Merged revisions 250480 via svnmerge from
https://origsvn.digium.com/svn/asterisk/branches/1.4
........
r250480 | jpeeler | 2010-03-03 13:04:11 -0600 (Wed, 03 Mar 2010) | 15 lines
Make sure to clear red alarm after polarity reversal.
From the issue:
The automatic overnight line tests (or manual ones) used on UK (BT) lines causes
a red alarm on a dahdi / TDM400P connected channel. This is because the line
uses voltage tests (battery loss) and polarity reversal. The polarity reversal
causes chan_dahdi to initiate v23 CallerID processing but during this the event
DAHDI_EVENT_NOALARM is ignored so that the alarm is never cleared.
(closes issue #14163)
Reported by: jedi98
Patches:
chan_dahdi-1.4-inalarm.diff uploaded by jedi98 (license 653)
Tested by: mattbrown, Chainsaw, mikeeccleston
........
git-svn-id: https://origsvn.digium.com/svn/asterisk/trunk@250481
65c4cc65-6c06-0410-ace0-
fbb531ad65f3