]> git.ipfire.org Git - thirdparty/cups.git/blame - CHANGES.md
Fix crash when AccessLog is NULL (Issue #5309)
[thirdparty/cups.git] / CHANGES.md
CommitLineData
91505c0a 1CHANGES - 2.3b6 - 2018-06-18
050d2657 2============================
d07cb8d5 3
39897200
MS
4Changes in CUPS v2.3b6
5----------------------
6
dc0b986f 7- Localization update (Issue #5339)
997b6734
MS
8- The lpadmin command would create a non-working printer in some error cases
9 (Issue #5305)
9dcb503f
MS
10- The scheduler would crash if an empty `AccessLog` directive was specified
11 (Issue #5309)
9fc5c8d4 12- The scheduler did not idle-exit on some Linux distributions (Issue #5319)
1d677f11
MS
13- Fixed a regression in the changes to ippValidateAttribute (Issue #5322,
14 Issue #5330)
7e041a5e 15- Fixed a crash bug in the Epson dot matrix driver (Issue #5323)
553f29c9 16- The web interface did not list the IPP Everywhere "driver" (Issue #5338)
91505c0a
MS
17- The scheduler did not report all of the supported job options and values
18 (Issue #5340)
39897200
MS
19- Fixed a memory leak for some IPP (extension) syntaxes.
20
21
8eed4387 22Changes in CUPS v2.3b5
39897200 23----------------------
d07cb8d5
MS
24
25- The `ipptool` program no longer checks for duplicate attributes when running
26 in list or CSV mode (Issue #5278)
159e0279
MS
27- The `cupsCreateJob`, `cupsPrintFile2`, and `cupsPrintFiles2` APIs did not use
28 the supplied HTTP connection (Issue #5288)
656c109a
MS
29- Fixed another crash in the scheduler when adding an IPP Everywhere printer
30 (Issue #5290)
4feb1fe2
MS
31- Added a workaround for certain web browsers that do not support multiple
32 authentication schemes in a single response header (Issue #5289)
0873f681 33- Fixed policy limits containing the `All` operation (Issue #5296)
bd4b5b3e 34- The scheduler was always restarted after idle-exit with systemd (Issue #5297)
050d2657 35- Added a USB quirks rule for the HP LaserJet P1102 (Issue #5310)
2de7c5f8 36- The mailto notifier did not wait for the welcome message (Issue #5312)
0541a2c9 37- Fixed a parsing bug in the pstops filter (Issue #5321)
dfe5f3b9 38- Documentation updates (Issue #5299, Issue #5301, Issue #5306)
b27f4108 39- Localization updates (Issue #5317)
53f84044
MS
40- The scheduler allowed environment variables to be specified in the
41 `cupsd.conf` file (rdar://37836779, rdar://37836995, rdar://37837252,
42 rdar://37837581)
fbcc927d
MS
43- Fax queues did not support pause (p) or wait-for-dialtone (w) characters
44 (rdar://39212256)
be7581b6
MS
45- The scheduler did not validate notify-recipient-uri values properly
46 (rdar://40068936)
8eed4387 47- The IPP parser allowed invalid group tags (rdar://40442124)
44cb0dd2 48- Fixed a parsing bug in the new authentication code.
d07cb8d5 49
2a20b512 50
63f8dcbd
MS
51Changes in CUPS v2.3b4
52----------------------
ab89234d 53
b25f3cf0 54- NOTICE: Printer drivers are now deprecated (Issue #5270)
0fea1812
MS
55- Kerberized printing to another CUPS server did not work correctly
56 (Issue #5233)
e6062e8e 57- Fixed printing to some IPP Everywhere printers (Issue #5238)
ab89234d 58- Fixed installation of filters (Issue #5247)
19186c8b
MS
59- The scheduler now supports using temporary print queues for older IPP/1.1
60 print queues like those shared by CUPS 1.3 and earlier (Issue #5241)
c6dbbca1
MS
61- Star Micronics printers need the "unidir" USB quirk rule (Issue #5251)
62- Documentation fixes (Issue #5252)
3cd7b5e0 63- Fixed a compile issue when PAM is not available (Issue #5253)
c6dbbca1
MS
64- Label printers supported by the rastertolabel driver don't support SNMP, so
65 don't delay printing to test it (Issue #5256)
ca75cc13 66- The scheduler could crash while adding an IPP Everywhere printer (Issue #5258)
c6dbbca1
MS
67- The Lexmark Optra E310 printer needs the "no-reattach" USB quirk rule
68 (Issue #5259)
0dfe6990
MS
69- Systemd did not restart cupsd when configuration changes were made that
70 required a restart (Issue #5263)
8aecb229
MS
71- The IPP Everywhere PPD generator did not include the `cupsJobPassword`
72 keyword, when supported (Issue #5265)
6a76f435 73- Fixed an Avahi crash bug in the scheduler (Issue #5268)
003c1790 74- Raw print queues are now deprecated (Issue #5269)
b056061b 75- Fixed an RPM packaging problem (Issue #5276)
fe1a4305 76- The IPP backend did not properly detect failed PDF prints (rdar://34055474)
eb61cb5b 77- TLS connections now properly timeout (rdar://34938533)
0bb02bfa
MS
78- Temp files could not be created in some sandboxed applications
79 (rdar://37789645)
c64170e5
MS
80- The ipptool `--ippserver` option did not encode out-of-band attributes
81 correctly.
c65e1c4f
MS
82- Added public `cupsEncodeOption` API for encoding a single option as an IPP
83 attribute.
0fb02fb9
MS
84- Removed support for the `-D_PPD_DEPRECATED=""` developer cheat - the PPD API
85 should no longer be used.
86- Removed support for `-D_IPP_PRIVATE_STRUCTURES=1` developer cheat - the IPP
87 accessor functions should be used instead.
ab89234d
MS
88
89
c283f46d
MS
90Changes in CUPS v2.3b3
91----------------------
92
f6e7a0c5 93- More fixes for printing to old CUPS servers (Issue #5211)
c283f46d
MS
94- The IPP Everywhere PPD generator did not support deep grayscale or 8-bit per
95 component AdobeRGB (Issue #5227)
092db1e2
MS
96- Additional changes for the scheduler to substitute default values for invalid
97 job attributes when running in "relaxed conformance" mode (Issue #5229)
f6e7a0c5 98- Localization changes (Issue #5232, rdar://37068158)
22974c5f
MS
99- The `cupsCopyDestInfo` function did not work with all print queues
100 (Issue #5235)
c283f46d 101
bea37134 102
e1613057
MS
103Changes in CUPS v2.3b2
104----------------------
105
ead6e488
MS
106- Localization changes (Issue #5210)
107- Build fixes (Issue #5217)
a8b28f18 108- IPP Everywhere PPDs were not localized to English (Issue #5205)
625bb9de
MS
109- The `cupsGetDests` and `cupsEnumDests` functions no longer filter out local
110 print services like IPP USB devices (Issue #5206)
3145b7e6
MS
111- The `cupsCopyDest` function now correctly copies the `is_default` value
112 (Issue #5208)
6a3d63e6 113- Printing to old CUPS servers has been fixed (Issue #5211)
e1613057 114- The `ppdInstallableConflict` tested too many constraints (Issue #5213)
378eeedf
MS
115- All HTTP field values can now be longer than `HTTP_MAX_VALUE` bytes
116 (Issue #5216)
43bcc47b 117- Added a USB quirk rule for Canon MP280 series printers (Issue #5221)
7c91db71
MS
118- The `cupsRasterWritePixels` function did not correctly swap bytes for some
119 formats (Issue #5225)
117bf0d1 120- Fixed an issue with mapping finishing options (rdar://34250727)
4ef3ee37
MS
121- The `ppdLocalizeIPPReason` function incorrectly returned a localized version
122 of "none" (rdar://36566269)
c4faa907
MS
123- The scheduler did not add ".local" to the default DNS-SD host name when
124 needed.
e1613057
MS
125
126
11143dcf 127Changes in CUPS v2.3b1
bea37134
MS
128----------------------
129
e3101897 130- CUPS is now provided under the Apache License, Version 2.0.
67091b1b 131- Documentation updates (Issue #4580, Issue #5177, Issue #5192)
336b669e
MS
132- The `cupsCopyDestConflicts` function now handles collection attribute
133 ("media-col", "finishings-col", etc.) constraints (Issue #4096)
42a5ae2a 134- The `lpoptions` command incorrectly saved default options (Issue #4717)
d6db9ea1 135- The `lpstat` command now reports when new jobs are being held (Issue #4761)
d5621649
MS
136- The `ippfind` command now supports finding printers whose name starts with an
137 underscore (Issue #4833)
7ec11630
MS
138- The CUPS library now supports the latest HTTP Digest authentication
139 specification including support for SHA-256 (Issue #4862)
409f5497 140- The scheduler now supports the "printer-id" attribute (Issue #4868)
f1547f12
MS
141- No longer support backslash, question mark, or quotes in printer names
142 (Issue #4966)
3d468ced
MS
143- The scheduler no longer logs pages as they are printed, instead just logging
144 a total of the pages printed at job completion (Issue #4991)
b00c8409 145- Dropped RSS subscription management from the web interface (Issue #5012)
c5d2b233
MS
146- Bonjour printer sharing now uses the DNS-SD hostname (or ServerName value if
147 none is defined) when registering shared printers on the network (Issue #5071)
6646208b
MS
148- The `ipptool` command now supports writing `ippserver` attributes files
149 (Issue #5093)
d6db9ea1
MS
150- The `lp` and `lpr` commands now provide better error messages when the default
151 printer cannot be found (Issue #5096)
152- The `lpadmin` command now provides a better error message when an unsupported
d0df9cd3 153 System V interface script is used (Issue #5111)
eb2cb9b0
MS
154- The scheduler did not write out dirty configuration and state files if there
155 were open client connections (Issue #5118)
8f1fbdec
MS
156- The `SSLOptions` directive now supports `MinTLS` and `MaxTLS` options to
157 control the minimum and maximum TLS versions that will be allowed,
158 respectively (Issue #5119)
b00c8409 159- Dropped hard-coded CGI scripting language support (Issue #5124)
c5f5c5a7
MS
160- The `cupsEnumDests` function did not include options from the lpoptions
161 files (Issue #5144)
d6db9ea1 162- Fixed the `ippserver` sample code when threading is disabled or unavailable
98491ecc 163 (Issue #5154)
0e743fdf
MS
164- Added label markup to checkbox and radio button controls in the web interface
165 templates (Issue #5161)
da9ffe23 166- Fixed group validation on OpenBSD (Issue #5166)
71dc43af
MS
167- Improved IPP Everywhere media support, including a new
168 `cupsAddDestMediaOptions` function (Issue #5167)
89550f3f
MS
169- IPP Everywhere PPDs now include localizations of printer-specific media types,
170 when available (Issue #5168)
7f9a23b9
MS
171- The cups-driverd program incorrectly stopped scanning PPDs as soon as a loop
172 was seen (Issue #5170)
cfa8aa69 173- IPP Everywhere PPDs now support IPP job presets (Issue #5179)
4f63d6cd 174- IPP Everywhere PPDs now support finishing templates (Issue #5180)
7e382613 175- Fixed a journald support bug in the scheduler (Issue #5181)
ac05c630
MS
176- Fixed PAM module detection and added support for the common PAM definitions
177 (Issue #5185)
6d14c1bb
MS
178- The scheduler now substitutes default values for invalid job attributes when
179 running in "relaxed conformance" mode (Issue #5186)
9e44dfbe 180- The scheduler did not work with older versions of uClibc (Issue #5188)
2fa1ba3c
MS
181- The scheduler now generates a strings file for localizing PPD options
182 (Issue #5194)