]> git.ipfire.org Git - thirdparty/kernel/linux.git/commitdiff
regulator: core: Add error flags to sysfs attributes
authorZev Weiss <zev@bewilderbeest.net>
Wed, 4 May 2022 06:52:49 +0000 (23:52 -0700)
committerMark Brown <broonie@kernel.org>
Wed, 4 May 2022 14:31:26 +0000 (15:31 +0100)
If a regulator provides a get_error_flags() operation, its sysfs
attributes will now include an entry for each defined
REGULATOR_ERROR_* flag.

Signed-off-by: Zev Weiss <zev@bewilderbeest.net>
Link: https://lore.kernel.org/r/20220504065252.6955-3-zev@bewilderbeest.net
Signed-off-by: Mark Brown <broonie@kernel.org>
Documentation/ABI/testing/sysfs-class-regulator
drivers/regulator/core.c

index 8516f08806dd992b04841d48d4ec55410d9189fb..475b9a372657be033fe97d97c8117d0228988b6b 100644 (file)
@@ -370,3 +370,84 @@ Description:
 
                'unknown' means software cannot determine the state, or
                the reported state is invalid.
+
+What:          /sys/class/regulator/.../under_voltage
+Date:          April 2022
+KernelVersion: 5.18
+Contact:       Zev Weiss <zev@bewilderbeest.net>
+Description:
+               Some regulator directories will contain a field called
+               under_voltage.  This indicates if the device reports an
+               under-voltage fault (1) or not (0).
+
+What:          /sys/class/regulator/.../over_current
+Date:          April 2022
+KernelVersion: 5.18
+Contact:       Zev Weiss <zev@bewilderbeest.net>
+Description:
+               Some regulator directories will contain a field called
+               over_current.  This indicates if the device reports an
+               over-current fault (1) or not (0).
+
+What:          /sys/class/regulator/.../regulation_out
+Date:          April 2022
+KernelVersion: 5.18
+Contact:       Zev Weiss <zev@bewilderbeest.net>
+Description:
+               Some regulator directories will contain a field called
+               regulation_out.  This indicates if the device reports an
+               out-of-regulation fault (1) or not (0).
+
+What:          /sys/class/regulator/.../fail
+Date:          April 2022
+KernelVersion: 5.18
+Contact:       Zev Weiss <zev@bewilderbeest.net>
+Description:
+               Some regulator directories will contain a field called
+               fail.  This indicates if the device reports an output failure
+               (1) or not (0).
+
+What:          /sys/class/regulator/.../over_temp
+Date:          April 2022
+KernelVersion: 5.18
+Contact:       Zev Weiss <zev@bewilderbeest.net>
+Description:
+               Some regulator directories will contain a field called
+               over_temp.  This indicates if the device reports an
+               over-temperature fault (1) or not (0).
+
+What:          /sys/class/regulator/.../under_voltage_warn
+Date:          April 2022
+KernelVersion: 5.18
+Contact:       Zev Weiss <zev@bewilderbeest.net>
+Description:
+               Some regulator directories will contain a field called
+               under_voltage_warn.  This indicates if the device reports an
+               under-voltage warning (1) or not (0).
+
+What:          /sys/class/regulator/.../over_current_warn
+Date:          April 2022
+KernelVersion: 5.18
+Contact:       Zev Weiss <zev@bewilderbeest.net>
+Description:
+               Some regulator directories will contain a field called
+               over_current_warn.  This indicates if the device reports an
+               over-current warning (1) or not (0).
+
+What:          /sys/class/regulator/.../over_voltage_warn
+Date:          April 2022
+KernelVersion: 5.18
+Contact:       Zev Weiss <zev@bewilderbeest.net>
+Description:
+               Some regulator directories will contain a field called
+               over_voltage_warn.  This indicates if the device reports an
+               over-voltage warning (1) or not (0).
+
+What:          /sys/class/regulator/.../over_temp_warn
+Date:          April 2022
+KernelVersion: 5.18
+Contact:       Zev Weiss <zev@bewilderbeest.net>
+Description:
+               Some regulator directories will contain a field called
+               over_temp_warn.  This indicates if the device reports an
+               over-temperature warning (1) or not (0).
index ce3786e966c3a0131feb5985a1bd892bb7bef139..d790f7b648b1e6e601260b3cb066ebfe4bc048fa 100644 (file)
@@ -83,6 +83,7 @@ struct regulator_supply_alias {
 
 static int _regulator_is_enabled(struct regulator_dev *rdev);
 static int _regulator_disable(struct regulator *regulator);
+static int _regulator_get_error_flags(struct regulator_dev *rdev, unsigned int *flags);
 static int _regulator_get_current_limit(struct regulator_dev *rdev);
 static unsigned int _regulator_get_mode(struct regulator_dev *rdev);
 static int _notifier_call_chain(struct regulator_dev *rdev,
@@ -911,6 +912,30 @@ static ssize_t bypass_show(struct device *dev,
 }
 static DEVICE_ATTR_RO(bypass);
 
+#define REGULATOR_ERROR_ATTR(name, bit)                                                        \
+       static ssize_t name##_show(struct device *dev, struct device_attribute *attr,   \
+                                  char *buf)                                           \
+       {                                                                               \
+               int ret;                                                                \
+               unsigned int flags;                                                     \
+               struct regulator_dev *rdev = dev_get_drvdata(dev);                      \
+               ret = _regulator_get_error_flags(rdev, &flags);                         \
+               if (ret)                                                                \
+                       return ret;                                                     \
+               return sysfs_emit(buf, "%d\n", !!(flags & (bit)));                      \
+       }                                                                               \
+       static DEVICE_ATTR_RO(name)
+
+REGULATOR_ERROR_ATTR(under_voltage, REGULATOR_ERROR_UNDER_VOLTAGE);
+REGULATOR_ERROR_ATTR(over_current, REGULATOR_ERROR_OVER_CURRENT);
+REGULATOR_ERROR_ATTR(regulation_out, REGULATOR_ERROR_REGULATION_OUT);
+REGULATOR_ERROR_ATTR(fail, REGULATOR_ERROR_FAIL);
+REGULATOR_ERROR_ATTR(over_temp, REGULATOR_ERROR_OVER_TEMP);
+REGULATOR_ERROR_ATTR(under_voltage_warn, REGULATOR_ERROR_UNDER_VOLTAGE_WARN);
+REGULATOR_ERROR_ATTR(over_current_warn, REGULATOR_ERROR_OVER_CURRENT_WARN);
+REGULATOR_ERROR_ATTR(over_voltage_warn, REGULATOR_ERROR_OVER_VOLTAGE_WARN);
+REGULATOR_ERROR_ATTR(over_temp_warn, REGULATOR_ERROR_OVER_TEMP_WARN);
+
 /* Calculate the new optimum regulator operating mode based on the new total
  * consumer load. All locks held by caller
  */
@@ -4984,6 +5009,15 @@ static struct attribute *regulator_dev_attrs[] = {
        &dev_attr_max_microvolts.attr,
        &dev_attr_min_microamps.attr,
        &dev_attr_max_microamps.attr,
+       &dev_attr_under_voltage.attr,
+       &dev_attr_over_current.attr,
+       &dev_attr_regulation_out.attr,
+       &dev_attr_fail.attr,
+       &dev_attr_over_temp.attr,
+       &dev_attr_under_voltage_warn.attr,
+       &dev_attr_over_current_warn.attr,
+       &dev_attr_over_voltage_warn.attr,
+       &dev_attr_over_temp_warn.attr,
        &dev_attr_suspend_standby_state.attr,
        &dev_attr_suspend_mem_state.attr,
        &dev_attr_suspend_disk_state.attr,
@@ -5039,6 +5073,17 @@ static umode_t regulator_attr_is_visible(struct kobject *kobj,
        if (attr == &dev_attr_bypass.attr)
                return ops->get_bypass ? mode : 0;
 
+       if (attr == &dev_attr_under_voltage.attr ||
+           attr == &dev_attr_over_current.attr ||
+           attr == &dev_attr_regulation_out.attr ||
+           attr == &dev_attr_fail.attr ||
+           attr == &dev_attr_over_temp.attr ||
+           attr == &dev_attr_under_voltage_warn.attr ||
+           attr == &dev_attr_over_current_warn.attr ||
+           attr == &dev_attr_over_voltage_warn.attr ||
+           attr == &dev_attr_over_temp_warn.attr)
+               return ops->get_error_flags ? mode : 0;
+
        /* constraints need specific supporting methods */
        if (attr == &dev_attr_min_microvolts.attr ||