1 From c47aacc67a3d26dfab9c9b8965975ed2b2010b30 Mon Sep 17 00:00:00 2001
2 From: Marko Hänninen <bugitus@gmail.com>
3 Date: Fri, 31 Jul 2009 22:32:39 +0300
4 Subject: USB: ftdi_sio: add vendor and product id for Bayer glucose meter serial converter cable
5
6 From: Marko Hänninen <bugitus@gmail.com>
7
8 commit c47aacc67a3d26dfab9c9b8965975ed2b2010b30 upstream.
9
10 Attached patch adds USB vendor and product IDs for Bayer's USB to serial
11 converter cable used by Bayer blood glucose meters. It seems to be a
12 FT232RL based device and works without any problem with ftdi_sio driver
13 when this patch is applied. See: http://winglucofacts.com/cables/
14
15
16 Signed-off-by: Marko Hänninen <bugitus@gmail.com>
17 Signed-off-by: Greg Kroah-Hartman <gregkh@suse.de>
18
19 ---
20 drivers/usb/serial/ftdi_sio.c | 1 +
21 drivers/usb/serial/ftdi_sio.h | 7 +++++++
22 2 files changed, 8 insertions(+)
23
24 --- a/drivers/usb/serial/ftdi_sio.c
25 +++ b/drivers/usb/serial/ftdi_sio.c
26 @@ -663,6 +663,7 @@ static struct usb_device_id id_table_com
27 { USB_DEVICE(ADI_VID, ADI_GNICE_PID),
28 .driver_info = (kernel_ulong_t)&ftdi_jtag_quirk },
29 { USB_DEVICE(JETI_VID, JETI_SPC1201_PID) },
30 + { USB_DEVICE(BAYER_VID, BAYER_CONTOUR_CABLE_PID) },
31 { }, /* Optional parameter entry */
32 { } /* Terminating entry */
33 };
34 --- a/drivers/usb/serial/ftdi_sio.h
35 +++ b/drivers/usb/serial/ftdi_sio.h
36 @@ -897,6 +897,13 @@
37 #define JETI_SPC1201_PID 0x04b2
38
39 /*
40 + * Bayer Ascensia Contour blood glucose meter USB-converter cable.
41 + * http://winglucofacts.com/cables/
42 + */
43 +#define BAYER_VID 0x1A79
44 +#define BAYER_CONTOUR_CABLE_PID 0x6001
45 +
46 +/*
47 * BmRequestType: 1100 0000b
48 * bRequest: FTDI_E2_READ
49 * wValue: 0