When user sets SIGBUS to SIG_IGN, it won't cause loop now. For action
required mce error, SIGBUS cannot be blocked. Also when a hwpoisoned page
is re-accessed, kill_accessing_process() will be called to kill the
process.
Link: https://lkml.kernel.org/r/20240612071835.157004-13-linmiaohe@huawei.com
Signed-off-by: Miaohe Lin <linmiaohe@huawei.com>
Cc: Borislav Petkov (AMD) <bp@alien8.de>
Cc: David Hildenbrand <david@redhat.com>
Cc: kernel test robot <lkp@intel.com>
Cc: Naoya Horiguchi <nao.horiguchi@gmail.com>
Cc: Tony Luck <tony.luck@intel.com>
Signed-off-by: Andrew Morton <akpm@linux-foundation.org>
* PF_MCE_EARLY set.
* Don't use force here, it's convenient if the signal
* can be temporarily blocked.
- * This could cause a loop when the user sets SIGBUS
- * to SIG_IGN, but hopefully no one will do that?
*/
ret = send_sig_mceerr(BUS_MCEERR_AO, (void __user *)tk->addr,
addr_lsb, t);