firmware: arm_scmi: Read sensor config as 32-bit value
The SENSOR_CONFIG_GET response contains a 32-bit sensor_config field,
and the xfer is initialized with a 4-byte RX buffer. Reading it with
get_unaligned_le64() can consume bytes past the returned payload.
Use get_unaligned_le32() to match the protocol layout and the allocated
response size.
Fixes: 7b83c5f41088 ("firmware: arm_scmi: Add SCMI v3.0 sensor configuration support")
Link: https://patch.msgid.link/20260517-scmi_fixes-v1-1-d86daec4defd@kernel.org
Reviewed-by: Cristian Marussi <cristian.marussi@arm.com>
Signed-off-by: Sudeep Holla <sudeep.holla@kernel.org>