The initial version of the RAA228228 datasheet claimed that the device
supported READ_TEMPERATURE_3 but not READ_TEMPERATURE_1. It has since been
discovered that the datasheet was incorrect. The RAA228228 does support
READ_TEMPERATURE_1 but does not support READ_TEMPERATURE_3.
Signed-off-by: Grant Peltier <grantpeltier93@gmail.com>
Fixes: 51fb91ed5a6f ("hwmon: (pmbus/isl68137) remove READ_TEMPERATURE_1 telemetry for RAA228228")
Link: https://lore.kernel.org/r/20210514211954.GA24646@raspberrypi
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
info->read_word_data = raa_dmpvr2_read_word_data;
break;
case raa_dmpvr2_2rail_nontc:
- info->func[0] &= ~PMBUS_HAVE_TEMP;
- info->func[1] &= ~PMBUS_HAVE_TEMP;
+ info->func[0] &= ~PMBUS_HAVE_TEMP3;
+ info->func[1] &= ~PMBUS_HAVE_TEMP3;
fallthrough;
case raa_dmpvr2_2rail:
info->pages = 2;