* followed by a 3 second silent (2100 Hz OFF) period.
*/
#define FAX_TONE_CNG_FREQ 1100
-#define FAX_TONE_CNG_DURATION 500
+#define FAX_TONE_CNG_DURATION 500 /* ms */
#define FAX_TONE_CNG_DB 16
/* This signal may be sent by the Terminating FAX machine anywhere between
* of a 2100 Hz tone that is from 2.6 to 4 seconds in duration.
*/
#define FAX_TONE_CED_FREQ 2100
-#define FAX_TONE_CED_DURATION 2600
+#define FAX_TONE_CED_DURATION 2600 /* ms */
#define FAX_TONE_CED_DB 16
#define DEFAULT_SAMPLE_RATE 8000
}
if (s->hit_count == s->hits_required) {
- ast_debug(1, "%d Hz done detected\n", s->freq);
+ ast_debug(1, "%d Hz tone detected\n", s->freq);
res = 1;
}
for (x = 0; x < len; x++) {
odata[x] = AST_LIN2MU((unsigned short) shortdata[x]);
}
- } else if (ast_format_cmp(af->subclass.format, ast_format_ulaw) == AST_FORMAT_CMP_EQUAL) {
+ } else if (ast_format_cmp(af->subclass.format, ast_format_alaw) == AST_FORMAT_CMP_EQUAL) {
for (x = 0; x < len; x++) {
odata[x] = AST_LIN2A((unsigned short) shortdata[x]);
}