]> git.ipfire.org Git - thirdparty/kernel/stable.git/commit
iio: pressure: mpl115: fix temperature offset sign
authorAkinobu Mita <akinobu.mita@gmail.com>
Wed, 20 Jan 2016 16:07:31 +0000 (01:07 +0900)
committerSasha Levin <sasha.levin@oracle.com>
Tue, 12 Apr 2016 02:07:36 +0000 (22:07 -0400)
commit17fe8c8b306e4b76078b8b103e1f344970409378
tree7dd51315dbfe402f2950913e7a245516a26fa486
parent5b20b25abab6faba0c91a4d7ccde93e134f29d6d
iio: pressure: mpl115: fix temperature offset sign

[ Upstream commit 431386e783a3a6c8b7707bee32d18c353b8688b2 ]

According to the datasheet, the resolusion of temperature sensor is
-5.35 counts/C. Temperature ADC is 472 counts at 25C.
(https://www.sparkfun.com/datasheets/Sensors/Pressure/MPL115A1.pdf
NOTE: This is older revision, but this information is removed from the
latest datasheet from nxp somehow)

Temp [C] = (Tadc - 472) / -5.35 + 25
         = (Tadc - 605.750000) * -0.186915888

So the correct offset is -605.750000.

Signed-off-by: Akinobu Mita <akinobu.mita@gmail.com>
Acked-by: Peter Meerwald-Stadler <pmeerw@pmeerw.net>
Cc: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
Signed-off-by: Sasha Levin <sasha.levin@oracle.com>
drivers/iio/pressure/mpl115.c