]> git.ipfire.org Git - thirdparty/chrony.git/commitdiff
doc: add new questions to FAQ
authorMiroslav Lichvar <mlichvar@redhat.com>
Mon, 21 May 2018 12:49:53 +0000 (14:49 +0200)
committerMiroslav Lichvar <mlichvar@redhat.com>
Fri, 25 May 2018 08:53:21 +0000 (10:53 +0200)
doc/faq.adoc

index 5bad34f3daa5b999533ff0ce04639a579c364298..95f02dd9550e4622e99a4fb663a83b99784b42c0 100644 (file)
@@ -292,6 +292,49 @@ to
 makestep 1 -1
 ----
 
+=== Using a Windows NTP server?
+
+A common issue with Windows NTP servers is that they report a very large root
+dispersion (e.g. three seconds or more), which causes `chronyd` to ignore the
+server for being too inaccurate. The `sources` command may show a valid
+measurement, but the server is not selected for synchronisation. You can check
+the root dispersion of the server with the ``chronyc``'s `ntpdata` command.
+
+The `maxdistance` value needs to be increased in _chrony.conf_ to enable
+synchronisation to such a server. For example:
+
+----
+maxdistance 16.0
+----
+
+=== Using a PPS reference clock?
+
+A pulse-per-second (PPS) reference clock requires a non-PPS time source to
+determine which second of UTC corresponds to each pulse. If it is another
+reference clock specified with the `lock` option in the `refclock` directive,
+the offset between the two reference clocks must be smaller than 0.2 seconds in
+order for the PPS reference clock to work. With NMEA reference clocks it is
+common to have a larger offset. It needs to be corrected with the `offset`
+option.
+
+One approach to find out a good value of the `offset` option is to configure
+the reference clocks with the `noselect` option and compare them to an NTP
+server. For example, if the `sourcestats` command showed
+
+----
+Name/IP Address            NP  NR  Span  Frequency  Freq Skew  Offset  Std Dev
+==============================================================================
+PPS0                        0   0     0     +0.000   2000.000     +0ns  4000ms
+NMEA                       58  30   231    -96.494     38.406   +504ms  6080us
+foo.example.net             7   3   200     -2.991     16.141   -107us   492us
+----
+
+the offset of the NMEA source would need to be increased by about 0.504
+seconds. It does not have to be very accurate. As long as the offset of the
+NMEA reference clock stays below 0.2 seconds, the PPS reference clock should be
+able to determine the seconds corresponding to the pulses and allow the samples
+to be used for synchronisation.
+
 == Issues with `chronyc`
 