]> git.ipfire.org Git - thirdparty/mdadm.git/blob - mdadm.8.in
Check all member devices in enough_fd
[thirdparty/mdadm.git] / mdadm.8.in
1 .\" -*- nroff -*-
2 .\" Copyright Neil Brown and others.
3 .\" This program is free software; you can redistribute it and/or modify
4 .\" it under the terms of the GNU General Public License as published by
5 .\" the Free Software Foundation; either version 2 of the License, or
6 .\" (at your option) any later version.
7 .\" See file COPYING in distribution for details.
8 .TH MDADM 8 "" v3.2.1
9 .SH NAME
10 mdadm \- manage MD devices
11 .I aka
12 Linux Software RAID
13
14 .SH SYNOPSIS
15
16 .BI mdadm " [mode] <raiddevice> [options] <component-devices>"
17
18 .SH DESCRIPTION
19 RAID devices are virtual devices created from two or more
20 real block devices. This allows multiple devices (typically disk
21 drives or partitions thereof) to be combined into a single device to
22 hold (for example) a single filesystem.
23 Some RAID levels include redundancy and so can survive some degree of
24 device failure.
25
26 Linux Software RAID devices are implemented through the md (Multiple
27 Devices) device driver.
28
29 Currently, Linux supports
30 .B LINEAR
31 md devices,
32 .B RAID0
33 (striping),
34 .B RAID1
35 (mirroring),
36 .BR RAID4 ,
37 .BR RAID5 ,
38 .BR RAID6 ,
39 .BR RAID10 ,
40 .BR MULTIPATH ,
41 .BR FAULTY ,
42 and
43 .BR CONTAINER .
44
45 .B MULTIPATH
46 is not a Software RAID mechanism, but does involve
47 multiple devices:
48 each device is a path to one common physical storage device.
49 New installations should not use md/multipath as it is not well
50 supported and has no ongoing development. Use the Device Mapper based
51 multipath-tools instead.
52
53 .B FAULTY
54 is also not true RAID, and it only involves one device. It
55 provides a layer over a true device that can be used to inject faults.
56
57 .B CONTAINER
58 is different again. A
59 .B CONTAINER
60 is a collection of devices that are
61 managed as a set. This is similar to the set of devices connected to
62 a hardware RAID controller. The set of devices may contain a number
63 of different RAID arrays each utilising some (or all) of the blocks from a
64 number of the devices in the set. For example, two devices in a 5-device set
65 might form a RAID1 using the whole devices. The remaining three might
66 have a RAID5 over the first half of each device, and a RAID0 over the
67 second half.
68
69 With a
70 .BR CONTAINER ,
71 there is one set of metadata that describes all of
72 the arrays in the container. So when
73 .I mdadm
74 creates a
75 .B CONTAINER
76 device, the device just represents the metadata. Other normal arrays (RAID1
77 etc) can be created inside the container.
78
79 .SH MODES
80 mdadm has several major modes of operation:
81 .TP
82 .B Assemble
83 Assemble the components of a previously created
84 array into an active array. Components can be explicitly given
85 or can be searched for.
86 .I mdadm
87 checks that the components
88 do form a bona fide array, and can, on request, fiddle superblock
89 information so as to assemble a faulty array.
90
91 .TP
92 .B Build
93 Build an array that doesn't have per-device metadata (superblocks). For these
94 sorts of arrays,
95 .I mdadm
96 cannot differentiate between initial creation and subsequent assembly
97 of an array. It also cannot perform any checks that appropriate
98 components have been requested. Because of this, the
99 .B Build
100 mode should only be used together with a complete understanding of
101 what you are doing.
102
103 .TP
104 .B Create
105 Create a new array with per-device metadata (superblocks).
106 Appropriate metadata is written to each device, and then the array
107 comprising those devices is activated. A 'resync' process is started
108 to make sure that the array is consistent (e.g. both sides of a mirror
109 contain the same data) but the content of the device is left otherwise
110 untouched.
111 The array can be used as soon as it has been created. There is no
112 need to wait for the initial resync to finish.
113
114 .TP
115 .B "Follow or Monitor"
116 Monitor one or more md devices and act on any state changes. This is
117 only meaningful for RAID1, 4, 5, 6, 10 or multipath arrays, as
118 only these have interesting state. RAID0 or Linear never have
119 missing, spare, or failed drives, so there is nothing to monitor.
120
121 .TP
122 .B "Grow"
123 Grow (or shrink) an array, or otherwise reshape it in some way.
124 Currently supported growth options including changing the active size
125 of component devices and changing the number of active devices in
126 Linear and RAID levels 0/1/4/5/6,
127 changing the RAID level between 0, 1, 5, and 6, and between 0 and 10,
128 changing the chunk size and layout for RAID 0,4,5,6, as well as adding or
129 removing a write-intent bitmap.
130
131 .TP
132 .B "Incremental Assembly"
133 Add a single device to an appropriate array. If the addition of the
134 device makes the array runnable, the array will be started.
135 This provides a convenient interface to a
136 .I hot-plug
137 system. As each device is detected,
138 .I mdadm
139 has a chance to include it in some array as appropriate.
140 Optionally, when the
141 .I \-\-fail
142 flag is passed in we will remove the device from any active array
143 instead of adding it.
144
145 If a
146 .B CONTAINER
147 is passed to
148 .I mdadm
149 in this mode, then any arrays within that container will be assembled
150 and started.
151
152 .TP
153 .B Manage
154 This is for doing things to specific components of an array such as
155 adding new spares and removing faulty devices.
156
157 .TP
158 .B Misc
159 This is an 'everything else' mode that supports operations on active
160 arrays, operations on component devices such as erasing old superblocks, and
161 information gathering operations.
162 .\"This mode allows operations on independent devices such as examine MD
163 .\"superblocks, erasing old superblocks and stopping active arrays.
164
165 .TP
166 .B Auto-detect
167 This mode does not act on a specific device or array, but rather it
168 requests the Linux Kernel to activate any auto-detected arrays.
169 .SH OPTIONS
170
171 .SH Options for selecting a mode are:
172
173 .TP
174 .BR \-A ", " \-\-assemble
175 Assemble a pre-existing array.
176
177 .TP
178 .BR \-B ", " \-\-build
179 Build a legacy array without superblocks.
180
181 .TP
182 .BR \-C ", " \-\-create
183 Create a new array.
184
185 .TP
186 .BR \-F ", " \-\-follow ", " \-\-monitor
187 Select
188 .B Monitor
189 mode.
190
191 .TP
192 .BR \-G ", " \-\-grow
193 Change the size or shape of an active array.
194
195 .TP
196 .BR \-I ", " \-\-incremental
197 Add/remove a single device to/from an appropriate array, and possibly start the array.
198
199 .TP
200 .B \-\-auto-detect
201 Request that the kernel starts any auto-detected arrays. This can only
202 work if
203 .I md
204 is compiled into the kernel \(em not if it is a module.
205 Arrays can be auto-detected by the kernel if all the components are in
206 primary MS-DOS partitions with partition type
207 .BR FD ,
208 and all use v0.90 metadata.
209 In-kernel autodetect is not recommended for new installations. Using
210 .I mdadm
211 to detect and assemble arrays \(em possibly in an
212 .I initrd
213 \(em is substantially more flexible and should be preferred.
214
215 .P
216 If a device is given before any options, or if the first option is
217 .BR \-\-add ,
218 .BR \-\-fail ,
219 or
220 .BR \-\-remove ,
221 then the MANAGE mode is assumed.
222 Anything other than these will cause the
223 .B Misc
224 mode to be assumed.
225
226 .SH Options that are not mode-specific are:
227
228 .TP
229 .BR \-h ", " \-\-help
230 Display general help message or, after one of the above options, a
231 mode-specific help message.
232
233 .TP
234 .B \-\-help\-options
235 Display more detailed help about command line parsing and some commonly
236 used options.
237
238 .TP
239 .BR \-V ", " \-\-version
240 Print version information for mdadm.
241
242 .TP
243 .BR \-v ", " \-\-verbose
244 Be more verbose about what is happening. This can be used twice to be
245 extra-verbose.
246 The extra verbosity currently only affects
247 .B \-\-detail \-\-scan
248 and
249 .BR "\-\-examine \-\-scan" .
250
251 .TP
252 .BR \-q ", " \-\-quiet
253 Avoid printing purely informative messages. With this,
254 .I mdadm
255 will be silent unless there is something really important to report.
256
257 .TP
258 .BR \-f ", " \-\-force
259 Be more forceful about certain operations. See the various modes for
260 the exact meaning of this option in different contexts.
261
262 .TP
263 .BR \-c ", " \-\-config=
264 Specify the config file. Default is to use
265 .BR /etc/mdadm.conf ,
266 or if that is missing then
267 .BR /etc/mdadm/mdadm.conf .
268 If the config file given is
269 .B "partitions"
270 then nothing will be read, but
271 .I mdadm
272 will act as though the config file contained exactly
273 .B "DEVICE partitions containers"
274 and will read
275 .B /proc/partitions
276 to find a list of devices to scan, and
277 .B /proc/mdstat
278 to find a list of containers to examine.
279 If the word
280 .B "none"
281 is given for the config file, then
282 .I mdadm
283 will act as though the config file were empty.
284
285 .TP
286 .BR \-s ", " \-\-scan
287 Scan config file or
288 .B /proc/mdstat
289 for missing information.
290 In general, this option gives
291 .I mdadm
292 permission to get any missing information (like component devices,
293 array devices, array identities, and alert destination) from the
294 configuration file (see previous option);
295 one exception is MISC mode when using
296 .B \-\-detail
297 or
298 .B \-\-stop,
299 in which case
300 .B \-\-scan
301 says to get a list of array devices from
302 .BR /proc/mdstat .
303
304 .TP
305 .BR \-e ", " \-\-metadata=
306 Declare the style of RAID metadata (superblock) to be used. The
307 default is {DEFAULT_METADATA} for
308 .BR \-\-create ,
309 and to guess for other operations.
310 The default can be overridden by setting the
311 .B metadata
312 value for the
313 .B CREATE
314 keyword in
315 .BR mdadm.conf .
316
317 Options are:
318 .RS
319 .ie '{DEFAULT_METADATA}'0.90'
320 .IP "0, 0.90, default"
321 .el
322 .IP "0, 0.90"
323 ..
324 Use the original 0.90 format superblock. This format limits arrays to
325 28 component devices and limits component devices of levels 1 and
326 greater to 2 terabytes. It is also possible for there to be confusion
327 about whether the superblock applies to a whole device or just the
328 last partition, if that partition starts on a 64K boundary.
329 .ie '{DEFAULT_METADATA}'0.90'
330 .IP "1, 1.0, 1.1, 1.2"
331 .el
332 .IP "1, 1.0, 1.1, 1.2 default"
333 ..
334 Use the new version-1 format superblock. This has fewer restrictions.
335 It can easily be moved between hosts with different endian-ness, and a
336 recovery operation can be checkpointed and restarted. The different
337 sub-versions store the superblock at different locations on the
338 device, either at the end (for 1.0), at the start (for 1.1) or 4K from
339 the start (for 1.2). "1" is equivalent to "1.0".
340 'if '{DEFAULT_METADATA}'1.2' "default" is equivalent to "1.2".
341 .IP ddf
342 Use the "Industry Standard" DDF (Disk Data Format) format defined by
343 SNIA.
344 When creating a DDF array a
345 .B CONTAINER
346 will be created, and normal arrays can be created in that container.
347 .IP imsm
348 Use the Intel(R) Matrix Storage Manager metadata format. This creates a
349 .B CONTAINER
350 which is managed in a similar manner to DDF, and is supported by an
351 option-rom on some platforms:
352 .IP
353 .B http://www.intel.com/design/chipsets/matrixstorage_sb.htm
354 .PP
355 .RE
356
357 .TP
358 .B \-\-homehost=
359 This will override any
360 .B HOMEHOST
361 setting in the config file and provides the identity of the host which
362 should be considered the home for any arrays.
363
364 When creating an array, the
365 .B homehost
366 will be recorded in the metadata. For version-1 superblocks, it will
367 be prefixed to the array name. For version-0.90 superblocks, part of
368 the SHA1 hash of the hostname will be stored in the later half of the
369 UUID.
370
371 When reporting information about an array, any array which is tagged
372 for the given homehost will be reported as such.
373
374 When using Auto-Assemble, only arrays tagged for the given homehost
375 will be allowed to use 'local' names (i.e. not ending in '_' followed
376 by a digit string). See below under
377 .BR "Auto Assembly" .
378
379 .SH For create, build, or grow:
380
381 .TP
382 .BR \-n ", " \-\-raid\-devices=
383 Specify the number of active devices in the array. This, plus the
384 number of spare devices (see below) must equal the number of
385 .I component-devices
386 (including "\fBmissing\fP" devices)
387 that are listed on the command line for
388 .BR \-\-create .
389 Setting a value of 1 is probably
390 a mistake and so requires that
391 .B \-\-force
392 be specified first. A value of 1 will then be allowed for linear,
393 multipath, RAID0 and RAID1. It is never allowed for RAID4, RAID5 or RAID6.
394 .br
395 This number can only be changed using
396 .B \-\-grow
397 for RAID1, RAID4, RAID5 and RAID6 arrays, and only on kernels which provide
398 the necessary support.
399
400 .TP
401 .BR \-x ", " \-\-spare\-devices=
402 Specify the number of spare (eXtra) devices in the initial array.
403 Spares can also be added
404 and removed later. The number of component devices listed
405 on the command line must equal the number of RAID devices plus the
406 number of spare devices.
407
408 .TP
409 .BR \-z ", " \-\-size=
410 Amount (in Kibibytes) of space to use from each drive in RAID levels 1/4/5/6.
411 This must be a multiple of the chunk size, and must leave about 128Kb
412 of space at the end of the drive for the RAID superblock.
413 If this is not specified
414 (as it normally is not) the smallest drive (or partition) sets the
415 size, though if there is a variance among the drives of greater than 1%, a warning is
416 issued.
417
418 A suffix of 'M' or 'G' can be given to indicate Megabytes or
419 Gigabytes respectively.
420
421 This value can be set with
422 .B \-\-grow
423 for RAID level 1/4/5/6. If the array was created with a size smaller
424 than the currently active drives, the extra space can be accessed
425 using
426 .BR \-\-grow .
427 The size can be given as
428 .B max
429 which means to choose the largest size that fits on all current drives.
430
431 Before reducing the size of the array (with
432 .BR "\-\-grow \-\-size=" )
433 you should make sure that space isn't needed. If the device holds a
434 filesystem, you would need to resize the filesystem to use less space.
435
436 After reducing the array size you should check that the data stored in
437 the device is still available. If the device holds a filesystem, then
438 an 'fsck' of the filesystem is a minimum requirement. If there are
439 problems the array can be made bigger again with no loss with another
440 .B "\-\-grow \-\-size="
441 command.
442
443 This value can not be used with
444 .B CONTAINER
445 metadata such as DDF and IMSM.
446
447 .TP
448 .BR \-Z ", " \-\-array\-size=
449 This is only meaningful with
450 .B \-\-grow
451 and its effect is not persistent: when the array is stopped and
452 restarted the default array size will be restored.
453
454 Setting the array-size causes the array to appear smaller to programs
455 that access the data. This is particularly needed before reshaping an
456 array so that it will be smaller. As the reshape is not reversible,
457 but setting the size with
458 .B \-\-array-size
459 is, it is required that the array size is reduced as appropriate
460 before the number of devices in the array is reduced.
461
462 Before reducing the size of the array you should make sure that space
463 isn't needed. If the device holds a filesystem, you would need to
464 resize the filesystem to use less space.
465
466 After reducing the array size you should check that the data stored in
467 the device is still available. If the device holds a filesystem, then
468 an 'fsck' of the filesystem is a minimum requirement. If there are
469 problems the array can be made bigger again with no loss with another
470 .B "\-\-grow \-\-array\-size="
471 command.
472
473 A suffix of 'M' or 'G' can be given to indicate Megabytes or
474 Gigabytes respectively.
475 A value of
476 .B max
477 restores the apparent size of the array to be whatever the real
478 amount of available space is.
479
480 .TP
481 .BR \-c ", " \-\-chunk=
482 Specify chunk size of kibibytes. The default when creating an
483 array is 512KB. To ensure compatibility with earlier versions, the
484 default when Building and array with no persistent metadata is 64KB.
485 This is only meaningful for RAID0, RAID4, RAID5, RAID6, and RAID10.
486
487 RAID4, RAID5, RAID6, and RAID10 require the chunk size to be a power
488 of 2. In any case it must be a multiple of 4KB.
489
490 A suffix of 'M' or 'G' can be given to indicate Megabytes or
491 Gigabytes respectively.
492
493 .TP
494 .BR \-\-rounding=
495 Specify rounding factor for a Linear array. The size of each
496 component will be rounded down to a multiple of this size.
497 This is a synonym for
498 .B \-\-chunk
499 but highlights the different meaning for Linear as compared to other
500 RAID levels. The default is 64K if a kernel earlier than 2.6.16 is in
501 use, and is 0K (i.e. no rounding) in later kernels.
502
503 .TP
504 .BR \-l ", " \-\-level=
505 Set RAID level. When used with
506 .BR \-\-create ,
507 options are: linear, raid0, 0, stripe, raid1, 1, mirror, raid4, 4,
508 raid5, 5, raid6, 6, raid10, 10, multipath, mp, faulty, container.
509 Obviously some of these are synonymous.
510
511 When a
512 .B CONTAINER
513 metadata type is requested, only the
514 .B container
515 level is permitted, and it does not need to be explicitly given.
516
517 When used with
518 .BR \-\-build ,
519 only linear, stripe, raid0, 0, raid1, multipath, mp, and faulty are valid.
520
521 Can be used with
522 .B \-\-grow
523 to change the RAID level in some cases. See LEVEL CHANGES below.
524
525 .TP
526 .BR \-p ", " \-\-layout=
527 This option configures the fine details of data layout for RAID5, RAID6,
528 and RAID10 arrays, and controls the failure modes for
529 .IR faulty .
530
531 The layout of the RAID5 parity block can be one of
532 .BR left\-asymmetric ,
533 .BR left\-symmetric ,
534 .BR right\-asymmetric ,
535 .BR right\-symmetric ,
536 .BR la ", " ra ", " ls ", " rs .
537 The default is
538 .BR left\-symmetric .
539
540 It is also possible to cause RAID5 to use a RAID4-like layout by
541 choosing
542 .BR parity\-first ,
543 or
544 .BR parity\-last .
545
546 Finally for RAID5 there are DDF\-compatible layouts,
547 .BR ddf\-zero\-restart ,
548 .BR ddf\-N\-restart ,
549 and
550 .BR ddf\-N\-continue .
551
552 These same layouts are available for RAID6. There are also 4 layouts
553 that will provide an intermediate stage for converting between RAID5
554 and RAID6. These provide a layout which is identical to the
555 corresponding RAID5 layout on the first N\-1 devices, and has the 'Q'
556 syndrome (the second 'parity' block used by RAID6) on the last device.
557 These layouts are:
558 .BR left\-symmetric\-6 ,
559 .BR right\-symmetric\-6 ,
560 .BR left\-asymmetric\-6 ,
561 .BR right\-asymmetric\-6 ,
562 and
563 .BR parity\-first\-6 .
564
565 When setting the failure mode for level
566 .I faulty,
567 the options are:
568 .BR write\-transient ", " wt ,
569 .BR read\-transient ", " rt ,
570 .BR write\-persistent ", " wp ,
571 .BR read\-persistent ", " rp ,
572 .BR write\-all ,
573 .BR read\-fixable ", " rf ,
574 .BR clear ", " flush ", " none .
575
576 Each failure mode can be followed by a number, which is used as a period
577 between fault generation. Without a number, the fault is generated
578 once on the first relevant request. With a number, the fault will be
579 generated after that many requests, and will continue to be generated
580 every time the period elapses.
581
582 Multiple failure modes can be current simultaneously by using the
583 .B \-\-grow
584 option to set subsequent failure modes.
585
586 "clear" or "none" will remove any pending or periodic failure modes,
587 and "flush" will clear any persistent faults.
588
589 Finally, the layout options for RAID10 are one of 'n', 'o' or 'f' followed
590 by a small number. The default is 'n2'. The supported options are:
591
592 .I 'n'
593 signals 'near' copies. Multiple copies of one data block are at
594 similar offsets in different devices.
595
596 .I 'o'
597 signals 'offset' copies. Rather than the chunks being duplicated
598 within a stripe, whole stripes are duplicated but are rotated by one
599 device so duplicate blocks are on different devices. Thus subsequent
600 copies of a block are in the next drive, and are one chunk further
601 down.
602
603 .I 'f'
604 signals 'far' copies
605 (multiple copies have very different offsets).
606 See md(4) for more detail about 'near', 'offset', and 'far'.
607
608 The number is the number of copies of each datablock. 2 is normal, 3
609 can be useful. This number can be at most equal to the number of
610 devices in the array. It does not need to divide evenly into that
611 number (e.g. it is perfectly legal to have an 'n2' layout for an array
612 with an odd number of devices).
613
614 When an array is converted between RAID5 and RAID6 an intermediate
615 RAID6 layout is used in which the second parity block (Q) is always on
616 the last device. To convert a RAID5 to RAID6 and leave it in this new
617 layout (which does not require re-striping) use
618 .BR \-\-layout=preserve .
619 This will try to avoid any restriping.
620
621 The converse of this is
622 .B \-\-layout=normalise
623 which will change a non-standard RAID6 layout into a more standard
624 arrangement.
625
626 .TP
627 .BR \-\-parity=
628 same as
629 .B \-\-layout
630 (thus explaining the p of
631 .BR \-p ).
632
633 .TP
634 .BR \-b ", " \-\-bitmap=
635 Specify a file to store a write-intent bitmap in. The file should not
636 exist unless
637 .B \-\-force
638 is also given. The same file should be provided
639 when assembling the array. If the word
640 .B "internal"
641 is given, then the bitmap is stored with the metadata on the array,
642 and so is replicated on all devices. If the word
643 .B "none"
644 is given with
645 .B \-\-grow
646 mode, then any bitmap that is present is removed.
647
648 To help catch typing errors, the filename must contain at least one
649 slash ('/') if it is a real file (not 'internal' or 'none').
650
651 Note: external bitmaps are only known to work on ext2 and ext3.
652 Storing bitmap files on other filesystems may result in serious problems.
653
654 .TP
655 .BR \-\-bitmap\-chunk=
656 Set the chunksize of the bitmap. Each bit corresponds to that many
657 Kilobytes of storage.
658 When using a file based bitmap, the default is to use the smallest
659 size that is at-least 4 and requires no more than 2^21 chunks.
660 When using an
661 .B internal
662 bitmap, the chunksize defaults to 64Meg, or larger if necessary to
663 fit the bitmap into the available space.
664
665 A suffix of 'M' or 'G' can be given to indicate Megabytes or
666 Gigabytes respectively.
667
668 .TP
669 .BR \-W ", " \-\-write\-mostly
670 subsequent devices listed in a
671 .BR \-\-build ,
672 .BR \-\-create ,
673 or
674 .B \-\-add
675 command will be flagged as 'write-mostly'. This is valid for RAID1
676 only and means that the 'md' driver will avoid reading from these
677 devices if at all possible. This can be useful if mirroring over a
678 slow link.
679
680 .TP
681 .BR \-\-write\-behind=
682 Specify that write-behind mode should be enabled (valid for RAID1
683 only). If an argument is specified, it will set the maximum number
684 of outstanding writes allowed. The default value is 256.
685 A write-intent bitmap is required in order to use write-behind
686 mode, and write-behind is only attempted on drives marked as
687 .IR write-mostly .
688
689 .TP
690 .BR \-\-assume\-clean
691 Tell
692 .I mdadm
693 that the array pre-existed and is known to be clean. It can be useful
694 when trying to recover from a major failure as you can be sure that no
695 data will be affected unless you actually write to the array. It can
696 also be used when creating a RAID1 or RAID10 if you want to avoid the
697 initial resync, however this practice \(em while normally safe \(em is not
698 recommended. Use this only if you really know what you are doing.
699 .IP
700 When the devices that will be part of a new array were filled
701 with zeros before creation the operator knows the array is
702 actually clean. If that is the case, such as after running
703 badblocks, this argument can be used to tell mdadm the
704 facts the operator knows.
705 .IP
706 When an array is resized to a larger size with
707 .B "\-\-grow \-\-size="
708 the new space is normally resynced in that same way that the whole
709 array is resynced at creation. From Linux version 2.6.40,
710 .B \-\-assume\-clean
711 can be used with that command to avoid the automatic resync.
712
713 .TP
714 .BR \-\-backup\-file=
715 This is needed when
716 .B \-\-grow
717 is used to increase the number of raid-devices in a RAID5 or RAID6 if
718 there are no spare devices available, or to shrink, change RAID level
719 or layout. See the GROW MODE section below on RAID\-DEVICES CHANGES.
720 The file must be stored on a separate device, not on the RAID array
721 being reshaped.
722
723 .TP
724 .BR \-N ", " \-\-name=
725 Set a
726 .B name
727 for the array. This is currently only effective when creating an
728 array with a version-1 superblock, or an array in a DDF container.
729 The name is a simple textual string that can be used to identify array
730 components when assembling. If name is needed but not specified, it
731 is taken from the basename of the device that is being created.
732 e.g. when creating
733 .I /dev/md/home
734 the
735 .B name
736 will default to
737 .IR home .
738
739 .TP
740 .BR \-R ", " \-\-run
741 Insist that
742 .I mdadm
743 run the array, even if some of the components
744 appear to be active in another array or filesystem. Normally
745 .I mdadm
746 will ask for confirmation before including such components in an
747 array. This option causes that question to be suppressed.
748
749 .TP
750 .BR \-f ", " \-\-force
751 Insist that
752 .I mdadm
753 accept the geometry and layout specified without question. Normally
754 .I mdadm
755 will not allow creation of an array with only one device, and will try
756 to create a RAID5 array with one missing drive (as this makes the
757 initial resync work faster). With
758 .BR \-\-force ,
759 .I mdadm
760 will not try to be so clever.
761
762 .TP
763 .BR \-a ", " "\-\-auto{=yes,md,mdp,part,p}{NN}"
764 Instruct mdadm how to create the device file if needed, possibly allocating
765 an unused minor number. "md" causes a non-partitionable array
766 to be used (though since Linux 2.6.28, these array devices are in fact
767 partitionable). "mdp", "part" or "p" causes a partitionable array (2.6 and
768 later) to be used. "yes" requires the named md device to have
769 a 'standard' format, and the type and minor number will be determined
770 from this. With mdadm 3.0, device creation is normally left up to
771 .I udev
772 so this option is unlikely to be needed.
773 See DEVICE NAMES below.
774
775 The argument can also come immediately after
776 "\-a". e.g. "\-ap".
777
778 If
779 .B \-\-auto
780 is not given on the command line or in the config file, then
781 the default will be
782 .BR \-\-auto=yes .
783
784 If
785 .B \-\-scan
786 is also given, then any
787 .I auto=
788 entries in the config file will override the
789 .B \-\-auto
790 instruction given on the command line.
791
792 For partitionable arrays,
793 .I mdadm
794 will create the device file for the whole array and for the first 4
795 partitions. A different number of partitions can be specified at the
796 end of this option (e.g.
797 .BR \-\-auto=p7 ).
798 If the device name ends with a digit, the partition names add a 'p',
799 and a number, e.g.
800 .IR /dev/md/home1p3 .
801 If there is no trailing digit, then the partition names just have a
802 number added, e.g.
803 .IR /dev/md/scratch3 .
804
805 If the md device name is in a 'standard' format as described in DEVICE
806 NAMES, then it will be created, if necessary, with the appropriate
807 device number based on that name. If the device name is not in one of these
808 formats, then a unused device number will be allocated. The device
809 number will be considered unused if there is no active array for that
810 number, and there is no entry in /dev for that number and with a
811 non-standard name. Names that are not in 'standard' format are only
812 allowed in "/dev/md/".
813
814 .ig XX
815 .\".TP
816 .\".BR \-\-symlink = no
817 .\"Normally when
818 .\".B \-\-auto
819 .\"causes
820 .\".I mdadm
821 .\"to create devices in
822 .\".B /dev/md/
823 .\"it will also create symlinks from
824 .\".B /dev/
825 .\"with names starting with
826 .\".B md
827 .\"or
828 .\".BR md_ .
829 .\"Use
830 .\".B \-\-symlink=no
831 .\"to suppress this, or
832 .\".B \-\-symlink=yes
833 .\"to enforce this even if it is suppressing
834 .\".IR mdadm.conf .
835 .\"
836 .XX
837
838 .SH For assemble:
839
840 .TP
841 .BR \-u ", " \-\-uuid=
842 uuid of array to assemble. Devices which don't have this uuid are
843 excluded
844
845 .TP
846 .BR \-m ", " \-\-super\-minor=
847 Minor number of device that array was created for. Devices which
848 don't have this minor number are excluded. If you create an array as
849 /dev/md1, then all superblocks will contain the minor number 1, even if
850 the array is later assembled as /dev/md2.
851
852 Giving the literal word "dev" for
853 .B \-\-super\-minor
854 will cause
855 .I mdadm
856 to use the minor number of the md device that is being assembled.
857 e.g. when assembling
858 .BR /dev/md0 ,
859 .B \-\-super\-minor=dev
860 will look for super blocks with a minor number of 0.
861
862 .B \-\-super\-minor
863 is only relevant for v0.90 metadata, and should not normally be used.
864 Using
865 .B \-\-uuid
866 is much safer.
867
868 .TP
869 .BR \-N ", " \-\-name=
870 Specify the name of the array to assemble. This must be the name
871 that was specified when creating the array. It must either match
872 the name stored in the superblock exactly, or it must match
873 with the current
874 .I homehost
875 prefixed to the start of the given name.
876
877 .TP
878 .BR \-f ", " \-\-force
879 Assemble the array even if the metadata on some devices appears to be
880 out-of-date. If
881 .I mdadm
882 cannot find enough working devices to start the array, but can find
883 some devices that are recorded as having failed, then it will mark
884 those devices as working so that the array can be started.
885 An array which requires
886 .B \-\-force
887 to be started may contain data corruption. Use it carefully.
888
889 .TP
890 .BR \-R ", " \-\-run
891 Attempt to start the array even if fewer drives were given than were
892 present last time the array was active. Normally if not all the
893 expected drives are found and
894 .B \-\-scan
895 is not used, then the array will be assembled but not started.
896 With
897 .B \-\-run
898 an attempt will be made to start it anyway.
899
900 .TP
901 .B \-\-no\-degraded
902 This is the reverse of
903 .B \-\-run
904 in that it inhibits the startup of array unless all expected drives
905 are present. This is only needed with
906 .B \-\-scan,
907 and can be used if the physical connections to devices are
908 not as reliable as you would like.
909
910 .TP
911 .BR \-a ", " "\-\-auto{=no,yes,md,mdp,part}"
912 See this option under Create and Build options.
913
914 .TP
915 .BR \-a ", " "\-\-add"
916 This option can be used in Grow mode in two cases.
917
918 If the target array is a Linear array, then
919 .B \-\-add
920 can be used to add one or more devices to the array. They
921 are simply catenated on to the end of the array. Once added, the
922 devices cannot be removed.
923
924 If the
925 .B \-\-raid\-disks
926 option is being used to increase the number of devices in an array,
927 then
928 .B \-\-add
929 can be used to add some extra devices to be included in the array.
930 In most cases this is not needed as the extra devices can be added as
931 spares first, and then the number of raid-disks can be changed.
932 However for RAID0, it is not possible to add spares. So to increase
933 the number of devices in a RAID0, it is necessary to set the new
934 number of devices, and to add the new devices, in the same command.
935
936 .TP
937 .BR \-b ", " \-\-bitmap=
938 Specify the bitmap file that was given when the array was created. If
939 an array has an
940 .B internal
941 bitmap, there is no need to specify this when assembling the array.
942
943 .TP
944 .BR \-\-backup\-file=
945 If
946 .B \-\-backup\-file
947 was used while reshaping an array (e.g. changing number of devices or
948 chunk size) and the system crashed during the critical section, then the same
949 .B \-\-backup\-file
950 must be presented to
951 .B \-\-assemble
952 to allow possibly corrupted data to be restored, and the reshape
953 to be completed.
954
955 .TP
956 .BR \-\-invalid\-backup
957 If the file needed for the above option is not available for any
958 reason an empty file can be given together with this option to
959 indicate that the backup file is invalid. In this case the data that
960 was being rearranged at the time of the crash could be irrecoverably
961 lost, but the rest of the array may still be recoverable. This option
962 should only be used as a last resort if there is no way to recover the
963 backup file.
964
965
966 .TP
967 .BR \-U ", " \-\-update=
968 Update the superblock on each device while assembling the array. The
969 argument given to this flag can be one of
970 .BR sparc2.2 ,
971 .BR summaries ,
972 .BR uuid ,
973 .BR name ,
974 .BR homehost ,
975 .BR resync ,
976 .BR byteorder ,
977 .BR devicesize ,
978 .BR no\-bitmap ,
979 or
980 .BR super\-minor .
981
982 The
983 .B sparc2.2
984 option will adjust the superblock of an array what was created on a Sparc
985 machine running a patched 2.2 Linux kernel. This kernel got the
986 alignment of part of the superblock wrong. You can use the
987 .B "\-\-examine \-\-sparc2.2"
988 option to
989 .I mdadm
990 to see what effect this would have.
991
992 The
993 .B super\-minor
994 option will update the
995 .B "preferred minor"
996 field on each superblock to match the minor number of the array being
997 assembled.
998 This can be useful if
999 .B \-\-examine
1000 reports a different "Preferred Minor" to
1001 .BR \-\-detail .
1002 In some cases this update will be performed automatically
1003 by the kernel driver. In particular the update happens automatically
1004 at the first write to an array with redundancy (RAID level 1 or
1005 greater) on a 2.6 (or later) kernel.
1006
1007 The
1008 .B uuid
1009 option will change the uuid of the array. If a UUID is given with the
1010 .B \-\-uuid
1011 option that UUID will be used as a new UUID and will
1012 .B NOT
1013 be used to help identify the devices in the array.
1014 If no
1015 .B \-\-uuid
1016 is given, a random UUID is chosen.
1017
1018 The
1019 .B name
1020 option will change the
1021 .I name
1022 of the array as stored in the superblock. This is only supported for
1023 version-1 superblocks.
1024
1025 The
1026 .B homehost
1027 option will change the
1028 .I homehost
1029 as recorded in the superblock. For version-0 superblocks, this is the
1030 same as updating the UUID.
1031 For version-1 superblocks, this involves updating the name.
1032
1033 The
1034 .B resync
1035 option will cause the array to be marked
1036 .I dirty
1037 meaning that any redundancy in the array (e.g. parity for RAID5,
1038 copies for RAID1) may be incorrect. This will cause the RAID system
1039 to perform a "resync" pass to make sure that all redundant information
1040 is correct.
1041
1042 The
1043 .B byteorder
1044 option allows arrays to be moved between machines with different
1045 byte-order.
1046 When assembling such an array for the first time after a move, giving
1047 .B "\-\-update=byteorder"
1048 will cause
1049 .I mdadm
1050 to expect superblocks to have their byteorder reversed, and will
1051 correct that order before assembling the array. This is only valid
1052 with original (Version 0.90) superblocks.
1053
1054 The
1055 .B summaries
1056 option will correct the summaries in the superblock. That is the
1057 counts of total, working, active, failed, and spare devices.
1058
1059 The
1060 .B devicesize
1061 option will rarely be of use. It applies to version 1.1 and 1.2 metadata
1062 only (where the metadata is at the start of the device) and is only
1063 useful when the component device has changed size (typically become
1064 larger). The version 1 metadata records the amount of the device that
1065 can be used to store data, so if a device in a version 1.1 or 1.2
1066 array becomes larger, the metadata will still be visible, but the
1067 extra space will not. In this case it might be useful to assemble the
1068 array with
1069 .BR \-\-update=devicesize .
1070 This will cause
1071 .I mdadm
1072 to determine the maximum usable amount of space on each device and
1073 update the relevant field in the metadata.
1074
1075 The
1076 .B no\-bitmap
1077 option can be used when an array has an internal bitmap which is
1078 corrupt in some way so that assembling the array normally fails. It
1079 will cause any internal bitmap to be ignored.
1080
1081 .SH For Manage mode:
1082
1083 .TP
1084 .BR \-t ", " \-\-test
1085 Unless a more serious error occurred,
1086 .I mdadm
1087 will exit with a status of 2 if no changes were made to the array and
1088 0 if at least one change was made.
1089 This can be useful when an indirect specifier such as
1090 .BR missing ,
1091 .B detached
1092 or
1093 .B faulty
1094 is used in requesting an operation on the array.
1095 .B \-\-test
1096 will report failure if these specifiers didn't find any match.
1097
1098 .TP
1099 .BR \-a ", " \-\-add
1100 hot-add listed devices.
1101 If a device appears to have recently been part of the array
1102 (possibly it failed or was removed) the device is re\-added as describe
1103 in the next point.
1104 If that fails or the device was never part of the array, the device is
1105 added as a hot-spare.
1106 If the array is degraded, it will immediately start to rebuild data
1107 onto that spare.
1108
1109 Note that this and the following options are only meaningful on array
1110 with redundancy. They don't apply to RAID0 or Linear.
1111
1112 .TP
1113 .BR \-\-re\-add
1114 re\-add a device that was previous removed from an array.
1115 If the metadata on the device reports that it is a member of the
1116 array, and the slot that it used is still vacant, then the device will
1117 be added back to the array in the same position. This will normally
1118 cause the data for that device to be recovered. However based on the
1119 event count on the device, the recovery may only require sections that
1120 are flagged a write-intent bitmap to be recovered or may not require
1121 any recovery at all.
1122
1123 When used on an array that has no metadata (i.e. it was built with
1124 .BR \-\-build)
1125 it will be assumed that bitmap-based recovery is enough to make the
1126 device fully consistent with the array.
1127
1128 When
1129 .B \-\-re\-add
1130 can be accompanied by
1131 .BR \-\-update=devicesize .
1132 See the description of this option when used in Assemble mode for an
1133 explanation of its use.
1134
1135 If the device name given is
1136 .B missing
1137 then mdadm will try to find any device that looks like it should be
1138 part of the array but isn't and will try to re\-add all such devices.
1139
1140 .TP
1141 .BR \-r ", " \-\-remove
1142 remove listed devices. They must not be active. i.e. they should
1143 be failed or spare devices. As well as the name of a device file
1144 (e.g.
1145 .BR /dev/sda1 )
1146 the words
1147 .B failed
1148 and
1149 .B detached
1150 can be given to
1151 .BR \-\-remove .
1152 The first causes all failed device to be removed. The second causes
1153 any device which is no longer connected to the system (i.e an 'open'
1154 returns
1155 .BR ENXIO )
1156 to be removed. This will only succeed for devices that are spares or
1157 have already been marked as failed.
1158
1159 .TP
1160 .BR \-f ", " \-\-fail
1161 mark listed devices as faulty.
1162 As well as the name of a device file, the word
1163 .B detached
1164 can be given. This will cause any device that has been detached from
1165 the system to be marked as failed. It can then be removed.
1166
1167 .TP
1168 .BR \-\-set\-faulty
1169 same as
1170 .BR \-\-fail .
1171
1172 .TP
1173 .BR \-\-write\-mostly
1174 Subsequent devices that are added or re\-added will have the 'write-mostly'
1175 flag set. This is only valid for RAID1 and means that the 'md' driver
1176 will avoid reading from these devices if possible.
1177 .TP
1178 .BR \-\-readwrite
1179 Subsequent devices that are added or re\-added will have the 'write-mostly'
1180 flag cleared.
1181
1182 .P
1183 Each of these options requires that the first device listed is the array
1184 to be acted upon, and the remainder are component devices to be added,
1185 removed, marked as faulty, etc. Several different operations can be
1186 specified for different devices, e.g.
1187 .in +5
1188 mdadm /dev/md0 \-\-add /dev/sda1 \-\-fail /dev/sdb1 \-\-remove /dev/sdb1
1189 .in -5
1190 Each operation applies to all devices listed until the next
1191 operation.
1192
1193 If an array is using a write-intent bitmap, then devices which have
1194 been removed can be re\-added in a way that avoids a full
1195 reconstruction but instead just updates the blocks that have changed
1196 since the device was removed. For arrays with persistent metadata
1197 (superblocks) this is done automatically. For arrays created with
1198 .B \-\-build
1199 mdadm needs to be told that this device we removed recently with
1200 .BR \-\-re\-add .
1201
1202 Devices can only be removed from an array if they are not in active
1203 use, i.e. that must be spares or failed devices. To remove an active
1204 device, it must first be marked as
1205 .B faulty.
1206
1207 .SH For Misc mode:
1208
1209 .TP
1210 .BR \-Q ", " \-\-query
1211 Examine a device to see
1212 (1) if it is an md device and (2) if it is a component of an md
1213 array.
1214 Information about what is discovered is presented.
1215
1216 .TP
1217 .BR \-D ", " \-\-detail
1218 Print details of one or more md devices.
1219
1220 .TP
1221 .BR \-\-detail\-platform
1222 Print details of the platform's RAID capabilities (firmware / hardware
1223 topology) for a given metadata format.
1224
1225 .TP
1226 .BR \-Y ", " \-\-export
1227 When used with
1228 .B \-\-detail
1229 or
1230 .BR \-\-examine ,
1231 output will be formatted as
1232 .B key=value
1233 pairs for easy import into the environment.
1234
1235 .TP
1236 .BR \-E ", " \-\-examine
1237 Print contents of the metadata stored on the named device(s).
1238 Note the contrast between
1239 .B \-\-examine
1240 and
1241 .BR \-\-detail .
1242 .B \-\-examine
1243 applies to devices which are components of an array, while
1244 .B \-\-detail
1245 applies to a whole array which is currently active.
1246 .TP
1247 .B \-\-sparc2.2
1248 If an array was created on a SPARC machine with a 2.2 Linux kernel
1249 patched with RAID support, the superblock will have been created
1250 incorrectly, or at least incompatibly with 2.4 and later kernels.
1251 Using the
1252 .B \-\-sparc2.2
1253 flag with
1254 .B \-\-examine
1255 will fix the superblock before displaying it. If this appears to do
1256 the right thing, then the array can be successfully assembled using
1257 .BR "\-\-assemble \-\-update=sparc2.2" .
1258
1259 .TP
1260 .BR \-X ", " \-\-examine\-bitmap
1261 Report information about a bitmap file.
1262 The argument is either an external bitmap file or an array component
1263 in case of an internal bitmap. Note that running this on an array
1264 device (e.g.
1265 .BR /dev/md0 )
1266 does not report the bitmap for that array.
1267
1268 .TP
1269 .BR \-R ", " \-\-run
1270 start a partially assembled array. If
1271 .B \-\-assemble
1272 did not find enough devices to fully start the array, it might leaving
1273 it partially assembled. If you wish, you can then use
1274 .B \-\-run
1275 to start the array in degraded mode.
1276
1277 .TP
1278 .BR \-S ", " \-\-stop
1279 deactivate array, releasing all resources.
1280
1281 .TP
1282 .BR \-o ", " \-\-readonly
1283 mark array as readonly.
1284
1285 .TP
1286 .BR \-w ", " \-\-readwrite
1287 mark array as readwrite.
1288
1289 .TP
1290 .B \-\-zero\-superblock
1291 If the device contains a valid md superblock, the block is
1292 overwritten with zeros. With
1293 .B \-\-force
1294 the block where the superblock would be is overwritten even if it
1295 doesn't appear to be valid.
1296
1297 .TP
1298 .B \-\-kill\-subarray=
1299 If the device is a container and the argument to \-\-kill\-subarray
1300 specifies an inactive subarray in the container, then the subarray is
1301 deleted. Deleting all subarrays will leave an 'empty-container' or
1302 spare superblock on the drives. See \-\-zero\-superblock for completely
1303 removing a superblock. Note that some formats depend on the subarray
1304 index for generating a UUID, this command will fail if it would change
1305 the UUID of an active subarray.
1306
1307 .TP
1308 .B \-\-update\-subarray=
1309 If the device is a container and the argument to \-\-update\-subarray
1310 specifies a subarray in the container, then attempt to update the given
1311 superblock field in the subarray. See below in
1312 .B MISC MODE
1313 for details.
1314
1315 .TP
1316 .BR \-t ", " \-\-test
1317 When used with
1318 .BR \-\-detail ,
1319 the exit status of
1320 .I mdadm
1321 is set to reflect the status of the device. See below in
1322 .B MISC MODE
1323 for details.
1324
1325 .TP
1326 .BR \-W ", " \-\-wait
1327 For each md device given, wait for any resync, recovery, or reshape
1328 activity to finish before returning.
1329 .I mdadm
1330 will return with success if it actually waited for every device
1331 listed, otherwise it will return failure.
1332
1333 .TP
1334 .BR \-\-wait\-clean
1335 For each md device given, or each device in /proc/mdstat if
1336 .B \-\-scan
1337 is given, arrange for the array to be marked clean as soon as possible.
1338 .I mdadm
1339 will return with success if the array uses external metadata and we
1340 successfully waited. For native arrays this returns immediately as the
1341 kernel handles dirty-clean transitions at shutdown. No action is taken
1342 if safe-mode handling is disabled.
1343
1344 .SH For Incremental Assembly mode:
1345 .TP
1346 .BR \-\-rebuild\-map ", " \-r
1347 Rebuild the map file
1348 .RB ( /var/run/mdadm/map )
1349 that
1350 .I mdadm
1351 uses to help track which arrays are currently being assembled.
1352
1353 .TP
1354 .BR \-\-run ", " \-R
1355 Run any array assembled as soon as a minimal number of devices are
1356 available, rather than waiting until all expected devices are present.
1357
1358 .TP
1359 .BR \-\-scan ", " \-s
1360 Only meaningful with
1361 .B \-R
1362 this will scan the
1363 .B map
1364 file for arrays that are being incrementally assembled and will try to
1365 start any that are not already started. If any such array is listed
1366 in
1367 .B mdadm.conf
1368 as requiring an external bitmap, that bitmap will be attached first.
1369
1370 .TP
1371 .BR \-\-fail ", " \-f
1372 This allows the hot-plug system to remove devices that have fully disappeared
1373 from the kernel. It will first fail and then remove the device from any
1374 array it belongs to.
1375 The device name given should be a kernel device name such as "sda",
1376 not a name in
1377 .IR /dev .
1378
1379 .TP
1380 .BR \-\-path=
1381 Only used with \-\-fail. The 'path' given will be recorded so that if
1382 a new device appears at the same location it can be automatically
1383 added to the same array. This allows the failed device to be
1384 automatically replaced by a new device without metadata if it appears
1385 at specified path. This option is normally only set by a
1386 .I udev
1387 script.
1388
1389 .SH For Monitor mode:
1390 .TP
1391 .BR \-m ", " \-\-mail
1392 Give a mail address to send alerts to.
1393
1394 .TP
1395 .BR \-p ", " \-\-program ", " \-\-alert
1396 Give a program to be run whenever an event is detected.
1397
1398 .TP
1399 .BR \-y ", " \-\-syslog
1400 Cause all events to be reported through 'syslog'. The messages have
1401 facility of 'daemon' and varying priorities.
1402
1403 .TP
1404 .BR \-d ", " \-\-delay
1405 Give a delay in seconds.
1406 .I mdadm
1407 polls the md arrays and then waits this many seconds before polling
1408 again. The default is 60 seconds. Since 2.6.16, there is no need to
1409 reduce this as the kernel alerts
1410 .I mdadm
1411 immediately when there is any change.
1412
1413 .TP
1414 .BR \-r ", " \-\-increment
1415 Give a percentage increment.
1416 .I mdadm
1417 will generate RebuildNN events with the given percentage increment.
1418
1419 .TP
1420 .BR \-f ", " \-\-daemonise
1421 Tell
1422 .I mdadm
1423 to run as a background daemon if it decides to monitor anything. This
1424 causes it to fork and run in the child, and to disconnect from the
1425 terminal. The process id of the child is written to stdout.
1426 This is useful with
1427 .B \-\-scan
1428 which will only continue monitoring if a mail address or alert program
1429 is found in the config file.
1430
1431 .TP
1432 .BR \-i ", " \-\-pid\-file
1433 When
1434 .I mdadm
1435 is running in daemon mode, write the pid of the daemon process to
1436 the specified file, instead of printing it on standard output.
1437
1438 .TP
1439 .BR \-1 ", " \-\-oneshot
1440 Check arrays only once. This will generate
1441 .B NewArray
1442 events and more significantly
1443 .B DegradedArray
1444 and
1445 .B SparesMissing
1446 events. Running
1447 .in +5
1448 .B " mdadm \-\-monitor \-\-scan \-1"
1449 .in -5
1450 from a cron script will ensure regular notification of any degraded arrays.
1451
1452 .TP
1453 .BR \-t ", " \-\-test
1454 Generate a
1455 .B TestMessage
1456 alert for every array found at startup. This alert gets mailed and
1457 passed to the alert program. This can be used for testing that alert
1458 message do get through successfully.
1459
1460 .TP
1461 .BR \-\-no\-sharing
1462 This inhibits the functionality for moving spares between arrays.
1463 Only one monitoring process started with
1464 .B \-\-scan
1465 but without this flag is allowed, otherwise the two could interfere
1466 with each other.
1467
1468 .SH ASSEMBLE MODE
1469
1470 .HP 12
1471 Usage:
1472 .B mdadm \-\-assemble
1473 .I md-device options-and-component-devices...
1474 .HP 12
1475 Usage:
1476 .B mdadm \-\-assemble \-\-scan
1477 .I md-devices-and-options...
1478 .HP 12
1479 Usage:
1480 .B mdadm \-\-assemble \-\-scan
1481 .I options...
1482
1483 .PP
1484 This usage assembles one or more RAID arrays from pre-existing components.
1485 For each array, mdadm needs to know the md device, the identity of the
1486 array, and a number of component-devices. These can be found in a number of ways.
1487
1488 In the first usage example (without the
1489 .BR \-\-scan )
1490 the first device given is the md device.
1491 In the second usage example, all devices listed are treated as md
1492 devices and assembly is attempted.
1493 In the third (where no devices are listed) all md devices that are
1494 listed in the configuration file are assembled. If not arrays are
1495 described by the configuration file, then any arrays that
1496 can be found on unused devices will be assembled.
1497
1498 If precisely one device is listed, but
1499 .B \-\-scan
1500 is not given, then
1501 .I mdadm
1502 acts as though
1503 .B \-\-scan
1504 was given and identity information is extracted from the configuration file.
1505
1506 The identity can be given with the
1507 .B \-\-uuid
1508 option, the
1509 .B \-\-name
1510 option, or the
1511 .B \-\-super\-minor
1512 option, will be taken from the md-device record in the config file, or
1513 will be taken from the super block of the first component-device
1514 listed on the command line.
1515
1516 Devices can be given on the
1517 .B \-\-assemble
1518 command line or in the config file. Only devices which have an md
1519 superblock which contains the right identity will be considered for
1520 any array.
1521
1522 The config file is only used if explicitly named with
1523 .B \-\-config
1524 or requested with (a possibly implicit)
1525 .BR \-\-scan .
1526 In the later case,
1527 .B /etc/mdadm.conf
1528 or
1529 .B /etc/mdadm/mdadm.conf
1530 is used.
1531
1532 If
1533 .B \-\-scan
1534 is not given, then the config file will only be used to find the
1535 identity of md arrays.
1536
1537 Normally the array will be started after it is assembled. However if
1538 .B \-\-scan
1539 is not given and not all expected drives were listed, then the array
1540 is not started (to guard against usage errors). To insist that the
1541 array be started in this case (as may work for RAID1, 4, 5, 6, or 10),
1542 give the
1543 .B \-\-run
1544 flag.
1545
1546 If
1547 .I udev
1548 is active,
1549 .I mdadm
1550 does not create any entries in
1551 .B /dev
1552 but leaves that to
1553 .IR udev .
1554 It does record information in
1555 .B /var/run/mdadm/map
1556 which will allow
1557 .I udev
1558 to choose the correct name.
1559
1560 If
1561 .I mdadm
1562 detects that udev is not configured, it will create the devices in
1563 .B /dev
1564 itself.
1565
1566 In Linux kernels prior to version 2.6.28 there were two distinctly
1567 different types of md devices that could be created: one that could be
1568 partitioned using standard partitioning tools and one that could not.
1569 Since 2.6.28 that distinction is no longer relevant as both type of
1570 devices can be partitioned.
1571 .I mdadm
1572 will normally create the type that originally could not be partitioned
1573 as it has a well defined major number (9).
1574
1575 Prior to 2.6.28, it is important that mdadm chooses the correct type
1576 of array device to use. This can be controlled with the
1577 .B \-\-auto
1578 option. In particular, a value of "mdp" or "part" or "p" tells mdadm
1579 to use a partitionable device rather than the default.
1580
1581 In the no-udev case, the value given to
1582 .B \-\-auto
1583 can be suffixed by a number. This tells
1584 .I mdadm
1585 to create that number of partition devices rather than the default of 4.
1586
1587 The value given to
1588 .B \-\-auto
1589 can also be given in the configuration file as a word starting
1590 .B auto=
1591 on the ARRAY line for the relevant array.
1592
1593 .SS Auto Assembly
1594 When
1595 .B \-\-assemble
1596 is used with
1597 .B \-\-scan
1598 and no devices are listed,
1599 .I mdadm
1600 will first attempt to assemble all the arrays listed in the config
1601 file.
1602
1603 In no array at listed in the config (other than those marked
1604 .BR <ignore> )
1605 it will look through the available devices for possible arrays and
1606 will try to assemble anything that it finds. Arrays which are tagged
1607 as belonging to the given homehost will be assembled and started
1608 normally. Arrays which do not obviously belong to this host are given
1609 names that are expected not to conflict with anything local, and are
1610 started "read-auto" so that nothing is written to any device until the
1611 array is written to. i.e. automatic resync etc is delayed.
1612
1613 If
1614 .I mdadm
1615 finds a consistent set of devices that look like they should comprise
1616 an array, and if the superblock is tagged as belonging to the given
1617 home host, it will automatically choose a device name and try to
1618 assemble the array. If the array uses version-0.90 metadata, then the
1619 .B minor
1620 number as recorded in the superblock is used to create a name in
1621 .B /dev/md/
1622 so for example
1623 .BR /dev/md/3 .
1624 If the array uses version-1 metadata, then the
1625 .B name
1626 from the superblock is used to similarly create a name in
1627 .B /dev/md/
1628 (the name will have any 'host' prefix stripped first).
1629
1630 This behaviour can be modified by the
1631 .I AUTO
1632 line in the
1633 .I mdadm.conf
1634 configuration file. This line can indicate that specific metadata
1635 type should, or should not, be automatically assembled. If an array
1636 is found which is not listed in
1637 .I mdadm.conf
1638 and has a metadata format that is denied by the
1639 .I AUTO
1640 line, then it will not be assembled.
1641 The
1642 .I AUTO
1643 line can also request that all arrays identified as being for this
1644 homehost should be assembled regardless of their metadata type.
1645 See
1646 .IR mdadm.conf (5)
1647 for further details.
1648
1649 Note: Auto assembly cannot be used for assembling and activating some
1650 arrays which are undergoing reshape. In particular as the
1651 .B backup\-file
1652 cannot be given, any reshape which requires a backup-file to continue
1653 cannot be started by auto assembly. An array which is growing to more
1654 devices and has passed the critical section can be assembled using
1655 auto-assembly.
1656
1657 .SH BUILD MODE
1658
1659 .HP 12
1660 Usage:
1661 .B mdadm \-\-build
1662 .I md-device
1663 .BI \-\-chunk= X
1664 .BI \-\-level= Y
1665 .BI \-\-raid\-devices= Z
1666 .I devices
1667
1668 .PP
1669 This usage is similar to
1670 .BR \-\-create .
1671 The difference is that it creates an array without a superblock. With
1672 these arrays there is no difference between initially creating the array and
1673 subsequently assembling the array, except that hopefully there is useful
1674 data there in the second case.
1675
1676 The level may raid0, linear, raid1, raid10, multipath, or faulty, or
1677 one of their synonyms. All devices must be listed and the array will
1678 be started once complete. It will often be appropriate to use
1679 .B \-\-assume\-clean
1680 with levels raid1 or raid10.
1681
1682 .SH CREATE MODE
1683
1684 .HP 12
1685 Usage:
1686 .B mdadm \-\-create
1687 .I md-device
1688 .BI \-\-chunk= X
1689 .BI \-\-level= Y
1690 .br
1691 .BI \-\-raid\-devices= Z
1692 .I devices
1693
1694 .PP
1695 This usage will initialise a new md array, associate some devices with
1696 it, and activate the array.
1697
1698 The named device will normally not exist when
1699 .I "mdadm \-\-create"
1700 is run, but will be created by
1701 .I udev
1702 once the array becomes active.
1703
1704 As devices are added, they are checked to see if they contain RAID
1705 superblocks or filesystems. They are also checked to see if the variance in
1706 device size exceeds 1%.
1707
1708 If any discrepancy is found, the array will not automatically be run, though
1709 the presence of a
1710 .B \-\-run
1711 can override this caution.
1712
1713 To create a "degraded" array in which some devices are missing, simply
1714 give the word "\fBmissing\fP"
1715 in place of a device name. This will cause
1716 .I mdadm
1717 to leave the corresponding slot in the array empty.
1718 For a RAID4 or RAID5 array at most one slot can be
1719 "\fBmissing\fP"; for a RAID6 array at most two slots.
1720 For a RAID1 array, only one real device needs to be given. All of the
1721 others can be
1722 "\fBmissing\fP".
1723
1724 When creating a RAID5 array,
1725 .I mdadm
1726 will automatically create a degraded array with an extra spare drive.
1727 This is because building the spare into a degraded array is in general
1728 faster than resyncing the parity on a non-degraded, but not clean,
1729 array. This feature can be overridden with the
1730 .B \-\-force
1731 option.
1732
1733 When creating an array with version-1 metadata a name for the array is
1734 required.
1735 If this is not given with the
1736 .B \-\-name
1737 option,
1738 .I mdadm
1739 will choose a name based on the last component of the name of the
1740 device being created. So if
1741 .B /dev/md3
1742 is being created, then the name
1743 .B 3
1744 will be chosen.
1745 If
1746 .B /dev/md/home
1747 is being created, then the name
1748 .B home
1749 will be used.
1750
1751 When creating a partition based array, using
1752 .I mdadm
1753 with version-1.x metadata, the partition type should be set to
1754 .B 0xDA
1755 (non fs-data). This type selection allows for greater precision since
1756 using any other [RAID auto-detect (0xFD) or a GNU/Linux partition (0x83)],
1757 might create problems in the event of array recovery through a live cdrom.
1758
1759 A new array will normally get a randomly assigned 128bit UUID which is
1760 very likely to be unique. If you have a specific need, you can choose
1761 a UUID for the array by giving the
1762 .B \-\-uuid=
1763 option. Be warned that creating two arrays with the same UUID is a
1764 recipe for disaster. Also, using
1765 .B \-\-uuid=
1766 when creating a v0.90 array will silently override any
1767 .B \-\-homehost=
1768 setting.
1769 .\"If the
1770 .\".B \-\-size
1771 .\"option is given, it is not necessary to list any component-devices in this command.
1772 .\"They can be added later, before a
1773 .\".B \-\-run.
1774 .\"If no
1775 .\".B \-\-size
1776 .\"is given, the apparent size of the smallest drive given is used.
1777
1778 When creating an array within a
1779 .B CONTAINER
1780 .I mdadm
1781 can be given either the list of devices to use, or simply the name of
1782 the container. The former case gives control over which devices in
1783 the container will be used for the array. The latter case allows
1784 .I mdadm
1785 to automatically choose which devices to use based on how much spare
1786 space is available.
1787
1788 The General Management options that are valid with
1789 .B \-\-create
1790 are:
1791 .TP
1792 .B \-\-run
1793 insist on running the array even if some devices look like they might
1794 be in use.
1795
1796 .TP
1797 .B \-\-readonly
1798 start the array readonly \(em not supported yet.
1799
1800 .SH MANAGE MODE
1801 .HP 12
1802 Usage:
1803 .B mdadm
1804 .I device
1805 .I options... devices...
1806 .PP
1807
1808 This usage will allow individual devices in an array to be failed,
1809 removed or added. It is possible to perform multiple operations with
1810 on command. For example:
1811 .br
1812 .B " mdadm /dev/md0 \-f /dev/hda1 \-r /dev/hda1 \-a /dev/hda1"
1813 .br
1814 will firstly mark
1815 .B /dev/hda1
1816 as faulty in
1817 .B /dev/md0
1818 and will then remove it from the array and finally add it back
1819 in as a spare. However only one md array can be affected by a single
1820 command.
1821
1822 When a device is added to an active array, mdadm checks to see if it
1823 has metadata on it which suggests that it was recently a member of the
1824 array. If it does, it tries to "re\-add" the device. If there have
1825 been no changes since the device was removed, or if the array has a
1826 write-intent bitmap which has recorded whatever changes there were,
1827 then the device will immediately become a full member of the array and
1828 those differences recorded in the bitmap will be resolved.
1829
1830 .SH MISC MODE
1831 .HP 12
1832 Usage:
1833 .B mdadm
1834 .I options ...
1835 .I devices ...
1836 .PP
1837
1838 MISC mode includes a number of distinct operations that
1839 operate on distinct devices. The operations are:
1840 .TP
1841 .B \-\-query
1842 The device is examined to see if it is
1843 (1) an active md array, or
1844 (2) a component of an md array.
1845 The information discovered is reported.
1846
1847 .TP
1848 .B \-\-detail
1849 The device should be an active md device.
1850 .B mdadm
1851 will display a detailed description of the array.
1852 .B \-\-brief
1853 or
1854 .B \-\-scan
1855 will cause the output to be less detailed and the format to be
1856 suitable for inclusion in
1857 .BR mdadm.conf .
1858 The exit status of
1859 .I mdadm
1860 will normally be 0 unless
1861 .I mdadm
1862 failed to get useful information about the device(s); however, if the
1863 .B \-\-test
1864 option is given, then the exit status will be:
1865 .RS
1866 .TP
1867 0
1868 The array is functioning normally.
1869 .TP
1870 1
1871 The array has at least one failed device.
1872 .TP
1873 2
1874 The array has multiple failed devices such that it is unusable.
1875 .TP
1876 4
1877 There was an error while trying to get information about the device.
1878 .RE
1879
1880 .TP
1881 .B \-\-detail\-platform
1882 Print detail of the platform's RAID capabilities (firmware / hardware
1883 topology). If the metadata is specified with
1884 .B \-e
1885 or
1886 .B \-\-metadata=
1887 then the return status will be:
1888 .RS
1889 .TP
1890 0
1891 metadata successfully enumerated its platform components on this system
1892 .TP
1893 1
1894 metadata is platform independent
1895 .TP
1896 2
1897 metadata failed to find its platform components on this system
1898 .RE
1899
1900 .TP
1901 .B \-\-update\-subarray=
1902 If the device is a container and the argument to \-\-update\-subarray
1903 specifies a subarray in the container, then attempt to update the given
1904 superblock field in the subarray. Similar to updating an array in
1905 "assemble" mode, the field to update is selected by
1906 .B \-U
1907 or
1908 .B \-\-update=
1909 option. Currently only
1910 .B name
1911 is supported.
1912
1913 The
1914 .B name
1915 option updates the subarray name in the metadata, it may not affect the
1916 device node name or the device node symlink until the subarray is
1917 re\-assembled. If updating
1918 .B name
1919 would change the UUID of an active subarray this operation is blocked,
1920 and the command will end in an error.
1921
1922 .TP
1923 .B \-\-examine
1924 The device should be a component of an md array.
1925 .I mdadm
1926 will read the md superblock of the device and display the contents.
1927 If
1928 .B \-\-brief
1929 or
1930 .B \-\-scan
1931 is given, then multiple devices that are components of the one array
1932 are grouped together and reported in a single entry suitable
1933 for inclusion in
1934 .BR mdadm.conf .
1935
1936 Having
1937 .B \-\-scan
1938 without listing any devices will cause all devices listed in the
1939 config file to be examined.
1940
1941 .TP
1942 .B \-\-stop
1943 The devices should be active md arrays which will be deactivated, as
1944 long as they are not currently in use.
1945
1946 .TP
1947 .B \-\-run
1948 This will fully activate a partially assembled md array.
1949
1950 .TP
1951 .B \-\-readonly
1952 This will mark an active array as read-only, providing that it is
1953 not currently being used.
1954
1955 .TP
1956 .B \-\-readwrite
1957 This will change a
1958 .B readonly
1959 array back to being read/write.
1960
1961 .TP
1962 .B \-\-scan
1963 For all operations except
1964 .BR \-\-examine ,
1965 .B \-\-scan
1966 will cause the operation to be applied to all arrays listed in
1967 .BR /proc/mdstat .
1968 For
1969 .BR \-\-examine,
1970 .B \-\-scan
1971 causes all devices listed in the config file to be examined.
1972
1973 .TP
1974 .BR \-b ", " \-\-brief
1975 Be less verbose. This is used with
1976 .B \-\-detail
1977 and
1978 .BR \-\-examine .
1979 Using
1980 .B \-\-brief
1981 with
1982 .B \-\-verbose
1983 gives an intermediate level of verbosity.
1984
1985 .SH MONITOR MODE
1986
1987 .HP 12
1988 Usage:
1989 .B mdadm \-\-monitor
1990 .I options... devices...
1991
1992 .PP
1993 This usage causes
1994 .I mdadm
1995 to periodically poll a number of md arrays and to report on any events
1996 noticed.
1997 .I mdadm
1998 will never exit once it decides that there are arrays to be checked,
1999 so it should normally be run in the background.
2000
2001 As well as reporting events,
2002 .I mdadm
2003 may move a spare drive from one array to another if they are in the
2004 same
2005 .B spare-group
2006 or
2007 .B domain
2008 and if the destination array has a failed drive but no spares.
2009
2010 If any devices are listed on the command line,
2011 .I mdadm
2012 will only monitor those devices. Otherwise all arrays listed in the
2013 configuration file will be monitored. Further, if
2014 .B \-\-scan
2015 is given, then any other md devices that appear in
2016 .B /proc/mdstat
2017 will also be monitored.
2018
2019 The result of monitoring the arrays is the generation of events.
2020 These events are passed to a separate program (if specified) and may
2021 be mailed to a given E-mail address.
2022
2023 When passing events to a program, the program is run once for each event,
2024 and is given 2 or 3 command-line arguments: the first is the
2025 name of the event (see below), the second is the name of the
2026 md device which is affected, and the third is the name of a related
2027 device if relevant (such as a component device that has failed).
2028
2029 If
2030 .B \-\-scan
2031 is given, then a program or an E-mail address must be specified on the
2032 command line or in the config file. If neither are available, then
2033 .I mdadm
2034 will not monitor anything.
2035 Without
2036 .B \-\-scan,
2037 .I mdadm
2038 will continue monitoring as long as something was found to monitor. If
2039 no program or email is given, then each event is reported to
2040 .BR stdout .
2041
2042 The different events are:
2043
2044 .RS 4
2045 .TP
2046 .B DeviceDisappeared
2047 An md array which previously was configured appears to no longer be
2048 configured. (syslog priority: Critical)
2049
2050 If
2051 .I mdadm
2052 was told to monitor an array which is RAID0 or Linear, then it will
2053 report
2054 .B DeviceDisappeared
2055 with the extra information
2056 .BR Wrong-Level .
2057 This is because RAID0 and Linear do not support the device-failed,
2058 hot-spare and resync operations which are monitored.
2059
2060 .TP
2061 .B RebuildStarted
2062 An md array started reconstruction. (syslog priority: Warning)
2063
2064 .TP
2065 .BI Rebuild NN
2066 Where
2067 .I NN
2068 is a two-digit number (ie. 05, 48). This indicates that rebuild
2069 has passed that many percent of the total. The events are generated
2070 with fixed increment since 0. Increment size may be specified with
2071 a commandline option (default is 20). (syslog priority: Warning)
2072
2073 .TP
2074 .B RebuildFinished
2075 An md array that was rebuilding, isn't any more, either because it
2076 finished normally or was aborted. (syslog priority: Warning)
2077
2078 .TP
2079 .B Fail
2080 An active component device of an array has been marked as
2081 faulty. (syslog priority: Critical)
2082
2083 .TP
2084 .B FailSpare
2085 A spare component device which was being rebuilt to replace a faulty
2086 device has failed. (syslog priority: Critical)
2087
2088 .TP
2089 .B SpareActive
2090 A spare component device which was being rebuilt to replace a faulty
2091 device has been successfully rebuilt and has been made active.
2092 (syslog priority: Info)
2093
2094 .TP
2095 .B NewArray
2096 A new md array has been detected in the
2097 .B /proc/mdstat
2098 file. (syslog priority: Info)
2099
2100 .TP
2101 .B DegradedArray
2102 A newly noticed array appears to be degraded. This message is not
2103 generated when
2104 .I mdadm
2105 notices a drive failure which causes degradation, but only when
2106 .I mdadm
2107 notices that an array is degraded when it first sees the array.
2108 (syslog priority: Critical)
2109
2110 .TP
2111 .B MoveSpare
2112 A spare drive has been moved from one array in a
2113 .B spare-group
2114 or
2115 .B domain
2116 to another to allow a failed drive to be replaced.
2117 (syslog priority: Info)
2118
2119 .TP
2120 .B SparesMissing
2121 If
2122 .I mdadm
2123 has been told, via the config file, that an array should have a certain
2124 number of spare devices, and
2125 .I mdadm
2126 detects that it has fewer than this number when it first sees the
2127 array, it will report a
2128 .B SparesMissing
2129 message.
2130 (syslog priority: Warning)
2131
2132 .TP
2133 .B TestMessage
2134 An array was found at startup, and the
2135 .B \-\-test
2136 flag was given.
2137 (syslog priority: Info)
2138 .RE
2139
2140 Only
2141 .B Fail,
2142 .B FailSpare,
2143 .B DegradedArray,
2144 .B SparesMissing
2145 and
2146 .B TestMessage
2147 cause Email to be sent. All events cause the program to be run.
2148 The program is run with two or three arguments: the event
2149 name, the array device and possibly a second device.
2150
2151 Each event has an associated array device (e.g.
2152 .BR /dev/md1 )
2153 and possibly a second device. For
2154 .BR Fail ,
2155 .BR FailSpare ,
2156 and
2157 .B SpareActive
2158 the second device is the relevant component device.
2159 For
2160 .B MoveSpare
2161 the second device is the array that the spare was moved from.
2162
2163 For
2164 .I mdadm
2165 to move spares from one array to another, the different arrays need to
2166 be labeled with the same
2167 .B spare-group
2168 or the spares must be allowed to migrate through matching POLICY domains
2169 in the configuration file. The
2170 .B spare-group
2171 name can be any string; it is only necessary that different spare
2172 groups use different names.
2173
2174 When
2175 .I mdadm
2176 detects that an array in a spare group has fewer active
2177 devices than necessary for the complete array, and has no spare
2178 devices, it will look for another array in the same spare group that
2179 has a full complement of working drive and a spare. It will then
2180 attempt to remove the spare from the second drive and add it to the
2181 first.
2182 If the removal succeeds but the adding fails, then it is added back to
2183 the original array.
2184
2185 If the spare group for a degraded array is not defined,
2186 .I mdadm
2187 will look at the rules of spare migration specified by POLICY lines in
2188 .B mdadm.conf
2189 and then follow similar steps as above if a matching spare is found.
2190
2191 .SH GROW MODE
2192 The GROW mode is used for changing the size or shape of an active
2193 array.
2194 For this to work, the kernel must support the necessary change.
2195 Various types of growth are being added during 2.6 development.
2196
2197 Currently the supported changes include
2198 .IP \(bu 4
2199 change the "size" attribute for RAID1, RAID4, RAID5 and RAID6.
2200 .IP \(bu 4
2201 increase or decrease the "raid\-devices" attribute of RAID0, RAID1, RAID4,
2202 RAID5, and RAID6.
2203 .IP \bu 4
2204 change the chunk-size and layout of RAID0, RAID4, RAID5 and RAID6.
2205 .IP \bu 4
2206 convert between RAID1 and RAID5, between RAID5 and RAID6, between
2207 RAID0, RAID5, and RAID5, and between RAID0 and RAID10 (in the near-2 mode).
2208 .IP \(bu 4
2209 add a write-intent bitmap to any array which supports these bitmaps, or
2210 remove a write-intent bitmap from such an array.
2211 .PP
2212
2213 Using GROW on containers is currently only support for Intel's IMSM
2214 container format. The number of devices in a container can be
2215 increased - which affects all arrays in the container - or an array
2216 in a container can be converted between levels where those levels are
2217 supported by the container, and the conversion is on of those listed
2218 above.
2219
2220 Grow functionality (e.g. expand a number of raid devices) for Intel's
2221 IMSM container format has an experimental status. It is guarded by the
2222 .B MDADM_EXPERIMENTAL
2223 environment variable which must be set to '1' for a GROW command to
2224 succeed.
2225 This is for the following reasons:
2226
2227 .IP 1.
2228 Intel's native IMSM check-pointing is not fully implemented yet.
2229 This causes IMSM incompatibility during the grow process: an array
2230 which is growing cannot roam between Microsoft Windows(R) and Linux
2231 systems.
2232
2233 .IP 2.
2234 Interrupting a grow operation is not recommended, because it
2235 has not been fully tested for Intel's IMSM container format yet.
2236
2237 .SS SIZE CHANGES
2238 Normally when an array is built the "size" is taken from the smallest
2239 of the drives. If all the small drives in an arrays are, one at a
2240 time, removed and replaced with larger drives, then you could have an
2241 array of large drives with only a small amount used. In this
2242 situation, changing the "size" with "GROW" mode will allow the extra
2243 space to start being used. If the size is increased in this way, a
2244 "resync" process will start to make sure the new parts of the array
2245 are synchronised.
2246
2247 Note that when an array changes size, any filesystem that may be
2248 stored in the array will not automatically grow for shrink to use or
2249 vacate the space. The
2250 filesystem will need to be explicitly told to use the extra space
2251 after growing, or to reduce its size
2252 .B prior
2253 to shrinking the array.
2254
2255 Also the size of an array cannot be changed while it has an active
2256 bitmap. If an array has a bitmap, it must be removed before the size
2257 can be changed. Once the change it complete a new bitmap can be created.
2258
2259 .SS RAID\-DEVICES CHANGES
2260
2261 A RAID1 array can work with any number of devices from 1 upwards
2262 (though 1 is not very useful). There may be times which you want to
2263 increase or decrease the number of active devices. Note that this is
2264 different to hot-add or hot-remove which changes the number of
2265 inactive devices.
2266
2267 When reducing the number of devices in a RAID1 array, the slots which
2268 are to be removed from the array must already be vacant. That is, the
2269 devices which were in those slots must be failed and removed.
2270
2271 When the number of devices is increased, any hot spares that are
2272 present will be activated immediately.
2273
2274 Changing the number of active devices in a RAID5 or RAID6 is much more
2275 effort. Every block in the array will need to be read and written
2276 back to a new location. From 2.6.17, the Linux Kernel is able to
2277 increase the number of devices in a RAID5 safely, including restarting
2278 an interrupted "reshape". From 2.6.31, the Linux Kernel is able to
2279 increase or decrease the number of devices in a RAID5 or RAID6.
2280
2281 From 2.6.35, the Linux Kernel is able to convert a RAID0 in to a RAID4
2282 or RAID5.
2283 .I mdadm
2284 uses this functionality and the ability to add
2285 devices to a RAID4 to allow devices to be added to a RAID0. When
2286 requested to do this,
2287 .I mdadm
2288 will convert the RAID0 to a RAID4, add the necessary disks and make
2289 the reshape happen, and then convert the RAID4 back to RAID0.
2290
2291 When decreasing the number of devices, the size of the array will also
2292 decrease. If there was data in the array, it could get destroyed and
2293 this is not reversible, so you should firstly shrink the filesystem on
2294 the array to fit within the new size. To help prevent accidents,
2295 .I mdadm
2296 requires that the size of the array be decreased first with
2297 .BR "mdadm --grow --array-size" .
2298 This is a reversible change which simply makes the end of the array
2299 inaccessible. The integrity of any data can then be checked before
2300 the non-reversible reduction in the number of devices is request.
2301
2302 When relocating the first few stripes on a RAID5 or RAID6, it is not
2303 possible to keep the data on disk completely consistent and
2304 crash-proof. To provide the required safety, mdadm disables writes to
2305 the array while this "critical section" is reshaped, and takes a
2306 backup of the data that is in that section. For grows, this backup may be
2307 stored in any spare devices that the array has, however it can also be
2308 stored in a separate file specified with the
2309 .B \-\-backup\-file
2310 option, and is required to be specified for shrinks, RAID level
2311 changes and layout changes. If this option is used, and the system
2312 does crash during the critical period, the same file must be passed to
2313 .B \-\-assemble
2314 to restore the backup and reassemble the array. When shrinking rather
2315 than growing the array, the reshape is done from the end towards the
2316 beginning, so the "critical section" is at the end of the reshape.
2317
2318 .SS LEVEL CHANGES
2319
2320 Changing the RAID level of any array happens instantaneously. However
2321 in the RAID5 to RAID6 case this requires a non-standard layout of the
2322 RAID6 data, and in the RAID6 to RAID5 case that non-standard layout is
2323 required before the change can be accomplished. So while the level
2324 change is instant, the accompanying layout change can take quite a
2325 long time. A
2326 .B \-\-backup\-file
2327 is required. If the array is not simultaneously being grown or
2328 shrunk, so that the array size will remain the same - for example,
2329 reshaping a 3-drive RAID5 into a 4-drive RAID6 - the backup file will
2330 be used not just for a "cricital section" but throughout the reshape
2331 operation, as described below under LAYOUT CHANGES.
2332
2333 .SS CHUNK-SIZE AND LAYOUT CHANGES
2334
2335 Changing the chunk-size of layout without also changing the number of
2336 devices as the same time will involve re-writing all blocks in-place.
2337 To ensure against data loss in the case of a crash, a
2338 .B --backup-file
2339 must be provided for these changes. Small sections of the array will
2340 be copied to the backup file while they are being rearranged. This
2341 means that all the data is copied twice, once to the backup and once
2342 to the new layout on the array, so this type of reshape will go very
2343 slowly.
2344
2345 If the reshape is interrupted for any reason, this backup file must be
2346 made available to
2347 .B "mdadm --assemble"
2348 so the array can be reassembled. Consequently the file cannot be
2349 stored on the device being reshaped.
2350
2351
2352 .SS BITMAP CHANGES
2353
2354 A write-intent bitmap can be added to, or removed from, an active
2355 array. Either internal bitmaps, or bitmaps stored in a separate file,
2356 can be added. Note that if you add a bitmap stored in a file which is
2357 in a filesystem that is on the RAID array being affected, the system
2358 will deadlock. The bitmap must be on a separate filesystem.
2359
2360 .SH INCREMENTAL MODE
2361
2362 .HP 12
2363 Usage:
2364 .B mdadm \-\-incremental
2365 .RB [ \-\-run ]
2366 .RB [ \-\-quiet ]
2367 .I component-device
2368 .HP 12
2369 Usage:
2370 .B mdadm \-\-incremental \-\-fail
2371 .I component-device
2372 .HP 12
2373 Usage:
2374 .B mdadm \-\-incremental \-\-rebuild\-map
2375 .HP 12
2376 Usage:
2377 .B mdadm \-\-incremental \-\-run \-\-scan
2378
2379 .PP
2380 This mode is designed to be used in conjunction with a device
2381 discovery system. As devices are found in a system, they can be
2382 passed to
2383 .B "mdadm \-\-incremental"
2384 to be conditionally added to an appropriate array.
2385
2386 Conversely, it can also be used with the
2387 .B \-\-fail
2388 flag to do just the opposite and find whatever array a particular device
2389 is part of and remove the device from that array.
2390
2391 If the device passed is a
2392 .B CONTAINER
2393 device created by a previous call to
2394 .IR mdadm ,
2395 then rather than trying to add that device to an array, all the arrays
2396 described by the metadata of the container will be started.
2397
2398 .I mdadm
2399 performs a number of tests to determine if the device is part of an
2400 array, and which array it should be part of. If an appropriate array
2401 is found, or can be created,
2402 .I mdadm
2403 adds the device to the array and conditionally starts the array.
2404
2405 Note that
2406 .I mdadm
2407 will normally only add devices to an array which were previously working
2408 (active or spare) parts of that array. The support for automatic
2409 inclusion of a new drive as a spare in some array requires
2410 a configuration through POLICY in config file.
2411
2412 The tests that
2413 .I mdadm
2414 makes are as follow:
2415 .IP +
2416 Is the device permitted by
2417 .BR mdadm.conf ?
2418 That is, is it listed in a
2419 .B DEVICES
2420 line in that file. If
2421 .B DEVICES
2422 is absent then the default it to allow any device. Similar if
2423 .B DEVICES
2424 contains the special word
2425 .B partitions
2426 then any device is allowed. Otherwise the device name given to
2427 .I mdadm
2428 must match one of the names or patterns in a
2429 .B DEVICES
2430 line.
2431
2432 .IP +
2433 Does the device have a valid md superblock. If a specific metadata
2434 version is request with
2435 .B \-\-metadata
2436 or
2437 .B \-e
2438 then only that style of metadata is accepted, otherwise
2439 .I mdadm
2440 finds any known version of metadata. If no
2441 .I md
2442 metadata is found, the device may be still added to an array
2443 as a spare if POLICY allows.
2444
2445 .ig
2446 .IP +
2447 Does the metadata match an expected array?
2448 The metadata can match in two ways. Either there is an array listed
2449 in
2450 .B mdadm.conf
2451 which identifies the array (either by UUID, by name, by device list,
2452 or by minor-number), or the array was created with a
2453 .B homehost
2454 specified and that
2455 .B homehost
2456 matches the one in
2457 .B mdadm.conf
2458 or on the command line.
2459 If
2460 .I mdadm
2461 is not able to positively identify the array as belonging to the
2462 current host, the device will be rejected.
2463 ..
2464
2465 .I mdadm
2466 keeps a list of arrays that it has partially assembled in
2467 .B /var/run/mdadm/map
2468 (or
2469 .B /var/run/mdadm.map
2470 if the directory doesn't exist. Or maybe even
2471 .BR /dev/.mdadm.map ).
2472 If no array exists which matches
2473 the metadata on the new device,
2474 .I mdadm
2475 must choose a device name and unit number. It does this based on any
2476 name given in
2477 .B mdadm.conf
2478 or any name information stored in the metadata. If this name
2479 suggests a unit number, that number will be used, otherwise a free
2480 unit number will be chosen. Normally
2481 .I mdadm
2482 will prefer to create a partitionable array, however if the
2483 .B CREATE
2484 line in
2485 .B mdadm.conf
2486 suggests that a non-partitionable array is preferred, that will be
2487 honoured.
2488
2489 If the array is not found in the config file and its metadata does not
2490 identify it as belonging to the "homehost", then
2491 .I mdadm
2492 will choose a name for the array which is certain not to conflict with
2493 any array which does belong to this host. It does this be adding an
2494 underscore and a small number to the name preferred by the metadata.
2495
2496 Once an appropriate array is found or created and the device is added,
2497 .I mdadm
2498 must decide if the array is ready to be started. It will
2499 normally compare the number of available (non-spare) devices to the
2500 number of devices that the metadata suggests need to be active. If
2501 there are at least that many, the array will be started. This means
2502 that if any devices are missing the array will not be restarted.
2503
2504 As an alternative,
2505 .B \-\-run
2506 may be passed to
2507 .I mdadm
2508 in which case the array will be run as soon as there are enough
2509 devices present for the data to be accessible. For a RAID1, that
2510 means one device will start the array. For a clean RAID5, the array
2511 will be started as soon as all but one drive is present.
2512
2513 Note that neither of these approaches is really ideal. If it can
2514 be known that all device discovery has completed, then
2515 .br
2516 .B " mdadm \-IRs"
2517 .br
2518 can be run which will try to start all arrays that are being
2519 incrementally assembled. They are started in "read-auto" mode in
2520 which they are read-only until the first write request. This means
2521 that no metadata updates are made and no attempt at resync or recovery
2522 happens. Further devices that are found before the first write can
2523 still be added safely.
2524
2525 .SH ENVIRONMENT
2526 This section describes environment variables that affect how mdadm
2527 operates.
2528
2529 .TP
2530 .B MDADM_NO_MDMON
2531 Setting this value to 1 will prevent mdadm from automatically launching
2532 mdmon. This variable is intended primarily for debugging mdadm/mdmon.
2533
2534 .TP
2535 .B MDADM_NO_UDEV
2536 Normally,
2537 .I mdadm
2538 does not create any device nodes in /dev, but leaves that task to
2539 .IR udev .
2540 If
2541 .I udev
2542 appears not to be configured, or if this environment variable is set
2543 to '1', the
2544 .I mdadm
2545 will create and devices that are needed.
2546
2547 .SH EXAMPLES
2548
2549 .B " mdadm \-\-query /dev/name-of-device"
2550 .br
2551 This will find out if a given device is a RAID array, or is part of
2552 one, and will provide brief information about the device.
2553
2554 .B " mdadm \-\-assemble \-\-scan"
2555 .br
2556 This will assemble and start all arrays listed in the standard config
2557 file. This command will typically go in a system startup file.
2558
2559 .B " mdadm \-\-stop \-\-scan"
2560 .br
2561 This will shut down all arrays that can be shut down (i.e. are not
2562 currently in use). This will typically go in a system shutdown script.
2563
2564 .B " mdadm \-\-follow \-\-scan \-\-delay=120"
2565 .br
2566 If (and only if) there is an Email address or program given in the
2567 standard config file, then
2568 monitor the status of all arrays listed in that file by
2569 polling them ever 2 minutes.
2570
2571 .B " mdadm \-\-create /dev/md0 \-\-level=1 \-\-raid\-devices=2 /dev/hd[ac]1"
2572 .br
2573 Create /dev/md0 as a RAID1 array consisting of /dev/hda1 and /dev/hdc1.
2574
2575 .br
2576 .B " echo 'DEVICE /dev/hd*[0\-9] /dev/sd*[0\-9]' > mdadm.conf"
2577 .br
2578 .B " mdadm \-\-detail \-\-scan >> mdadm.conf"
2579 .br
2580 This will create a prototype config file that describes currently
2581 active arrays that are known to be made from partitions of IDE or SCSI drives.
2582 This file should be reviewed before being used as it may
2583 contain unwanted detail.
2584
2585 .B " echo 'DEVICE /dev/hd[a\-z] /dev/sd*[a\-z]' > mdadm.conf"
2586 .br
2587 .B " mdadm \-\-examine \-\-scan \-\-config=mdadm.conf >> mdadm.conf"
2588 .br
2589 This will find arrays which could be assembled from existing IDE and
2590 SCSI whole drives (not partitions), and store the information in the
2591 format of a config file.
2592 This file is very likely to contain unwanted detail, particularly
2593 the
2594 .B devices=
2595 entries. It should be reviewed and edited before being used as an
2596 actual config file.
2597
2598 .B " mdadm \-\-examine \-\-brief \-\-scan \-\-config=partitions"
2599 .br
2600 .B " mdadm \-Ebsc partitions"
2601 .br
2602 Create a list of devices by reading
2603 .BR /proc/partitions ,
2604 scan these for RAID superblocks, and printout a brief listing of all
2605 that were found.
2606
2607 .B " mdadm \-Ac partitions \-m 0 /dev/md0"
2608 .br
2609 Scan all partitions and devices listed in
2610 .BR /proc/partitions
2611 and assemble
2612 .B /dev/md0
2613 out of all such devices with a RAID superblock with a minor number of 0.
2614
2615 .B " mdadm \-\-monitor \-\-scan \-\-daemonise > /var/run/mdadm"
2616 .br
2617 If config file contains a mail address or alert program, run mdadm in
2618 the background in monitor mode monitoring all md devices. Also write
2619 pid of mdadm daemon to
2620 .BR /var/run/mdadm .
2621
2622 .B " mdadm \-Iq /dev/somedevice"
2623 .br
2624 Try to incorporate newly discovered device into some array as
2625 appropriate.
2626
2627 .B " mdadm \-\-incremental \-\-rebuild\-map \-\-run \-\-scan"
2628 .br
2629 Rebuild the array map from any current arrays, and then start any that
2630 can be started.
2631
2632 .B " mdadm /dev/md4 --fail detached --remove detached"
2633 .br
2634 Any devices which are components of /dev/md4 will be marked as faulty
2635 and then remove from the array.
2636
2637 .B " mdadm --grow /dev/md4 --level=6 --backup-file=/root/backup-md4
2638 .br
2639 The array
2640 .B /dev/md4
2641 which is currently a RAID5 array will be converted to RAID6. There
2642 should normally already be a spare drive attached to the array as a
2643 RAID6 needs one more drive than a matching RAID5.
2644
2645 .B " mdadm --create /dev/md/ddf --metadata=ddf --raid-disks 6 /dev/sd[a-f]"
2646 .br
2647 Create a DDF array over 6 devices.
2648
2649 .B " mdadm --create /dev/md/home -n3 -l5 -z 30000000 /dev/md/ddf"
2650 .br
2651 Create a RAID5 array over any 3 devices in the given DDF set. Use
2652 only 30 gigabytes of each device.
2653
2654 .B " mdadm -A /dev/md/ddf1 /dev/sd[a-f]"
2655 .br
2656 Assemble a pre-exist ddf array.
2657
2658 .B " mdadm -I /dev/md/ddf1"
2659 .br
2660 Assemble all arrays contained in the ddf array, assigning names as
2661 appropriate.
2662
2663 .B " mdadm \-\-create \-\-help"
2664 .br
2665 Provide help about the Create mode.
2666
2667 .B " mdadm \-\-config \-\-help"
2668 .br
2669 Provide help about the format of the config file.
2670
2671 .B " mdadm \-\-help"
2672 .br
2673 Provide general help.
2674
2675 .SH FILES
2676
2677 .SS /proc/mdstat
2678
2679 If you're using the
2680 .B /proc
2681 filesystem,
2682 .B /proc/mdstat
2683 lists all active md devices with information about them.
2684 .I mdadm
2685 uses this to find arrays when
2686 .B \-\-scan
2687 is given in Misc mode, and to monitor array reconstruction
2688 on Monitor mode.
2689
2690 .SS /etc/mdadm.conf
2691
2692 The config file lists which devices may be scanned to see if
2693 they contain MD super block, and gives identifying information
2694 (e.g. UUID) about known MD arrays. See
2695 .BR mdadm.conf (5)
2696 for more details.
2697
2698 .SS /var/run/mdadm/map
2699 When
2700 .B \-\-incremental
2701 mode is used, this file gets a list of arrays currently being created.
2702 If
2703 .B /var/run/mdadm
2704 does not exist as a directory, then
2705 .B /var/run/mdadm.map
2706 is used instead. If
2707 .B /var/run
2708 is not available (as may be the case during early boot),
2709 .B /dev/.mdadm.map
2710 is used on the basis that
2711 .B /dev
2712 is usually available very early in boot.
2713
2714 .SH DEVICE NAMES
2715
2716 .I mdadm
2717 understand two sorts of names for array devices.
2718
2719 The first is the so-called 'standard' format name, which matches the
2720 names used by the kernel and which appear in
2721 .IR /proc/mdstat .
2722
2723 The second sort can be freely chosen, but must reside in
2724 .IR /dev/md/ .
2725 When giving a device name to
2726 .I mdadm
2727 to create or assemble an array, either full path name such as
2728 .I /dev/md0
2729 or
2730 .I /dev/md/home
2731 can be given, or just the suffix of the second sort of name, such as
2732 .I home
2733 can be given.
2734
2735 When
2736 .I mdadm
2737 chooses device names during auto-assembly or incremental assembly, it
2738 will sometimes add a small sequence number to the end of the name to
2739 avoid conflicted between multiple arrays that have the same name. If
2740 .I mdadm
2741 can reasonably determine that the array really is meant for this host,
2742 either by a hostname in the metadata, or by the presence of the array
2743 in
2744 .BR mdadm.conf ,
2745 then it will leave off the suffix if possible.
2746 Also if the homehost is specified as
2747 .B <ignore>
2748 .I mdadm
2749 will only use a suffix if a different array of the same name already
2750 exists or is listed in the config file.
2751
2752 The standard names for non-partitioned arrays (the only sort of md
2753 array available in 2.4 and earlier) are of the form
2754 .IP
2755 /dev/mdNN
2756 .PP
2757 where NN is a number.
2758 The standard names for partitionable arrays (as available from 2.6
2759 onwards) are of the form
2760 .IP
2761 /dev/md_dNN
2762 .PP
2763 Partition numbers should be indicated by added "pMM" to these, thus "/dev/md/d1p2".
2764 .PP
2765 From kernel version, 2.6.28 the "non-partitioned array" can actually
2766 be partitioned. So the "md_dNN" names are no longer needed, and
2767 partitions such as "/dev/mdNNpXX" are possible.
2768
2769 .SH NOTE
2770 .I mdadm
2771 was previously known as
2772 .IR mdctl .
2773 .P
2774 .I mdadm
2775 is completely separate from the
2776 .I raidtools
2777 package, and does not use the
2778 .I /etc/raidtab
2779 configuration file at all.
2780
2781 .SH SEE ALSO
2782 For further information on mdadm usage, MD and the various levels of
2783 RAID, see:
2784 .IP
2785 .B http://linux\-raid.osdl.org/
2786 .PP
2787 (based upon Jakob \(/Ostergaard's Software\-RAID.HOWTO)
2788 .\".PP
2789 .\"for new releases of the RAID driver check out:
2790 .\"
2791 .\".IP
2792 .\".UR ftp://ftp.kernel.org/pub/linux/kernel/people/mingo/raid-patches
2793 .\"ftp://ftp.kernel.org/pub/linux/kernel/people/mingo/raid-patches
2794 .\".UE
2795 .\".PP
2796 .\"or
2797 .\".IP
2798 .\".UR http://www.cse.unsw.edu.au/~neilb/patches/linux-stable/
2799 .\"http://www.cse.unsw.edu.au/~neilb/patches/linux-stable/
2800 .\".UE
2801 .PP
2802 The latest version of
2803 .I mdadm
2804 should always be available from
2805 .IP
2806 .B http://www.kernel.org/pub/linux/utils/raid/mdadm/
2807 .PP
2808 Related man pages:
2809 .PP
2810 .IR mdmon (8),
2811 .IR mdadm.conf (5),
2812 .IR md (4).
2813 .PP
2814 .IR raidtab (5),
2815 .IR raid0run (8),
2816 .IR raidstop (8),
2817 .IR mkraid (8).