In SPI mode, the ACMD41 argument only defines bit 30 (HCS); all other
bits are reserved. The current implementation incorrectly checks the
voltage window bits even in SPI mode, preventing the state machine
from transitioning to the READY state. As a result, the U-Boot
mmc-spi driver falls into an endless CMD55/ACMD41 loop.
Fixes: 3241a61a ("hw/sd/sdcard: Use complete SEND_OP_COND implementation in SPI mode")
Resolves: https://gitlab.com/qemu-project/qemu/-/issues/2945
Reported-by: Tom Rini <trini@konsulko.com>
Signed-off-by: Bin Meng <bmeng.cn@gmail.com>
Reviewed-by: Philippe Mathieu-Daudé <philmd@linaro.org>
Message-ID: <
20251110110507.
1641042-3-bmeng.cn@gmail.com>
Signed-off-by: Philippe Mathieu-Daudé <philmd@linaro.org>
}
}
- if (FIELD_EX32(sd->ocr & req.arg, OCR, VDD_VOLTAGE_WINDOW)) {
- /*
- * We accept any voltage. 10000 V is nothing.
- *
- * Once we're powered up, we advance straight to ready state
- * unless it's an enquiry ACMD41 (bits 23:0 == 0).
- */
- sd->state = sd_ready_state;
- }
-
if (sd_is_spi(sd)) {
+ sd->state = sd_ready_state;
return sd_r1;
+ } else {
+ if (FIELD_EX32(sd->ocr & req.arg, OCR, VDD_VOLTAGE_WINDOW)) {
+ /*
+ * We accept any voltage. 10000 V is nothing.
+ *
+ * Once we're powered up, we advance straight to ready state
+ * unless it's an enquiry ACMD41 (bits 23:0 == 0).
+ */
+ sd->state = sd_ready_state;
+ }
+ return sd_r3;
}
- return sd_r3;
}
/* ACMD42 */