git.ipfire.org Git - thirdparty/kernel/linux.git/commit
iio: pressure: mprls0025pa: fix pressure calculation
A sign change is needed for proper calculation of the pressure.
This is a minor fix since it only affects users that might have custom
silicon from Honeywell that has honeywell,pmin-pascal != 0.
Also due to the fact that raw pressure values can not be lower
than output_min (400k-3.3M) there is no need to calculate a decimal for
the offset.
Fixes: 713337d9143e ("iio: pressure: Honeywell mprls0025pa pressure sensor")
Signed-off-by: Petre Rodan <petre.rodan@subdimension.ro>
Reviewed-by: Andy Shevchenko <andriy.shevchenko@intel.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>