--- /dev/null
+_cfdisk_module()
+{
+ local cur prev OPTS
+ COMPREPLY=()
+ cur="${COMP_WORDS[COMP_CWORD]}"
+ prev="${COMP_WORDS[COMP_CWORD-1]}"
+ case $prev in
+ '-c')
+ COMPREPLY=( $(compgen -W "cylinders" -- $cur) )
+ return 0
+ ;;
+ '-h')
+ COMPREPLY=( $(compgen -W "heads" -- $cur) )
+ return 0
+ ;;
+ '-s')
+ COMPREPLY=( $(compgen -W "sectors" -- $cur) )
+ return 0
+ ;;
+ esac
+ case $cur in
+ -*)
+ OPTS="-a -z -c -h -s"
+ COMPREPLY=( $(compgen -W "${OPTS[*]}" -- $cur) )
+ return 0
+ ;;
+ esac
+ local DEV TYPE DEVICES=''
+ while read DEV TYPE; do
+ [ $TYPE = 'disk' ] && DEVICES+="$DEV "
+ done < <(lsblk -pnro name,type)
+ COMPREPLY=( $(compgen -W "$DEVICES" -- $cur) )
+ return 0
+}
+complete -F _cfdisk_module cfdisk
--- /dev/null
+_fdisk_module()
+{
+ local cur prev OPTS
+ COMPREPLY=()
+ cur="${COMP_WORDS[COMP_CWORD]}"
+ prev="${COMP_WORDS[COMP_CWORD-1]}"
+ case $prev in
+ '-s')
+ local DEV TYPE DEVICES=''
+ while read DEV TYPE; do
+ [ $TYPE = 'part' ] && DEVICES+="$DEV "
+ done < <(lsblk -pnro name,type)
+ COMPREPLY=( $(compgen -W "$DEVICES" -- $cur) )
+ return 0
+ ;;
+ '-b')
+ COMPREPLY=( $(compgen -W "512 1024 2048 4096" -- $cur) )
+ return 0
+ ;;
+ '-c')
+ COMPREPLY=( $(compgen -W "dos nondos" -- $cur) )
+ return 0
+ ;;
+ '-u')
+ COMPREPLY=( $(compgen -W "cylinders sectors" -- $cur) )
+ return 0
+ ;;
+ '-C'|'-H'|'-S')
+ COMPREPLY=( $(compgen -W "number" -- $cur) )
+ return 0
+ ;;
+ esac
+ case $cur in
+ -*)
+ OPTS="-l -s -b -c -h -u -v -C -H -S"
+ COMPREPLY=( $(compgen -W "${OPTS[*]}" -- $cur) )
+ return 0
+ ;;
+ esac
+ local DEV TYPE DEVICES=''
+ while read DEV TYPE; do
+ [ $TYPE = 'disk' ] && DEVICES+="$DEV "
+ done < <(lsblk -pnro name,type)
+ COMPREPLY=( $(compgen -W "$DEVICES" -- $cur) )
+ return 0
+}
+complete -F _fdisk_module fdisk
--- /dev/null
+_sfdisk_module()
+{
+ local cur prev OPTS
+ COMPREPLY=()
+ cur="${COMP_WORDS[COMP_CWORD]}"
+ prev="${COMP_WORDS[COMP_CWORD-1]}"
+ case $prev in
+ '-u'|'--unit')
+ COMPREPLY=( $(compgen -W "S C B M" -- $cur) )
+ return 0
+ ;;
+ '-n'|'-C'|'--cylinders'|'-H'|'--heads'|'-S'|'--sectors')
+ COMPREPLY=( $(compgen -W "number" -- $cur) )
+ return 0
+ ;;
+ '-O'|'-I')
+ compopt -o filenames
+ COMPREPLY=( $(compgen -f -- $cur) )
+ return 0
+ ;;
+ esac
+ case $cur in
+ '=')
+ cur=${cur#=}
+ ;;
+ -*)
+ OPTS="-s --show-size
+ -c --id
+ --change-id
+ --print-id
+ -l --list
+ -d --dump
+ -i --increment
+ -u --unit
+ -1 --one-only
+ -T --list-types
+ -D --DOS
+ -E --DOS-extended
+ -R --re-read
+ -N
+ -n
+ -O
+ -I
+ -V --verify
+ -v --version
+ -h --help
+ -f --force
+ --no-reread
+ -q --quiet
+ -L --Linux
+ -g --show-geometry
+ -G --show-pt-geometry
+ -A= --activate=
+ -U= --unhide=
+ -x --show-extended
+ --leave-last
+ --IBM
+ --in-order
+ --not-in-order
+ --inside-outer
+ --not-inside-outer
+ --nested
+ --chained
+ --onesector
+ -C --cylinders
+ -H --heads
+ -S --sectors"
+ COMPREPLY=( $(compgen -W "${OPTS[*]}" -- $cur) )
+ return 0
+ ;;
+ esac
+ local DEV TYPE DEVICES=''
+ while read DEV TYPE; do
+ [ $TYPE = 'disk' ] && DEVICES+="$DEV "
+ done < <(lsblk -pnro name,type)
+ COMPREPLY=( $(compgen -W "$DEVICES" -- $cur) )
+ return 0
+}
+complete -F _sfdisk_module sfdisk