-mdadm(8)                                                 mdadm(8)
-
-
-
-N\bNA\bAM\bME\bE
-       mdadm - manage MD devices _\ba_\bk_\ba Linux Software Raid.
-
-
-S\bSY\bYN\bNO\bOP\bPS\bSI\bIS\bS
-       m\bmd\bda\bad\bdm\bm _\b[_\bm_\bo_\bd_\be_\b] _\b<_\br_\ba_\bi_\bd_\bd_\be_\bv_\bi_\bc_\be_\b> _\b[_\bo_\bp_\bt_\bi_\bo_\bn_\bs_\b] _\b<_\bs_\bu_\bb_\bd_\be_\bv_\bi_\bc_\be_\bs_\b>
-
-
-D\bDE\bES\bSC\bCR\bRI\bIP\bPT\bTI\bIO\bON\bN
-       RAID  devices are virtual devices created from two or more
-       real block devices. This allows  multiple  devices  (typi-
-       cally  disk  drives or partitions there-of) to be combined
-       into a single  device  to  hold  (for  example)  a  single
-       filesystem.   Some  RAID levels included redundancy and so
-       can survive some degree of device failure.
-
-       Linux Software RAID devices are implemented through the md
-       (Multiple Devices) device driver.
-
-       Currently, Linux supports L\bLI\bIN\bNE\bEA\bAR\bR md devices, R\bRA\bAI\bID\bD0\b0 (strip-
-       ing), R\bRA\bAI\bID\bD1\b1 (mirroring), R\bRA\bAI\bID\bD4\b4 and R\bRA\bAI\bID\bD5\b5.\b.
-
-       Recent kernels (2002) also support a mode known as  M\bMU\bUL\bLT\bTI\bI-\b-
-       P\bPA\bAT\bTH\bH.  m\bmd\bda\bad\bdm\bm does not support MULTIPATH as yet.
-
-       m\bmd\bda\bad\bdm\bm is a program that can be used to create, manage, and
-       monitor MD devices.  As such it provides a similar set  of
-       functionality  to the r\bra\bai\bid\bdt\bto\boo\bol\bls\bs packages.  The key differ-
-       ences between m\bmd\bda\bad\bdm\bm and r\bra\bai\bid\bdt\bto\boo\bol\bls\bs are:
-
-       +\bo   m\bmd\bda\bad\bdm\bm is a single program and not a collection of pro-
-           grams.
-
-       +\bo   m\bmd\bda\bad\bdm\bm  can perform (almost) all of its functions with-
-           out having a configuration  file.   Also  mdadm  helps
-           with management of the configuration file.
-
-       +\bo   m\bmd\bda\bad\bdm\bm   can  provide  information  about  your  arrays
-           (through Detail and Examine) that r\bra\bai\bid\bdt\bto\boo\bol\bls\bs cannot.
-
-       +\bo   r\bra\bai\bid\bdt\bto\boo\bol\bls\bs can manage  MULTIPATH  devices  which  m\bmd\bda\bad\bdm\bm
-           cannot yet manage.
-
-
-M\bMO\bOD\bDE\bES\bS
-       mdadm has 7 major modes of operation:
-
-       A\bAs\bss\bse\bem\bmb\bbl\ble\be
-              Assemble  the  parts  of a previously created array
-              into an active array. Components can be  explicitly
-              given  or  can  be searched for.  m\bmd\bda\bad\bdm\bm checks that
-              the components do form a bona fide array, and  can,
-              on  request, fiddle superblock information so as to
-              assemble a faulty array.
-
-
-       B\bBu\bui\bil\bld\bd  Build   a   legacy   array    without    per-device
-              superblocks.
-
-
-       C\bCr\bre\bea\bat\bte\be Create a new array with per-device superblocks.
-
-
-       D\bDe\bet\bta\bai\bil\bl Display  the details of a given md device.  Details
-              include the RAID  level,  the  number  of  devices,
-              which ones are faulty (if any), and the array UUID.
-
-
-       E\bEx\bxa\bam\bmi\bin\bne\be
-              Examine a device to see if it  is  part  of  an  md
-              array,  and  print  out  the details of that array.
-              This mode can also be used to examine a large  num-
-              ber  of  devices  and to print out a summary of the
-              arrays  found  in  a  format   suitable   for   the
-              m\bmd\bda\bad\bdm\bm.\b.c\bco\bon\bnf\bf configuration file.
-
-
-       F\bFo\bol\bll\blo\bow\bw o\bor\br M\bMo\bon\bni\bit\bto\bor\br
-              Monitor one or more md devices and act on any state
-              changes.
-
-
-       M\bMa\ban\bna\bag\bge\be This  is  for  odd  bits  an  pieces  like  hotadd,
-              hotremove, setfaulty, stop, readonly, readwrite.
-
-
-O\bOP\bPT\bTI\bIO\bON\bNS\bS
-       Available options are:
-
-
-       -\b-A\bA, -\b--\b-a\bas\bss\bse\bem\bmb\bbl\ble\be
-              Assemble an existing array.
-
-
-       -\b-B\bB, -\b--\b-b\bbu\bui\bil\bld\bd
-              Build a legacy array without superblocks.
-
-
-       -\b-C\bC, -\b--\b-c\bcr\bre\bea\bat\bte\be
-              Create a new array.
-
-
-       -\b-D\bD, -\b--\b-d\bde\bet\bta\bai\bil\bl
-              Print detail of one or more md devices.
-
-
-       -\b-E\bE, -\b--\b-e\bex\bxa\bam\bmi\bin\bne\be
-              Print content of md superblock on device(s).
-
-
-       -\b-F\bF, -\b--\b-f\bfo\bol\bll\blo\bow\bw, -\b--\b-m\bmo\bon\bni\bit\bto\bor\br
-              Select M\bMo\bon\bni\bit\bto\bor\br mode.
-
-
-       -\b-h\bh, -\b--\b-h\bhe\bel\blp\bp
-              Display  help  message or, after above option, mode
-              specific help message.
-
-
-       -\b-V\bV, -\b--\b-v\bve\ber\brs\bsi\bio\bon\bn
-              Print version information for mdadm.
-
-
-       -\b-v\bv, -\b--\b-v\bve\ber\brb\bbo\bos\bse\be
-              Be more verbose about what is happening.
-
-
-       -\b-b\bb, -\b--\b-b\bbr\bri\bie\bef\bf
-              Be less verbose.  This is used  with  -\b--\b-d\bde\bet\bta\bai\bil\bl  and
-              -\b--\b-e\bex\bxa\bam\bmi\bin\bne\be.
-
-
-F\bFo\bor\br c\bcr\bre\bea\bat\bte\be o\bor\br b\bbu\bui\bil\bld\bd:\b:
-       -\b-c\bc, -\b--\b-c\bch\bhu\bun\bnk\bk=\b=
-              Specify  chunk  size  of kibibytes.  The default is
-              64.
-
-
-       -\b--\b-r\bro\bou\bun\bnd\bdi\bin\bng\bg=\b=
-              Specify rounding factor for linear  array  (==chunk
-              size)
-
-
-       -\b-l\bl, -\b--\b-l\ble\bev\bve\bel\bl=\b=
-              Set  raid  level.   Options  are: linear, raid0, 0,
-              stripe, raid1,  1,  mirror,  raid5,  4,  raid5,  5.
-              Obviously  some  of these are synonymous.  Only the
-              first 4 are valid when Building.
-
-
-       -\b-p\bp, -\b--\b-p\bpa\bar\bri\bit\bty\by=\b=
-              Set   raid5   parity   algorithm.   Options    are:
-              {left,right}-{,a}symmetric,  la,  ra,  ls, rs.  The
-              default is left-symmetric.
-
-
-       -\b--\b-l\bla\bay\byo\bou\but\bt=\b=
-              same as --parity
-
-
-       -\b-n\bn, -\b--\b-r\bra\bai\bid\bd-\b-d\bdi\bis\bsk\bks\bs=\b=
-              number of active devices in array.
-
-
-       -\b-x\bx, -\b--\b-s\bsp\bpa\bar\bre\be-\b-d\bdi\bis\bsk\bks\bs=\b=
-              number of spare (eXtra)  disks  in  initial  array.
-              Spares can be added and removed later.
-
-
-       -\b-z\bz, -\b--\b-s\bsi\biz\bze\be=\b=
-              Amount  (in  Kibibytes)  of  space to use from each
-              drive in RAID1/4/5.  This must be a multiple of the
-              chunk  size, and must leave about 128Kb of space at
-              the end of the drive for the RAID  superblock.   If
-              this  is  not specified (as it normally is not) the
-              smallest drive (or partition) sets the size, though
-              if  there is a variance among the drives of greater
-              than 1%, a warning is issued.
-
-
-F\bFo\bor\br a\bas\bss\bse\bem\bmb\bbl\ble\be:\b:
-       -\b-u\bu, -\b--\b-u\buu\bui\bid\bd=\b=
-              uuid of array to assemble. Devices which don't have
-              this uuid are excluded
-
-
-       -\b-m\bm, -\b--\b-s\bsu\bup\bpe\ber\br-\b-m\bmi\bin\bno\bor\br=\b=
-              Minor  number of device that array was created for.
-              Devices which don't  have  this  minor  number  are
-              excluded.  If you create an array as /dev/md1, then
-              all superblock will contain  the  minor  number  1,
-              even if the array is later assembled as /dev/md2.
-
-
-       -\b-c\bc, -\b--\b-c\bco\bon\bnf\bfi\big\bg=\b=
-              config file.  Default is /\b/e\bet\btc\bc/\b/m\bmd\bda\bad\bdm\bm.\b.c\bco\bon\bnf\bf.
-
-
-       -\b-s\bs, -\b--\b-s\bsc\bca\ban\bn
-              scan config file for missing information
-
-
-       -\b-f\bf, -\b--\b-f\bfo\bor\brc\bce\be
-              Assemble  the array even if some superblocks appear
-              out-of-date
-
-
-       -\b-R\bR, -\b--\b-r\bru\bun\bn
-              Attempt to start the array  even  if  fewer  drives
-              were  given  than are needed for a full array. Nor-
-              mally if not all drives are found and -\b--\b-s\bsc\bca\ban\bn is not
-              used,  then  the  array  will  be assembled but not
-              started.  With -\b--\b-r\bru\bun\bn an attempt  will  be  made  to
-              start it anyway.
-
-
-G\bGe\ben\bne\ber\bra\bal\bl m\bma\ban\bna\bag\bge\bem\bme\ben\bnt\bt
-       -\b-a\ba, -\b--\b-a\bad\bdd\bd
-              hotadd listed devices.
-
-
-       -\b-r\br, -\b--\b-r\bre\bem\bmo\bov\bve\be
-              remove  listed  devices.   The  must not be active.
-              i.e. they should be failed or spare devices.
-
-
-       -\b-f\bf, -\b--\b-f\bfa\bai\bil\bl
-              mark listed devices as faulty.
-
-
-       -\b--\b-s\bse\bet\bt-\b-f\bfa\bau\bul\blt\bty\by
-              same as --fail.
-
-
-       -\b-R\bR, -\b--\b-r\bru\bun\bn
-              start a partially built array.
-
-
-       -\b-S\bS, -\b--\b-s\bst\bto\bop\bp
-              deactivate array, releasing all resources.
-
-
-       -\b-o\bo, -\b--\b-r\bre\bea\bad\bdo\bon\bnl\bly\by
-              mark array as readonly.
-
-
-       -\b-w\bw, -\b--\b-r\bre\bea\bad\bdw\bwr\bri\bit\bte\be
-              mark array as readwrite.
-
-
-
-A\bAS\bSS\bSE\bEM\bMB\bBL\bLY\bY M\bMO\bOD\bDE\bE
-       Usage: m\bmd\bda\bad\bdm\bm -\b--\b-a\bas\bss\bse\bem\bmb\bbl\ble\be _\bd_\be_\bv_\bi_\bc_\be _\bo_\bp_\bt_\bi_\bo_\bn_\bs_\b._\b._\b.
-
-       Usage: m\bmd\bda\bad\bdm\bm -\b--\b-a\bas\bss\bse\bem\bmb\bbl\ble\be -\b--\b-s\bsc\bca\ban\bn _\bo_\bp_\bt_\bi_\bo_\bn_\bs_\b._\b._\b.
-
-
-       This usage assembles one or more  raid  arrays  from  pre-
-       existing  components.  For each array, mdadm needs to know
-       the md device, the identity of the array, and a number  of
-       sub devices. These can be found in a number of ways.
-
-       The  md  device  is either given before -\b--\b-s\bsc\bca\ban\bn or is found
-       from the config file. In  the  latter  case,  multiple  md
-       devices can be started with a single mdadm command.
-
-       The identity can be given with the -\b--\b-u\buu\bui\bid\bd option, with the
-       -\b--\b-s\bsu\bup\bpe\ber\br-\b-m\bmi\bin\bno\bor\br option, can be found in in the config  file,
-       or  will be taken from the super block on the first subde-
-       vice listed on the command line.
-
-       Devices can be given on the  -\b--\b-a\bas\bss\bse\bem\bmb\bbl\ble\be  command  line  or
-       from  the  config  file.  Only  devices  which  have an md
-       superblock which contains the right identity will be  con-
-       sidered for any device.
-
-       The  config  file  is  only  used if explicitly named with
-       -\b--\b-c\bco\bon\bnf\bfi\big\bg or requested with -\b--\b-s\bsc\bca\ban\bn.\b.   In  the  later  case,
-       /\b/e\bet\btc\bc/\b/m\bmd\bda\bad\bdm\bm.\b.c\bco\bon\bnf\bf is used.
-
-       If  -\b--\b-s\bsc\bca\ban\bn is not given, then the config file will only be
-       used to find the identity of md arrays.
-
-       Normally the array will be started after it is  assembled.
-       However  is  -\b--\b-s\bsc\bca\ban\bn  is  not given and insufficient drives
-       were lists to start a complete (non-degraded) array,  then
-       the  array is not started (to guard against usage errors).
-       To insist that the array be started in this case  (as  may
-       work for RAID1 or RAID5), give the -\b--\b-r\bru\bun\bn flag.
-
-
-
-B\bBU\bUI\bIL\bLD\bD M\bMO\bOD\bDE\bE
-       Usage:  m\bmd\bda\bad\bdm\bm  -\b--\b-b\bbu\bui\bil\bld\bd  _\bd_\be_\bv_\bi_\bc_\be -\b--\b-c\bch\bhu\bun\bnk\bk=\b=_\bX -\b--\b-l\ble\bev\bve\bel\bl=\b=_\bY -\b--\b-r\bra\bai\bid\bd-\b-
-                   d\bdi\bis\bsk\bks\bs=\b=_\bZ _\bd_\be_\bv_\bi_\bc_\be_\bs
-
-
-       This usage is similar to -\b--\b-c\bcr\bre\bea\bat\bte\be.  The difference is that
-       it creates a legacy array without a superblock. With these
-       arrays there is no difference between  initially  creating
-       the  array  and  subsequently assembling the array, except
-       that hopefully there is useful data there  in  the  second
-       case.
-
-       The  level  may  only  be 0, raid0, or linear. All devices
-       must be listed and the array will  be  started  once  com-
-       plete.
-
-
-C\bCR\bRE\bEA\bAT\bTE\bE M\bMO\bOD\bDE\bE
-       Usage: m\bmd\bda\bad\bdm\bm -\b--\b-c\bcr\bre\bea\bat\bte\be _\bd_\be_\bv_\bi_\bc_\be -\b--\b-c\bch\bhu\bun\bnk\bk=\b=_\bX -\b--\b-l\ble\bev\bve\bel\bl=\b=_\bY
-                   -\b--\b-r\bra\bai\bid\bd-\b-d\bdi\bis\bsk\bks\bs=\b=_\bZ _\bd_\be_\bv_\bi_\bc_\be_\bs
-
-
-       This  usage will initialise a new md array, associate some
-       devices with it, and activate the array.
-
-       As devices are added, they are checked to see if they con-
-       tain  raid superblocks or filesystems. They are also check
-       to see if the variance in device size exceeds 1%.
-
-       If any discrepancy is found, the array will not  automati-
-       cally  be run, though the presence of a -\b--\b-r\bru\bun\bn can override
-       this caution.
-
-
-       The General Management options that are valid with  --cre-
-       ate are:
-
-       -\b--\b-r\bru\bun\bn  insist  of  running  the array even if some devices
-              look like they might be in use.
-
-
-       -\b--\b-r\bre\bea\bad\bdo\bon\bnl\bly\by
-              start the array readonly - not supported yet.
-
-
-D\bDE\bET\bTA\bAI\bIL\bL M\bMO\bOD\bDE\bE
-       Usage: m\bmd\bda\bad\bdm\bm -\b--\b-d\bde\bet\bta\bai\bil\bl [-\b--\b-b\bbr\bri\bie\bef\bf] _\bd_\be_\bv_\bi_\bc_\be _\b._\b._\b.
-
-
-       This usage sill print out the details of the  given  array
-       including a list of component devices.  To determine names
-       for the devices, m\bmd\bda\bad\bdm\bm searches /\b/d\bde\bev\bv for device files with
-       the right major and minor numbers.
-
-       With  -\b--\b-b\bbr\bri\bie\bef\bf  m\bmd\bda\bad\bdm\bm  prints a single line that identifies
-       the level, number of disks, and UUID of the  array.   This
-       line is suitable for inclusion in /\b/e\bet\btc\bc/\b/m\bmd\bda\bad\bdm\bm.\b.c\bco\bon\bnf\bf.
-
-
-E\bEX\bXA\bAM\bMI\bIN\bNE\bE M\bMO\bOD\bDE\bE
-       Usage: m\bmd\bda\bad\bdm\bm -\b--\b-e\bex\bxa\bam\bmi\bin\bne\be [-\b--\b-s\bsc\bca\ban\bn] [-\b--\b-b\bbr\bri\bie\bef\bf] _\bd_\be_\bv_\bi_\bc_\be _\b._\b._\b.
-
-       This  usage will examine some block devices to see if that
-       have a valid RAID superblock on them.  The information  in
-       each valid raid superblock will be printed.
-
-       If  -\b--\b-s\bsc\bca\ban\bn  is  used, the no devices should be listed, and
-       the complete set of devices identified in  the  configura-
-       tion  file  are  checked.  -\b--\b-s\bsc\bca\ban\bn implies -\b--\b-b\bbr\bri\bie\bef\bf but this
-       implication can be countered by specifying -\b--\b-v\bve\ber\brb\bbo\bos\bse\be.
-
-       With -\b--\b-b\bbr\bri\bie\bef\bf m\bmd\bda\bad\bdm\bm will output an  config  file  entry  of
-       each  distinct array that was found.  This entry will list
-       the UUID, the raid level, and a  list  of  the  individual
-       devices  on  which  a superblock for that array was found.
-       This output will by syntactically suitable  for  inclusion
-       in the configuration file, but should N\bNO\bOT\bT be used blindly.
-       Often the array description that you want in the  configu-
-       ration file is much less specific than that given by m\bmd\bda\bad\bdm\bm
-       -\b-B\bBs\bs.  For example, you normally do not want  to  list  the
-       devices, particularly if they are SCSI devices.
-
-
-
-F\bFI\bIL\bLE\bES\bS
-   /\b/p\bpr\bro\boc\bc/\b/m\bmd\bds\bst\bta\bat\bt
-       If  you're  using the /\b/p\bpr\bro\boc\bc filesystem, /\b/p\bpr\bro\boc\bc/\b/m\bmd\bds\bst\bta\bat\bt gives
-       you informations about md devices status.   This  file  is
-       not currently used by m\bmd\bda\bad\bdm\bm.
-
-
-   /\b/e\bet\btc\bc/\b/m\bmd\bda\bad\bdm\bm.\b.c\bco\bon\bnf\bf
-       The  config file lists which devices may be scanned to see
-       if they contain MD  super  block,  and  gives  identifying
-       information  (e.g.  UUID)  about  known  MD  arrays.   See
-       m\bmd\bda\bad\bdm\bm.\b.c\bco\bon\bnf\bf(5) for more details.
-
-
-
-T\bTO\bOD\bDO\bO
-       Finish and document Follow mode.
-
-
-S\bSE\bEE\bE A\bAL\bLS\bSO\bO
-       For information on the various levels of RAID, check out:
-
-
-              http://ostenfeld.dk/~jakob/Software-RAID.HOWTO/
-
-       for new releases of the RAID driver check out:
-
-
-              ftp://ftp.kernel.org/pub/linux/kernel/peo-
-              ple/mingo/raid-patches
-
-       or
-
-              http://www.cse.unsw.edu.au/~neilb/patches/linux-
-              stable/
-
-       m\bmd\bda\bad\bdm\bm.\b.c\bco\bon\bnf\bf(5), m\bmd\bd(4).
-
-       _\br_\ba_\bi_\bd_\bt_\ba_\bb(5), _\br_\ba_\bi_\bd_\b0_\br_\bu_\bn(8), _\br_\ba_\bi_\bd_\bs_\bt_\bo_\bp(8), _\bm_\bk_\br_\ba_\bi_\bd(8)
-
-
-
-                                                         mdadm(8)