Commit | Line | Data |
---|---|---|
1a0e562a ZJS |
1 | <?xml version='1.0'?> |
2 | <!DOCTYPE refentry PUBLIC "-//OASIS//DTD DocBook XML V4.5//EN" | |
3 | "http://www.oasis-open.org/docbook/xml/4.2/docbookx.dtd" > | |
4 | <!-- SPDX-License-Identifier: LGPL-2.1+ --> | |
5 | ||
6 | <refentry id="org.freedesktop.LogControl1" | |
7 | xmlns:xi="http://www.w3.org/2001/XInclude"> | |
8 | <refentryinfo> | |
9 | <title>org.freedesktop.LogControl1</title> | |
10 | <productname>systemd</productname> | |
11 | </refentryinfo> | |
12 | ||
13 | <refmeta> | |
14 | <refentrytitle>org.freedesktop.LogControl1</refentrytitle> | |
15 | <manvolnum>5</manvolnum> | |
16 | </refmeta> | |
17 | ||
18 | <refnamediv> | |
19 | <refname>org.freedesktop.LogControl1</refname> | |
20 | <refpurpose>D-Bus interface to query and set logging configuration</refpurpose> | |
21 | </refnamediv> | |
22 | ||
23 | <refsect1> | |
24 | <title>Introduction</title> | |
25 | ||
26 | <para><interfacename>org.freedesktop.LogControl1</interfacename> is a generic interface that is intended | |
27 | to be used by any daemon which should allow setting the log level and target over D-Bus. It is implemented | |
28 | by various daemons that are part of the | |
29 | <citerefentry><refentrytitle>systemd</refentrytitle><manvolnum>1</manvolnum></citerefentry> suite.</para> | |
30 | ||
31 | <para>It is assumed that those settings are global for the whole program, so a fixed object path is | |
32 | used. The interface should always be available under the path | |
33 | <filename>/org/freedesktop/LogControl1</filename>.</para> | |
34 | </refsect1> | |
35 | ||
36 | <refsect1> | |
37 | <title>Description</title> | |
38 | ||
39 | <para>The following interface is exposed:</para> | |
40 | ||
41 | <programlisting executable="systemd" node="/org/freedesktop/LogControl1" interface="org.freedesktop.LogControl1"> | |
42 | node /org/freedesktop/LogControl1 { | |
43 | interface org.freedesktop.LogControl1 { | |
44 | properties: | |
45 | @org.freedesktop.DBus.Property.EmitsChangedSignal("false") | |
46 | @org.freedesktop.systemd1.Privileged("true") | |
47 | readwrite s LogLevel = '...'; | |
48 | @org.freedesktop.DBus.Property.EmitsChangedSignal("false") | |
49 | @org.freedesktop.systemd1.Privileged("true") | |
50 | readwrite s LogTarget = '...'; | |
51 | @org.freedesktop.DBus.Property.EmitsChangedSignal("false") | |
52 | readonly s SyslogIdentifier = '...'; | |
53 | }; | |
54 | interface org.freedesktop.DBus.Peer { ... }; | |
55 | interface org.freedesktop.DBus.Introspectable { ... }; | |
56 | interface org.freedesktop.DBus.Properties { ... }; | |
57 | }; | |
58 | </programlisting> | |
59 | ||
60 | <!--Autogenerated cross-references for systemd.directives, do not edit--> | |
61 | ||
62 | <variablelist class="dbus-interface" generated="True" extra-ref="org.freedesktop.LogControl1"/> | |
63 | ||
64 | <variablelist class="dbus-interface" generated="True" extra-ref="org.freedesktop.LogControl1"/> | |
65 | ||
66 | <variablelist class="dbus-property" generated="True" extra-ref="LogLevel"/> | |
67 | ||
68 | <variablelist class="dbus-property" generated="True" extra-ref="LogTarget"/> | |
69 | ||
70 | <variablelist class="dbus-property" generated="True" extra-ref="SyslogIdentifier"/> | |
71 | ||
72 | <!--End of Autogenerated section--> | |
73 | ||
74 | <refsect2> | |
75 | <title>Properties</title> | |
76 | ||
77 | <para><varname>LogLevel</varname> describes the | |
b7a47345 | 78 | <citerefentry project='man-pages'><refentrytitle>syslog</refentrytitle><manvolnum>3</manvolnum></citerefentry>-style |
1a0e562a ZJS |
79 | log-level, and should be one of <literal>emerg</literal>, <literal>alert</literal>, |
80 | <literal>crit</literal>, <literal>err</literal>, <literal>warning</literal>, <literal>notice</literal>, | |
81 | <literal>info</literal>, <literal>debug</literal>, in order of increasing verbosity.</para> | |
82 | ||
83 | <para><varname>LogTarget</varname> describes the log target (mechanism). It should be one of | |
84 | <literal>console</literal> (log to the console or standard output), | |
85 | <literal>kmsg</literal> (log to the kernel ring buffer), | |
37b22b3b | 86 | <literal>journal</literal> (log to the journal natively, see |
1a0e562a ZJS |
87 | <citerefentry><refentrytitle>systemd-journald.service</refentrytitle><manvolnum>8</manvolnum></citerefentry>), |
88 | <literal>syslog</literal> (log using the | |
b7a47345 | 89 | <citerefentry project='man-pages'><refentrytitle>syslog</refentrytitle><manvolnum>3</manvolnum></citerefentry> call). |
1a0e562a ZJS |
90 | </para> |
91 | ||
92 | <para>Those two properties are writable, so they may be set by sufficiently privileged users.</para> | |
93 | ||
94 | <para><varname>SyslogIdentifier</varname> is a read-only property that shows the "syslog identifier". | |
95 | It is a short string that identifies the program that is the source of log messages that is passed to | |
b7a47345 | 96 | the <citerefentry project='man-pages'><refentrytitle>syslog</refentrytitle><manvolnum>3</manvolnum></citerefentry> call. |
1a0e562a ZJS |
97 | </para> |
98 | ||
99 | <para>Note: <command>journalctl</command> option <option>-p</option>/<option>--priority=</option> may | |
100 | be used to filter log messages by log level, option <option>-t</option>/<option>--identifier=</option> | |
101 | may be used to by the syslog identifier, and filters like <literal>_TRANSPORT=syslog</literal>, | |
102 | <literal>_TRANSPORT=journal</literal>, and <literal>_TRANSPORT=kernel</literal> may be used to filter | |
103 | messages by the mechanism through which they reached <command>systemd-journald</command>.</para> | |
104 | </refsect2> | |
105 | </refsect1> | |
106 | </refentry> |