Add new result codes to support TDR diagnostics in preparation for
Open Alliance 1000BaseT1 TDR support:
- ETHTOOL_A_CABLE_RESULT_CODE_NOISE: TDR not possible due to high noise
level.
- ETHTOOL_A_CABLE_RESULT_CODE_RESOLUTION_NOT_POSSIBLE: TDR resolution not
possible / out of distance.
Reviewed-by: Andrew Lunn <andrew@lunn.ch>
Signed-off-by: Oleksij Rempel <o.rempel@pengutronix.de>
Link: https://patch.msgid.link/20240812073046.1728288-1-o.rempel@pengutronix.de
Signed-off-by: Jakub Kicinski <kuba@kernel.org>
* a regular 100 Ohm cable and a part with the abnormal impedance value
*/
ETHTOOL_A_CABLE_RESULT_CODE_IMPEDANCE_MISMATCH,
+ /* TDR not possible due to high noise level */
+ ETHTOOL_A_CABLE_RESULT_CODE_NOISE,
+ /* TDR resolution not possible / out of distance */
+ ETHTOOL_A_CABLE_RESULT_CODE_RESOLUTION_NOT_POSSIBLE,
};
enum {