]> git.ipfire.org Git - ipfire-2.x.git/blobdiff - src/initscripts/init.d/nut
nut: move initscript to src/initscripts/packages and use new macro
[ipfire-2.x.git] / src / initscripts / init.d / nut
diff --git a/src/initscripts/init.d/nut b/src/initscripts/init.d/nut
deleted file mode 100644 (file)
index 9b4623e..0000000
+++ /dev/null
@@ -1,180 +0,0 @@
-#! /bin/sh
-
-PATH=/sbin:/usr/sbin:/bin:/usr/bin:/usr/local/sbin:/usr/local/bin
-
-NAME=nut
-DESC="Network UPS Tools"
-DEFAULT=/etc/sysconfig/nut
-CONFIG=/etc/nut/nut.conf
-
-. /etc/sysconfig/rc
-. $rc_functions
-
-# set upsd specific options. use "man upsd" for more info
-UPSD_OPTIONS=""
-
-# set upsmon specific options. use "man upsmon" for more info
-UPSMON_OPTIONS=""
-
-# Include defaults if available (transition period)
-if [ -f $DEFAULT ] ; then
-       . $DEFAULT
-fi
-
-# Include NUT nut.conf
-if [ -f $CONFIG ] ; then
-       . $CONFIG
-fi
-
-# Explicitly require the configuration to be done in /etc/nut/nut.conf
-if [ "x$MODE" = "xnone" ] ; then
-    log_failure_msg "$NAME disabled, please adjust the configuration to your needs "
-    log_failure_msg "and then set MODE to a suitable value in $CONFIG to enable it."
-    # exit success to avoid breaking the install process!
-    exit 0
-fi
-
-upsd=/usr/sbin/upsd
-upsdrvctl=/usr/sbin/upsdrvctl
-upsmon=/usr/sbin/upsmon
-log=">/dev/null 2>/dev/null"
-
-start_stop_server () {
-  case "$MODE" in
-    standalone|netserver)
-      case "$1" in
-        start)
-          ! $upsdrvctl start >/dev/null 2>&1 && boot_mesg "(upsdrvctl failed)"
-          $upsd $UPSD_OPTIONS >/dev/null 2>&1
-          evaluate_retval
-          ;;
-        stop)
-          $upsd -c stop >/dev/null 2>&1
-          evaluate_retval
-          ! $upsdrvctl stop >/dev/null 2>&1 && boot_mesg "(upsdrvctl failed)"
-          ;;
-      esac
-      ;;
-    none|netclient|*)
-      return 1
-      ;;
-  esac
-}
-
-start_stop_client () {
-  case "$MODE" in
-    standalone|netserver|netclient)
-      case "$1" in
-        start)
-          $upsmon $UPSMON_OPTIONS >/dev/null 2>&1
-          evaluate_retval
-          ;;
-        stop)
-          $upsmon -c stop >/dev/null 2>&1
-          evaluate_retval
-          ;;
-      esac
-      ;;
-    none|*)
-      return 1
-      ;;
-  esac
-}
-
-status_server () {
-  case "$MODE" in
-    standalone|netserver)
-      statusproc $upsd
-      statusproc $upsmon
-      ;;
-    none|netclient|*)
-      return 1
-      ;;
-  esac
-}
-
-status_client () {
-  case "$MODE" in
-    standalone|netclient)
-      statusproc $upsmon
-      ;;
-    none|*)
-      return 1
-      ;;
-  esac
-}
-
-case "$1" in
-
-  start)
-    boot_mesg "Starting $DESC ..."
-    start_stop_server start
-    start_stop_client start
-    ;;
-
-  stop)
-    boot_mesg "Stopping $DESC ..."
-    start_stop_server stop
-    start_stop_client stop
-    ;;
-
-  reload)
-    $upsd   -c reload >/dev/null 2>&1
-    $upsmon -c reload >/dev/null 2>&1
-    ;;
-
-  status)
-    status_server
-    status_client
-    ;;
-
-  restart|force-reload)
-    boot_mesg "Restarting $DESC ..."
-    start_stop_client stop
-    start_stop_server stop
-    sleep 5
-    start_stop_server start
-    start_stop_client start
-    ;;
-
-  poweroff)
-    flag=`sed -ne 's#^ *POWERDOWNFLAG *\(.*\)$#\1#p' /etc/nut/upsmon.conf`
-    wait_delay=`sed -ne 's#^ *POWEROFF_WAIT= *\(.*\)$#\1#p' $CONFIG`
-    if [ -f "$flag" ] ; then
-      if $upsmon -K >/dev/null 2>&1 ; then
-       boot_mesg "Shutting down the UPS ..."
-       sleep 1
-       if $upsdrvctl shutdown ; then
-         sleep 5
-         boot_mesg "Waiting for UPS to cut the power"
-       else
-         boot_mesg "Shutdown failed."
-         boot_mesg "Waiting for UPS batteries to run down"
-       fi
-       if [ "$wait_delay" ] ; then
-         boot_mesg " (will reboot after $wait_delay) ..."
-         sleep "$wait_delay"
-         /etc/init.d/reboot stop
-       fi
-      else
-        boot_mesg "Power down flag is not set (UPS shutdown not needed)"
-      fi
-    else
-        if [ -z "$flag" ] ; then
-         boot_mesg "##########################################################"
-         boot_mesg "## POWERDOWNFLAG is not defined in /etc/nut/upsmon.conf ##"
-         boot_mesg "##                                                      ##"
-         boot_mesg "## Please read the Manual page upsmon.conf(5)           ##"
-         boot_mesg "##########################################################"
-       fi
-    fi
-    ;;
-
-  *)
-    N=/etc/init.d/$NAME
-    echo "Usage: $N {start|stop|status|reload|restart|force-reload|poweroff}" >&2
-    exit 1
-    ;;
-esac
-
-exit 0