Sending an PF_PACKET allows to bypass the CAN framework logic and to
directly reach the xmit() function of a CAN driver. The only check
which is performed by the PF_PACKET framework is to make sure that
skb->len fits the interface's MTU.
Unfortunately, because the sun4i_can driver does not populate its
net_device_ops->ndo_change_mtu(), it is possible for an attacker to
configure an invalid MTU by doing, for example:
$ ip link set can0 mtu 9999
After doing so, the attacker could open a PF_PACKET socket using the
ETH_P_CANXL protocol:
socket(PF_PACKET, SOCK_RAW, htons(ETH_P_CANXL))
to inject a malicious CAN XL frames. For example:
struct canxl_frame frame = {
.flags = 0xff,
.len = 2048,
};
The CAN drivers' xmit() function are calling can_dev_dropped_skb() to
check that the skb is valid, unfortunately under above conditions, the
malicious packet is able to go through can_dev_dropped_skb() checks:
1. the skb->protocol is set to ETH_P_CANXL which is valid (the
function does not check the actual device capabilities).
2. the length is a valid CAN XL length.
And so, hi3110_hard_start_xmit() receives a CAN XL frame which it is
not able to correctly handle and will thus misinterpret it as a CAN
frame. The driver will consume frame->len as-is with no further
checks.
This can result in a buffer overflow later on in hi3110_hw_tx() on
this line:
memcpy(buf + HI3110_FIFO_EXT_DATA_OFF,
frame->data, frame->len);
Here, frame->len corresponds to the flags field of the CAN XL frame.
In our previous example, we set canxl_frame->flags to 0xff. Because
the maximum expected length is 8, a buffer overflow of 247 bytes
occurs!
Populate net_device_ops->ndo_change_mtu() to ensure that the
interface's MTU can not be set to anything bigger than CAN_MTU. By
fixing the root cause, this prevents the buffer overflow.
Fixes: 57e83fb9b746 ("can: hi311x: Add Holt HI-311x CAN driver")
Signed-off-by: Vincent Mailhol <mailhol@kernel.org>
Link: https://patch.msgid.link/20250918-can-fix-mtu-v1-2-0d1cada9393b@kernel.org
Signed-off-by: Marc Kleine-Budde <mkl@pengutronix.de>