comedi: rti802: Add sanity checks for I/O base address
The "rti800" driver uses an admin-supplied configuration option
(`it->options[0]`) to configure the I/O port base address of a RTI-802
board. It currently allows any base address to be configured but the
hardware only supports base addresses (configured by on-board DIP
switches) in the range 0 to 0x3FC on 4-byte boundaries.
Add a sanity check to ensure the device is not configured at an
unsupported base address.
Signed-off-by: Ian Abbott <abbotti@mev.co.uk>
Link: https://patch.msgid.link/20260130170416.49994-46-abbotti@mev.co.uk
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>