1 .TH MD 4
2 .SH NAME
3 md \- Multiple Device driver aka Linux Software Raid
4 .SH SYNOPSIS
5 .BI /dev/md n
6 .br
7 .BI /dev/md/ n
8 .SH DESCRIPTION
9 The
10 .B md
11 driver provides virtual devices that are created from one or more
12 independent underlying devices. This array of devices often contains
13 redundancy, and hence the acronym RAID which stands for a Redundant
14 Array of Independent Devices.
15 .PP
16 .B md
17 supports RAID levels 1 (mirroring) 4 (striped array with parity
18 device) and 5 (striped array with distributed parity information).
19 If a single underlying device fails while using one of these levels,
20 the array will continue to function.
21 .PP
22 .B md
23 also supports a number of pseudo RAID (non-redundant) configurations
24 including RAID0 (striped array), LINEAR (catenated array) and
25 MULTIPATH (a set of different interfaces to the same device).
26
27 .SS MD SUPER BLOCK
28 With the exception of Legacy Arrays described below, each device that
29 is incorporated into an MD array has a
30 .I super block
31 written towards the end of the device. This superblock records
32 information about the structure and state of the array so that the
33 array can be reliably re-assembled after a shutdown.
34
35 The superblock is 4K long and is written into a 64K aligned block that
36 starts at least 64K and less than 128K from the end of the device
37 (i.e. to get the address of the superblock round the size of the
38 device down to a multiple of 64K and then subtract 64K).
39 The available size of each device is the amount of space before the
40 super block, so between 64K and 128K is lost when a device in
41 incorporated into an MD array.
42
43 The superblock contains, among other things:
44 .TP
45 LEVEL
46 The manner in which the devices are arranged into the array
47 (linear, raid0, raid1, raid4, raid5, multipath).
48 .TP
49 UUID
50 a 128 bit Universally Unique Identifier that identifies the array that
51 this device is part of.
52
53 .SS LEGACY ARRAYS
54 Early versions of the
55 .B md
56 driver only supported Linear and Raid0 configurations and so
57 did not use an MD superblock (as there is no state that needs to be
58 recorded). While it is strongly recommended that all newly created
59 arrays utilise a superblock to help ensure that they are assembled
60 properly, the
61 .B md
62 driver still supports legacy linear and raid0 md arrays that
63 do not have a superblock.
64
65 .SS LINEAR
66
67 A linear array simply catenates the available space on each
68 drive together to form one large virtual drive.
69
70 One advantage of this arrangement over the more common RAID0
71 arrangement is that the array may be reconfigured at a later time with
72 an extra drive and so the array is made bigger without disturbing the
73 data that is on the array. However this cannot be done on a live
74 array.
75
76
77 .SS RAID0
78
79 A RAID0 array (which has zero redundancy) is also known as a
80 striped array.
81 A RAID0 array is configured at creation with a
82 .B "Chunk Size"
83 which must be a power of two, and at least 4 kibibytes.
84
85 The RAID0 driver assigns the first chunk of the array to the first
86 device, the second chunk to the second device, and so on until all
87 drives have been assigned one chunk. This collection of chunks forms
88 a
89 .BR stripe .
90 Further chunks are gathered into stripes in the same way which are
91 assigned to the remaining space in the drives.
92
93 If devices in the array are not all the same size, then once the
94 smallest device has been exhausted, the RAID0 driver starts
95 collecting chunks into smaller stripes that only span the drives which
96 still have remaining space.
97
98
99 .SS RAID1
100
101 A RAID1 array is also known as a mirrored set (though mirrors tend to
102 provide reflected images, which RAID1 does not) or a plex.
103
104 Once initialised, each device in a RAID1 array contains exactly the
105 same data. Changes are written to all devices in parallel. Data is
106 read from any one device. The driver attempts to distribute read
107 requests across all devices to maximise performance.
108
109 All devices in a RAID1 array should be the same size. If they are
110 not, then only the amount of space available on the smallest device is
111 used. Any extra space on other devices is wasted.
112
113 .SS RAID4
114
115 A RAID4 array is like a RAID0 array with an extra device for storing
116 parity. This device is the last of the active devices in the
117 array. Unlike RAID0, RAID4 also requires that all stripes span all
118 drives, so extra space on devices that are larger than the smallest is
119 wasted.
120
121 When any block in a RAID4 array is modified the parity block for that
122 stripe (i.e. the block in the parity device at the same device offset
123 as the stripe) is also modified so that the parity block always
124 contains the "parity" for the whole stripe. i.e. its contents is
125 equivalent to the result of performing an exclusive-or operation
126 between all the data blocks in the stripe.
127
128 This allows the array to continue to function if one device fails.
129 The data that was on that device can be calculated as needed from the
130 parity block and the other data blocks.
131
132 .SS RAID5
133
134 RAID5 is very similar to RAID4. The difference is that the parity
135 blocks for each stripe, instead of being on a single device, are
136 distributed across all devices. This allows more parallelism when
137 writing as two different block updates will quite possibly affect
138 parity blocks on different devices so there is less contention.
139
140 This also allows more parallelism when reading as read requests are
141 distributed over all the devices in the array instead of all but one.
142
143 .SS MUTIPATH
144
145 MULTIPATH is not really a RAID at all as there is only one real device
146 in a MULTIPATH md array. However there are multiple access points
147 (paths) to this device, and one of these paths might fail, so there
148 are some similarities.
149
150 A MULTIPATH array is composed of a number of logical different
151 devices, often fibre channel interfaces, that all refer the the same
152 real device. If one of these interfaces fails (e.g. due to cable
153 problems), the multipath driver to attempt to redirect requests to
154 another interface.
155
156
157 .SS UNCLEAN SHUTDOWN
158
159 When changes are made to a RAID1, RAID4, or RAID5 array there is a
160 possibility of inconsistency for short periods of time as each update
161 requires are least two block to be written to different devices, and
162 these writes probably wont happen at exactly the same time.
163 Thus if a system with one of these arrays is shutdown in the middle of
164 a write operation (e.g. due to power failure), the array may not be
165 consistent.
166
167 To handle this situation, the md driver marks an array as "dirty"
168 before writing any data to it, and marks it as "clean" when the array
169 is being disabled, e.g. at shutdown.
170 If the md driver finds an array to be dirty at startup, it proceeds to
171 correct any possibly inconsistency. For RAID1, this involves copying
172 the contents of the first drive onto all other drives.
173 For RAID4 or RAID5 this involves recalculating the parity for each
174 stripe and making sure that the parity block has the correct data.
175 This process, known as "resynchronising" or "resync" is performed in
176 the background. The array can still be used, though possibly with
177 reduced performance.
178
179 If a RAID4 or RAID5 array is degraded (missing one drive) when it is
180 restarted after an unclean shutdown, it cannot recalculate parity, and
181 so it is possible that data might be undetectably corrupted.
182 The 2.4 md driver
183 .B does not
184 alert the operator to this condition. The 2.5 md driver will fail to
185 start an array in this condition without manual intervention.
186
187 .SS RECOVERY
188
189 If the md driver detects any error on a device in a RAID1, RAID4, or
190 RAID5 array, it immediately disables that device (marking it as faulty)
191 and continues operation on the remaining devices. If there is a spare
192 drive, the driver will start recreating on one of the spare drives the
193 data what was on that failed drive, either by copying a working drive
194 in a RAID1 configuration, or by doing calculations with the parity
195 block on RAID4 and RAID5.
196
197 While this recovery process is happening, the md driver will monitor
198 accesses to the array and will slow down the rate of recovery if other
199 activity is happening, so that normal access to the array will not be
200 unduly affected. When no other activity is happening, the recovery
201 process proceeds at full speed. The actual speed targets for the two
202 different situations can be controlled by the
203 .B speed_limit_min
204 and
205 .B speed_limit_max
206 control files mentioned below.
207
208 .SS KERNEL PARAMETERS
209
210 The md driver recognised three different kernel parameters.
211 .TP
212 .B raid=noautodetect
213 This will disable the normal detection of md arrays that happens at
214 boot time. If a drive is partitioned with MS-DOS style partitions,
215 then if any of the 4 main partitions has a partition type of 0xFD,
216 then that partition will normally be inspected to see if it is part of
217 an MD array, and if any full arrays are found, they are started. This
218 kernel paramenter disables this behaviour.
219
220 .TP
221 .BI md= n , dev , dev ,...
222 This tells the md driver to assemble
223 .B /dev/md n
224 from the listed devices. It is only necessary to start the device
225 holding the root filesystem this way. Other arrays are best started
226 once the system is booted.
227
228 .TP
229 .BI md= n , l , c , i , dev...
230 This tells the md driver to assemble a legacy RAID0 or LINEAR array
231 without a superblock.
232 .I n
233 gives the md device number,
234 .I l
235 gives the level, 0 for RAID0 or -1 for LINEAR,
236 .I c
237 gives the chunk size as a base-2 logarithm offset by twelve, so 0
238 means 4K, 1 means 8K.
239 .I i
240 is ignored (legacy support).
241
242 .SH FILES
243 .TP
244 .B /proc/mdstat
245 Contains information about the status of currently running array.
246 .TP
247 .B /proc/sys/dev/raid/speed_limit_min
248 A readable and writable file that reflects the current goal rebuild
249 speed for times when non-rebuild activity is current on an array.
250 The speed is in Kibibytes per second, and is a per-device rate, not a
251 per-array rate (which means that an array with more disc will shuffle
252 more data for a given speed). The default is 100.
253
254 .TP
255 .B /proc/sys/dev/raid/speed_limit_max
256 A readable and writable file that reflects the current goal rebuild
257 speed for times when no non-rebuild activity is current on an array.
258 The default is 100,000.
259
260 .SH SEE ALSO
261 .BR mdadm (8),
262 .BR mkraid (8).