hw/timer/imx_epit: remove explicit fields cnt and freq
The CNT register is a read-only register. There is no need to
store it's value, it can be calculated on demand.
The calculated frequency is needed temporarily only.
Note that this is a migration compatibility break for all boards
types that use the EPIT peripheral.
Signed-off-by: Axel Heider <axel.heider@hensoldt.net> Reviewed-by: Peter Maydell <peter.maydell@linaro.org> Signed-off-by: Peter Maydell <peter.maydell@linaro.org>