val = readl(data->regs + BCM2835_TS_TSENSCTL);
if (!(val & BCM2835_TS_TSENSCTL_RSTB)) {
- struct thermal_trip trip;
- int offset, slope;
+ int offset, slope, crit_temp;
slope = thermal_zone_get_slope(tz);
offset = thermal_zone_get_offset(tz);
* For now we deal only with critical, otherwise
* would need to iterate
*/
- err = thermal_zone_get_trip(tz, 0, &trip);
+ err = thermal_zone_get_crit_temp(tz, &crit_temp);
if (err < 0) {
dev_err(dev, "Not able to read trip_temp: %d\n", err);
return err;
val |= (0xFE << BCM2835_TS_TSENSCTL_RSTDELAY_SHIFT);
/* trip_adc value from info */
- val |= bcm2835_thermal_temp2adc(trip.temperature,
+ val |= bcm2835_thermal_temp2adc(crit_temp,
offset,
slope)
<< BCM2835_TS_TSENSCTL_THOLD_SHIFT;