link_hwss->disable_link_output(link, link_res, signal);
link->phy_state.symclk_state = SYMCLK_OFF_TX_OFF;
-
- if (signal == SIGNAL_TYPE_EDP &&
- link->dc->hwss.edp_power_control &&
- !link->skip_implict_edp_power_control)
- link->dc->hwss.edp_power_control(link, false);
- else if (dmcu != NULL && dmcu->funcs->unlock_phy)
+ /*
+ * Add the logic to extract BOTH power up and power down sequences
+ * from enable/disable link output and only call edp panel control
+ * in enable_link_dp and disable_link_dp once.
+ */
+ if (dmcu != NULL && dmcu->funcs->unlock_phy)
dmcu->funcs->unlock_phy(dmcu);
dc->link_srv->dp_trace_source_sequence(link, DPCD_SOURCE_SEQ_AFTER_DISABLE_LINK_PHY);