    <title>Return Value</title>
+
+    <para>On success, these calls return 0 or a positive
+    integer. On failure, these calls return a negative
+    errno-style error code.</para>
   </refsect1>
 
   <refsect1>
     by returned. See <citerefentry><refentrytitle>sd_bus_send</refentrytitle><manvolnum>3</manvolnum></citerefentry>.</para>
   </refsect1>
 
-  <refsect1>
-    <title>Notes</title>
-
-    <para><function>sd_bus_open_user()</function> and the other
-    functions described here are available as a shared library, which
-    can be compiled and linked to with the
-    <constant>libsystemd</constant> <citerefentry
-    project='die-net'><refentrytitle>pkg-config</refentrytitle><manvolnum>1</manvolnum></citerefentry>
-    file.</para>
-  </refsect1>
+  <xi:include href="libsystemd-pkgconfig.xml" />
 
   <refsect1>
     <title>See Also</title>