# IPFire.org - A linux based firewall #
-# Copyright (C) 2007-2016 IPFire Team <info@ipfire.org> #
+# Copyright (C) 2007-2020 IPFire Team <info@ipfire.org> #
# #
# This program is free software: you can redistribute it and/or modify #
# it under the terms of the GNU General Public License as published by #
# You should have received a copy of the GNU General Public License #
# along with this program. If not, see <http://www.gnu.org/licenses/>. #
# #
-###############################################################################
###############################################################################
# Definitions
done
chmod 644 /etc/rc.d/init.d/functions
- for i in $(DIR_SRC)/src/initscripts/init.d/networking/*; do \
+ for i in $(DIR_SRC)/src/initscripts/networking/*; do \
if [ -f $$i ]; then \
install -v -m 754 $$i /etc/rc.d/init.d/networking/; \
fi; \
done
- for i in $(DIR_SRC)/src/initscripts/init.d/networking/red.up/*; do \
+ for i in $(DIR_SRC)/src/initscripts/networking/red.up/*; do \
install -v -m 754 $$i /etc/rc.d/init.d/networking/red.up/; \
done
- for i in $(DIR_SRC)/src/initscripts/init.d/networking/red.down/*; do \
+ for i in $(DIR_SRC)/src/initscripts/networking/red.down/*; do \
install -v -m 754 $$i /etc/rc.d/init.d/networking/red.down/; \
done
ln -sf ../init.d/messagebus /etc/rc.d/rc3.d/S15messagebus
ln -sf ../init.d/messagebus /etc/rc.d/rc0.d/K85messagebus
ln -sf ../init.d/messagebus /etc/rc.d/rc6.d/K85messagebus
- ln -sf ../init.d/bluetooth /etc/rc.d/rc3.d/S16bluetooth
- ln -sf ../init.d/bluetooth /etc/rc.d/rc0.d/K84bluetooth
- ln -sf ../init.d/bluetooth /etc/rc.d/rc6.d/K84bluetooth
ln -sf ../init.d/cpufreq /etc/rc.d/rc3.d/S18cpufreq
ln -sf ../init.d/sysklogd /etc/rc.d/rc6.d/K90sysklogd
ln -sf ../init.d/sendsignals /etc/rc.d/rc6.d/S60sendsignals
ln -sf ../init.d/fcron /etc/rc.d/rc0.d/K08fcron
ln -sf ../init.d/fcron /etc/rc.d/rc3.d/S40fcron
ln -sf ../init.d/fcron /etc/rc.d/rc6.d/K08fcron
- ln -sf ../init.d/snort /etc/rc.d/rc0.d/K78snort
- ln -sf ../init.d/snort /etc/rc.d/rc6.d/K78snort
+ ln -sf ../init.d/suricata /etc/rc.d/rc0.d/K78suricata
+ ln -sf ../init.d/suricata /etc/rc.d/rc6.d/K78suricata
ln -sf ../init.d/network /etc/rc.d/rc0.d/K80network
ln -sf ../init.d/network /etc/rc.d/rc3.d/S20network
ln -sf ../init.d/network /etc/rc.d/rc6.d/K80network
- ln -sf ../init.d/unbound /etc/rc.d/rc0.d/K79unbound
+ ln -sf ../init.d/unbound /etc/rc.d/rc0.d/K86unbound
ln -sf ../init.d/unbound /etc/rc.d/rc3.d/S11unbound
- ln -sf ../init.d/unbound /etc/rc.d/rc6.d/K79unbound
- ln -sf ../init.d/random /etc/rc.d/rc0.d/K45random
- ln -sf ../init.d/random /etc/rc.d/rc3.d/S25random
- ln -sf ../init.d/random /etc/rc.d/rc6.d/K45random
+ ln -sf ../init.d/unbound /etc/rc.d/rc6.d/K86unbound
ln -sf ../../sysconfig/rc.local /etc/rc.d/rc3.d/S98rc.local
- ln -sf ../init.d/mediatomb /etc/rc.d/rc3.d/S98mediatomb
- ln -sf ../init.d/mediatomb /etc/rc.d/rc0.d/K02mediatomb
- ln -sf ../init.d/mediatomb /etc/rc.d/rc6.d/K02mediatomb
ln -sf ../init.d/client175 /etc/rc.d/rc0.d/K34client175
ln -sf ../init.d/client175 /etc/rc.d/rc3.d/S66client175
ln -sf ../init.d/client175 /etc/rc.d/rc6.d/K34client175
ln -sf ../init.d/leds /etc/rc.d/rc3.d/S21leds
ln -sf ../init.d/leds /etc/rc.d/rc6.d/K79leds
ln -sf ../init.d/fireinfo /etc/rc.d/rc3.d/S15fireinfo
+ ln -sf ../init.d/conntrackd /etc/rc.d/rc0.d/K77conntrackd
+ ln -sf ../init.d/conntrackd /etc/rc.d/rc3.d/S22conntrackd
+ ln -sf ../init.d/conntrackd /etc/rc.d/rc6.d/K77conntrackd
ln -sf ../init.d/mountkernfs /etc/rc.d/rcsysinit.d/S00mountkernfs
ln -sf ../init.d/sysctl /etc/rc.d/rcsysinit.d/S01sysctl
ln -sf ../init.d/modules /etc/rc.d/rcsysinit.d/S05modules
+ ln -sf ../init.d/lvmetad /etc/rc.d/rcsysinit.d/S09lvmetad
ln -sf ../init.d/udev /etc/rc.d/rcsysinit.d/S10udev
ln -sf ../init.d/waitdrives /etc/rc.d/rcsysinit.d/S19waitdrives
- ln -sf ../init.d/swap /etc/rc.d/rcsysinit.d/S20swap
ln -sf ../init.d/partresize /etc/rc.d/rcsysinit.d/S25partresize
ln -sf ../init.d/checkfs /etc/rc.d/rcsysinit.d/S30checkfs
ln -sf ../init.d/mountfs /etc/rc.d/rcsysinit.d/S40mountfs
+ ln -sf ../init.d/swap /etc/rc.d/rcsysinit.d/S41swap
ln -sf ../init.d/fsresize /etc/rc.d/rcsysinit.d/S42fsresize
ln -sf ../init.d/mounttmpfs /etc/rc.d/rcsysinit.d/S43mounttmpfs
+ ln -sf ../init.d/smt /etc/rc.d/rcsysinit.d/S44smt
ln -sf ../init.d/udev_retry /etc/rc.d/rcsysinit.d/S45udev_retry
ln -sf ../init.d/cleanfs /etc/rc.d/rcsysinit.d/S50cleanfs
ln -sf ../init.d/setclock /etc/rc.d/rcsysinit.d/S60setclock
ln -sf ../init.d/setclock /etc/rc.d/rc0.d/K47setclock
ln -sf ../init.d/setclock /etc/rc.d/rc6.d/K47setclock
+ ln -sf ../init.d/rngd /etc/rc.d/rcsysinit.d/S65rngd
+ ln -sf ../init.d/random /etc/rc.d/rcsysinit.d/S66random
ln -sf ../init.d/console /etc/rc.d/rcsysinit.d/S70console
+ ln -sf ../init.d/pakfire /etc/rc.d/rcsysinit.d/S71pakfire
+ ln -sf ../init.d/cloud-init /etc/rc.d/rcsysinit.d/S74cloud-init
ln -sf ../init.d/firstsetup /etc/rc.d/rcsysinit.d/S75firstsetup
ln -sf ../init.d/localnet /etc/rc.d/rcsysinit.d/S80localnet
ln -sf ../init.d/firewall /etc/rc.d/rcsysinit.d/S85firewall
- ln -sf ../init.d/network-trigger /etc/rc.d/rcsysinit.d/S90network-trigger
- ln -sf ../init.d/rngd /etc/rc.d/rcsysinit.d/S92rngd
ln -sf ../init.d/vnstat /etc/rc.d/rc3.d/S01vnstat
ln -sf ../init.d/vnstat /etc/rc.d/rc0.d/K51vnstat
ln -sf ../init.d/vnstat /etc/rc.d/rc6.d/K51vnstat
ln -sf ../init.d/wlanclient /etc/rc.d/rc3.d/S19wlanclient
ln -sf ../init.d/wlanclient /etc/rc.d/rc6.d/K82wlanclient
- ln -sf ../../../../../usr/local/bin/snortctrl \
- /etc/rc.d/init.d/networking/red.up/23-RS-snort
ln -sf ../../../../../usr/local/bin/qosctrl \
/etc/rc.d/init.d/networking/red.up/24-RS-qos
ln -sf ../../squid /etc/rc.d/init.d/networking/red.up/27-RS-squid
ln -sf any /etc/rc.d/init.d/networking/$$i; \
done
- # ARM does not need acpid, intel no swconfig
-ifeq "$(MACHINE_TYPE)" "arm"
- rm -vf /etc/rc.d/init.d/acpid
+ # intel intel no swconfig
+ifeq "$(BUILD_PLATFORM)" "arm"
ln -sf ../init.d/swconfig /etc/rc.d/rcsysinit.d/S73swconfig
else
rm -vf /etc/rc.d/init.d/swconfig
+endif
ln -sf ../init.d/acpid /etc/rc.d/rc3.d/S12acpid
ln -sf ../init.d/acpid /etc/rc.d/rc0.d/K87acpid
ln -sf ../init.d/acpid /etc/rc.d/rc6.d/K87acpid
-endif
-
@$(POSTBUILD)