]> git.ipfire.org Git - thirdparty/systemd.git/blobdiff - man/sd_bus_default.xml
sd-event: define a new PREPARING state
[thirdparty/systemd.git] / man / sd_bus_default.xml
index 55f1b8bb6906b8b55a2335fe917b1e10c1769188..6d5a90de72fa2c27756dbc5273db31813f23a5ee 100644 (file)
@@ -1,9 +1,6 @@
 <?xml version='1.0'?> <!--*- Mode: nxml; nxml-child-indent: 2; indent-tabs-mode: nil -*-->
 <!DOCTYPE refentry PUBLIC "-//OASIS//DTD DocBook XML V4.2//EN"
-"http://www.oasis-open.org/docbook/xml/4.2/docbookx.dtd" [
-<!ENTITY % entities SYSTEM "custom-entities.ent" >
-%entities;
-]>
+"http://www.oasis-open.org/docbook/xml/4.2/docbookx.dtd">
 
 <!--
   This file is part of systemd.
@@ -24,7 +21,7 @@
   along with systemd; If not, see <http://www.gnu.org/licenses/>.
 -->
 
-<refentry id="sd_bus_default" conditional="ENABLE_KDBUS">
+<refentry id="sd_bus_default">
 
   <refentryinfo>
     <title>sd_bus_default</title>
     <title>Description</title>
 
     <para><function>sd_bus_default()</function> acquires a bus
-    connection object to the user bus when invoked in user context or
+    connection object to the user bus when invoked in user context, or
     to the system bus otherwise. The connection object is associated
-    to the calling thread. Each time the function is invoked from the
-    same thread the same object is returned, but its reference count
-    increased by one, as long as at least one reference is kept. When
-    the last reference to the connection is dropped (using the
-    <function>sd_bus_unref()</function> call), the connection is
-    terminated. Note that the connection is not automatically
-    terminated when the associated thread ends. It is important to
-    drop the last reference to the bus connection explicitly before
-    the thread ends or otherwise the connection will be leaked.</para>
+    with the calling thread. Each time the function is invoked from
+    the same thread, the same object is returned, but its reference
+    count is increased by one, as long as at least one reference is
+    kept. When the last reference to the connection is dropped (using
+    the
+    <citerefentry><refentrytitle>sd_bus_unref</refentrytitle><manvolnum>3</manvolnum></citerefentry>
+    call), the connection is terminated. Note that the connection is
+    not automatically terminated when the associated thread ends. It
+    is important to drop the last reference to the bus connection
+    explicitly before the thread ends, as otherwise, the connection will
+    leak. Also, queued but unread or unwritten messages keep the
+    bus referenced, see below.</para>
 
     <para><function>sd_bus_default_user()</function> returns a user
-    bus connection object associated to the calling thread.
+    bus connection object associated with the calling thread.
     <function>sd_bus_default_system()</function> is similar, but
-    connects to the system bus.</para>
+    connects to the system bus. Note that
+    <function>sd_bus_default()</function> is identical to these two
+    calls, depending on the execution context.</para>
 
     <para><function>sd_bus_open()</function> creates a new,
     independent bus connection to the user bus when invoked in user
-    context or the system bus
+    context, or the system bus
     otherwise. <function>sd_bus_open_user()</function> is similar, but
     connects only to the user bus.
     <function>sd_bus_open_system()</function> does the same, but
     connects to the system bus. In contrast to
     <function>sd_bus_default()</function>,
-    <function>sd_bus_default_user()</function>,
-    <function>sd_bus_default_system()</function> these calls return
+    <function>sd_bus_default_user()</function>, and
+    <function>sd_bus_default_system()</function>, these calls return
     new, independent connection objects that are not associated with
     the invoking thread and are not shared between multiple
     invocations. It is recommended to share connections per thread to
     efficiently make use the available resources. Thus, it is
     recommended to use <function>sd_bus_default()</function>,
-    <function>sd_bus_default_user()</function>,
+    <function>sd_bus_default_user()</function> and
     <function>sd_bus_default_system()</function> to connect to the
     user or system buses.</para>
 
 
     <para><function>sd_bus_open_system_remote()</function> connects to
     the system bus on the specified <parameter>host</parameter> using
-    SSH. <parameter>host</parameter> consists of an optional user name
-    followed by the <literal>@</literal> symbol, and the hostname.
+    <citerefentry
+    project='die-net'><refentrytitle>ssh</refentrytitle><manvolnum>1</manvolnum></citerefentry>. <parameter>host</parameter>
+    consists of an optional user name followed by the
+    <literal>@</literal> symbol, and the hostname.
     </para>
 
-    <para><function>sd_bus_open_system_container()</function> connects
+    <para><function>sd_bus_open_system_machine()</function> connects
     to the system bus in the specified <parameter>machine</parameter>,
     where <parameter>machine</parameter> is the name of a local
     container.  See
     <citerefentry><refentrytitle>machinectl</refentrytitle><manvolnum>1</manvolnum></citerefentry>
-    for more information about "machines".</para>
-
-  </refsect1>
-
-  <refsect1>
-    <title>Return Value</title>
+    for more information about the "machine" concept. Note that
+    connections into local containers are only available to privileged
+    processes at this time.</para>
+
+    <para>These calls allocate a bus connection object and initiate
+    the connection to a well-known bus of some form. An alternative to
+    using these high-level calls is to create an unconnected bus
+    object with
+    <citerefentry><refentrytitle>sd_bus_new</refentrytitle><manvolnum>3</manvolnum></citerefentry>
+    and to connect it with
+    <citerefentry><refentrytitle>sd_bus_start</refentrytitle><manvolnum>3</manvolnum></citerefentry>.
+    </para>
 
-    <para>On success, these calls return 0 or a positive
-    integer. On failure, these calls return a negative
-    errno-style error code.</para>
   </refsect1>
 
   <refsect1>
     <title>Reference ownership</title>
-    <para>The functions <function>sd_bus_open_user()</function>,
-    <function>sd_bus_open()</function>,
+    <para>The functions <function>sd_bus_open()</function>,
+    <function>sd_bus_open_user()</function>,
     <function>sd_bus_open_system()</function>,
     <function>sd_bus_open_system_remote()</function>, and
     <function>sd_bus_open_system_machine()</function> return a new
-    object and the caller owns the sole reference. When not needed
-    anymore, this reference should be destroyed with
+    connection object and the caller owns the sole reference. When not
+    needed anymore, this reference should be destroyed with
     <citerefentry><refentrytitle>sd_bus_unref</refentrytitle><manvolnum>3</manvolnum></citerefentry>.
     </para>
 
     <para>The functions <function>sd_bus_default()</function>,
     <function>sd_bus_default_user()</function> and
     <function>sd_bus_default_system()</function> do not necessarily
-    create a new object, but increase the connection reference by
-    one. Use
+    create a new object, but increase the connection reference of an
+    existing connection object by one. Use
     <citerefentry><refentrytitle>sd_bus_unref</refentrytitle><manvolnum>3</manvolnum></citerefentry>
     to drop the reference.</para>
+
+    <para>Queued but unwritten/unread messages also keep a reference
+    to their bus connection object. For this reason, even if an
+    application dropped all references to a bus connection, it might
+    not get destroyed right away. Until all incoming queued
+    messages are read, and until all outgoing unwritten messages are
+    written, the bus object will stay
+    alive. <function>sd_bus_flush()</function> may be used to write
+    all outgoing queued messages so they drop their references. To
+    flush the unread incoming messages, use
+    <function>sd_bus_close()</function>, which will also close the bus
+    connection. When using the default bus logic, it is a good idea to
+    first invoke <function>sd_bus_flush()</function> followed by
+    <function>sd_bus_close()</function> when a thread or process
+    terminates, and thus its bus connection object should be
+    freed.</para>
+
+    <para>The life cycle of the default bus connection should be the
+    responsibility of the code that creates/owns the thread the
+    default bus connection object is associated with. Library code
+    should neither call <function>sd_bus_flush()</function> nor
+    <function>sd_bus_close()</function> on default bus objects unless
+    it does so in its own private, self-allocated thread. Library code
+    should not use the default bus object in other threads unless it
+    is clear that the program using it will life cycle the bus
+    connection object and flush and close it before exiting from the
+    thread. In libraries where it is not clear that the calling
+    program will life cycle the bus connection object, it is hence
+    recommended to use <function>sd_bus_open_system()</function>
+    instead of <function>sd_bus_default_system()</function> and
+    related calls.</para>
+  </refsect1>
+
+  <refsect1>
+    <title>Return Value</title>
+
+    <para>On success, these calls return 0 or a positive
+    integer. On failure, these calls return a negative
+    errno-style error code.</para>
   </refsect1>
 
   <refsect1>