]> git.ipfire.org Git - thirdparty/mdadm.git/blob - md.4
mdadm-1.5.0
[thirdparty/mdadm.git] / md.4
1 .TH MD 4
2 .SH NAME
3 md \- Multiple Device driver aka Linux Software Raid
4 .SH SYNOPSIS
5 .BI /dev/md n
6 .br
7 .BI /dev/md/ n
8 .SH DESCRIPTION
9 The
10 .B md
11 driver provides virtual devices that are created from one or more
12 independent underlying devices. This array of devices often contains
13 redundancy, and hence the acronym RAID which stands for a Redundant
14 Array of Independent Devices.
15 .PP
16 .B md
17 supports RAID levels 1 (mirroring) 4 (striped array with parity
18 device), 5 (striped array with distributed parity information) and 6
19 (striped array with distributed dual redundancy information.) If a
20 some number of underlying devices fails while using one of these
21 levels, the array will continue to function; this number is one for
22 RAID levels 4 and 5, two for RAID level 6, and all but one (N-1) for
23 RAID level 1.
24 .PP
25 .B md
26 also supports a number of pseudo RAID (non-redundant) configurations
27 including RAID0 (striped array), LINEAR (catenated array) and
28 MULTIPATH (a set of different interfaces to the same device).
29
30 .SS MD SUPER BLOCK
31 With the exception of Legacy Arrays described below, each device that
32 is incorporated into an MD array has a
33 .I super block
34 written towards the end of the device. This superblock records
35 information about the structure and state of the array so that the
36 array can be reliably re-assembled after a shutdown.
37
38 The superblock is 4K long and is written into a 64K aligned block that
39 starts at least 64K and less than 128K from the end of the device
40 (i.e. to get the address of the superblock round the size of the
41 device down to a multiple of 64K and then subtract 64K).
42 The available size of each device is the amount of space before the
43 super block, so between 64K and 128K is lost when a device in
44 incorporated into an MD array.
45
46 The superblock contains, among other things:
47 .TP
48 LEVEL
49 The manner in which the devices are arranged into the array
50 (linear, raid0, raid1, raid4, raid5, multipath).
51 .TP
52 UUID
53 a 128 bit Universally Unique Identifier that identifies the array that
54 this device is part of.
55
56 .SS LEGACY ARRAYS
57 Early versions of the
58 .B md
59 driver only supported Linear and Raid0 configurations and so
60 did not use an MD superblock (as there is no state that needs to be
61 recorded). While it is strongly recommended that all newly created
62 arrays utilise a superblock to help ensure that they are assembled
63 properly, the
64 .B md
65 driver still supports legacy linear and raid0 md arrays that
66 do not have a superblock.
67
68 .SS LINEAR
69
70 A linear array simply catenates the available space on each
71 drive together to form one large virtual drive.
72
73 One advantage of this arrangement over the more common RAID0
74 arrangement is that the array may be reconfigured at a later time with
75 an extra drive and so the array is made bigger without disturbing the
76 data that is on the array. However this cannot be done on a live
77 array.
78
79
80 .SS RAID0
81
82 A RAID0 array (which has zero redundancy) is also known as a
83 striped array.
84 A RAID0 array is configured at creation with a
85 .B "Chunk Size"
86 which must be a power of two, and at least 4 kibibytes.
87
88 The RAID0 driver assigns the first chunk of the array to the first
89 device, the second chunk to the second device, and so on until all
90 drives have been assigned one chunk. This collection of chunks forms
91 a
92 .BR stripe .
93 Further chunks are gathered into stripes in the same way which are
94 assigned to the remaining space in the drives.
95
96 If devices in the array are not all the same size, then once the
97 smallest device has been exhausted, the RAID0 driver starts
98 collecting chunks into smaller stripes that only span the drives which
99 still have remaining space.
100
101
102 .SS RAID1
103
104 A RAID1 array is also known as a mirrored set (though mirrors tend to
105 provide reflected images, which RAID1 does not) or a plex.
106
107 Once initialised, each device in a RAID1 array contains exactly the
108 same data. Changes are written to all devices in parallel. Data is
109 read from any one device. The driver attempts to distribute read
110 requests across all devices to maximise performance.
111
112 All devices in a RAID1 array should be the same size. If they are
113 not, then only the amount of space available on the smallest device is
114 used. Any extra space on other devices is wasted.
115
116 .SS RAID4
117
118 A RAID4 array is like a RAID0 array with an extra device for storing
119 parity. This device is the last of the active devices in the
120 array. Unlike RAID0, RAID4 also requires that all stripes span all
121 drives, so extra space on devices that are larger than the smallest is
122 wasted.
123
124 When any block in a RAID4 array is modified the parity block for that
125 stripe (i.e. the block in the parity device at the same device offset
126 as the stripe) is also modified so that the parity block always
127 contains the "parity" for the whole stripe. i.e. its contents is
128 equivalent to the result of performing an exclusive-or operation
129 between all the data blocks in the stripe.
130
131 This allows the array to continue to function if one device fails.
132 The data that was on that device can be calculated as needed from the
133 parity block and the other data blocks.
134
135 .SS RAID5
136
137 RAID5 is very similar to RAID4. The difference is that the parity
138 blocks for each stripe, instead of being on a single device, are
139 distributed across all devices. This allows more parallelism when
140 writing as two different block updates will quite possibly affect
141 parity blocks on different devices so there is less contention.
142
143 This also allows more parallelism when reading as read requests are
144 distributed over all the devices in the array instead of all but one.
145
146 .SS RAID6
147
148 RAID6 is similar to RAID5, but can handle the loss of any \fItwo\fP
149 devices without data loss. Accordingly, it requires N+2 drives to
150 store N drives worth of data.
151
152 The performance for RAID6 is slightly lower but comparable to RAID5 in
153 normal mode and single disk failure mode. It is very slow in dual
154 disk failure mode, however.
155
156 .SS MUTIPATH
157
158 MULTIPATH is not really a RAID at all as there is only one real device
159 in a MULTIPATH md array. However there are multiple access points
160 (paths) to this device, and one of these paths might fail, so there
161 are some similarities.
162
163 A MULTIPATH array is composed of a number of logical different
164 devices, often fibre channel interfaces, that all refer the the same
165 real device. If one of these interfaces fails (e.g. due to cable
166 problems), the multipath driver to attempt to redirect requests to
167 another interface.
168
169
170 .SS UNCLEAN SHUTDOWN
171
172 When changes are made to a RAID1, RAID4, RAID5 or RAID6 array there is a
173 possibility of inconsistency for short periods of time as each update
174 requires are least two block to be written to different devices, and
175 these writes probably wont happen at exactly the same time.
176 Thus if a system with one of these arrays is shutdown in the middle of
177 a write operation (e.g. due to power failure), the array may not be
178 consistent.
179
180 To handle this situation, the md driver marks an array as "dirty"
181 before writing any data to it, and marks it as "clean" when the array
182 is being disabled, e.g. at shutdown. If the md driver finds an array
183 to be dirty at startup, it proceeds to correct any possibly
184 inconsistency. For RAID1, this involves copying the contents of the
185 first drive onto all other drives. For RAID4, RAID5 and RAID6 this
186 involves recalculating the parity for each stripe and making sure that
187 the parity block has the correct data. This process, known as
188 "resynchronising" or "resync" is performed in the background. The
189 array can still be used, though possibly with reduced performance.
190
191 If a RAID4, RAID5 or RAID6 array is degraded (missing at least one
192 drive) when it is restarted after an unclean shutdown, it cannot
193 recalculate parity, and so it is possible that data might be
194 undetectably corrupted. The 2.4 md driver
195 .B does not
196 alert the operator to this condition. The 2.5 md driver will fail to
197 start an array in this condition without manual intervention.
198
199 .SS RECOVERY
200
201 If the md driver detects any error on a device in a RAID1, RAID4,
202 RAID5 or RAID6 array, it immediately disables that device (marking it
203 as faulty) and continues operation on the remaining devices. If there
204 is a spare drive, the driver will start recreating on one of the spare
205 drives the data what was on that failed drive, either by copying a
206 working drive in a RAID1 configuration, or by doing calculations with
207 the parity block on RAID4, RAID5 or RAID6.
208
209 While this recovery process is happening, the md driver will monitor
210 accesses to the array and will slow down the rate of recovery if other
211 activity is happening, so that normal access to the array will not be
212 unduly affected. When no other activity is happening, the recovery
213 process proceeds at full speed. The actual speed targets for the two
214 different situations can be controlled by the
215 .B speed_limit_min
216 and
217 .B speed_limit_max
218 control files mentioned below.
219
220 .SS KERNEL PARAMETERS
221
222 The md driver recognised three different kernel parameters.
223 .TP
224 .B raid=noautodetect
225 This will disable the normal detection of md arrays that happens at
226 boot time. If a drive is partitioned with MS-DOS style partitions,
227 then if any of the 4 main partitions has a partition type of 0xFD,
228 then that partition will normally be inspected to see if it is part of
229 an MD array, and if any full arrays are found, they are started. This
230 kernel paramenter disables this behaviour.
231
232 .TP
233 .BI md= n , dev , dev ,...
234 This tells the md driver to assemble
235 .B /dev/md n
236 from the listed devices. It is only necessary to start the device
237 holding the root filesystem this way. Other arrays are best started
238 once the system is booted.
239
240 .TP
241 .BI md= n , l , c , i , dev...
242 This tells the md driver to assemble a legacy RAID0 or LINEAR array
243 without a superblock.
244 .I n
245 gives the md device number,
246 .I l
247 gives the level, 0 for RAID0 or -1 for LINEAR,
248 .I c
249 gives the chunk size as a base-2 logarithm offset by twelve, so 0
250 means 4K, 1 means 8K.
251 .I i
252 is ignored (legacy support).
253
254 .SH FILES
255 .TP
256 .B /proc/mdstat
257 Contains information about the status of currently running array.
258 .TP
259 .B /proc/sys/dev/raid/speed_limit_min
260 A readable and writable file that reflects the current goal rebuild
261 speed for times when non-rebuild activity is current on an array.
262 The speed is in Kibibytes per second, and is a per-device rate, not a
263 per-array rate (which means that an array with more disc will shuffle
264 more data for a given speed). The default is 100.
265
266 .TP
267 .B /proc/sys/dev/raid/speed_limit_max
268 A readable and writable file that reflects the current goal rebuild
269 speed for times when no non-rebuild activity is current on an array.
270 The default is 100,000.