queue-4.14/iio-accel-bma180-fix-bma25x-bandwidth-register-values.patch
queue-4.19/iio-accel-bma180-fix-bma25x-bandwidth-register-values.patch
queue-4.4/iio-accel-bma180-fix-bma25x-bandwidth-register-values.patch
queue-4.9/iio-accel-bma180-fix-bma25x-bandwidth-register-values.patch
queue-5.4/iio-accel-bma180-fix-bma25x-bandwidth-register-values.patch

index 23f60ba85dd07fa88b2304811168184aa9a8be31..c97494d931045da4e5c8ce686f1b366d876dd03f 100644 (file)
@@ -11,7 +11,7 @@ According to the BMA253 datasheet [1] and BMA250 datasheet [2] the
 bandwidth value for BMA25x should be set as 01xxx:
 
   "Settings 00xxx result in a bandwidth of 7.81 Hz; [...]
-   It is recommended [...] to use the range from ´01000b´ to ´01111b´
+   It is recommended [...] to use the range from Â´01000b´ to Â´01111b´
    only in order to be compatible with future products."
 
 However, at the moment the drivers sets bandwidth values from 0 to 6,
index 3ca5bb525aeb21575024136405d100d8ab1d26ec..db2da9ca56a2e4216ea1f03b8927102ed01105e8 100644 (file)
@@ -11,7 +11,7 @@ According to the BMA253 datasheet [1] and BMA250 datasheet [2] the
 bandwidth value for BMA25x should be set as 01xxx:
 
   "Settings 00xxx result in a bandwidth of 7.81 Hz; [...]
-   It is recommended [...] to use the range from ´01000b´ to ´01111b´
+   It is recommended [...] to use the range from Â´01000b´ to Â´01111b´
    only in order to be compatible with future products."
 
 However, at the moment the drivers sets bandwidth values from 0 to 6,
index 48d939c2693a47845307aa00f9e9f3c6b6c62c49..48f597f68f9a5b91cc6d37c375430354b3395f7f 100644 (file)
@@ -11,7 +11,7 @@ According to the BMA253 datasheet [1] and BMA250 datasheet [2] the
 bandwidth value for BMA25x should be set as 01xxx:
 
   "Settings 00xxx result in a bandwidth of 7.81 Hz; [...]
-   It is recommended [...] to use the range from ´01000b´ to ´01111b´
+   It is recommended [...] to use the range from Â´01000b´ to Â´01111b´
    only in order to be compatible with future products."
 
 However, at the moment the drivers sets bandwidth values from 0 to 6,
index a0bffd42c2a22cd59b49c400d5f27f891e148850..3d1d940996d5285d4dbdc516ea26f31fefdd31c4 100644 (file)
@@ -11,7 +11,7 @@ According to the BMA253 datasheet [1] and BMA250 datasheet [2] the
 bandwidth value for BMA25x should be set as 01xxx:
 
   "Settings 00xxx result in a bandwidth of 7.81 Hz; [...]
-   It is recommended [...] to use the range from ´01000b´ to ´01111b´
+   It is recommended [...] to use the range from Â´01000b´ to Â´01111b´
    only in order to be compatible with future products."
 
 However, at the moment the drivers sets bandwidth values from 0 to 6,
index 363088bc25a7e583712ca1876a1477d1128a79c8..cf0887b2119892b4d8ceb41d4526c0181d47b543 100644 (file)
@@ -11,7 +11,7 @@ According to the BMA253 datasheet [1] and BMA250 datasheet [2] the
 bandwidth value for BMA25x should be set as 01xxx:
 
   "Settings 00xxx result in a bandwidth of 7.81 Hz; [...]
-   It is recommended [...] to use the range from ´01000b´ to ´01111b´
+   It is recommended [...] to use the range from Â´01000b´ to Â´01111b´
    only in order to be compatible with future products."
 
 However, at the moment the drivers sets bandwidth values from 0 to 6,