English: http://www.aosong.com/userfiles/files/media/Data%20Sheet%20AHT20.pdf
+ * Aosong DHT20
+
+ Prefix: 'dht20'
+
+ Addresses scanned: None
+
+ Datasheet: https://www.digikey.co.nz/en/htmldatasheets/production/9184855/0/0/1/101020932
+
Author: Johannes Cornelis Draaijer <jcdra1@gmail.com>
Special Features
----------------
-AHT20 has additional CRC8 support which is sent as the last byte of the sensor
+AHT20, DHT20 has additional CRC8 support which is sent as the last byte of the sensor
values.
Usage Notes
will be called adt7475.
config SENSORS_AHT10
- tristate "Aosong AHT10, AHT20"
+ tristate "Aosong AHT10, AHT20, DHT20"
depends on I2C
select CRC8
help
- If you say yes here, you get support for the Aosong AHT10 and AHT20
- temperature and humidity sensors
+ If you say yes here, you get support for the Aosong AHT10, AHT20 and
+ DHT20 temperature and humidity sensors
This driver can also be built as a module. If so, the module
will be called aht10.
#define AHT10_CMD_MEAS 0b10101100
#define AHT10_CMD_RST 0b10111010
+#define DHT20_CMD_INIT 0x71
+
/*
* Flags in the answer byte/command
*/
#define AHT10_MAX_POLL_INTERVAL_LEN 30
-enum aht10_variant { aht10, aht20 };
+enum aht10_variant { aht10, aht20, dht20};
static const struct i2c_device_id aht10_id[] = {
{ "aht10", aht10 },
{ "aht20", aht20 },
+ { "dht20", dht20 },
{ },
};
MODULE_DEVICE_TABLE(i2c, aht10_id);
* AHT10/AHT20
* @crc8: crc8 support flag
* @meas_size: measurements data size
+ * @init_cmd: Initialization command
*/
struct aht10_data {
int humidity;
bool crc8;
unsigned int meas_size;
+ u8 init_cmd;
};
/*
*/
static int aht10_init(struct aht10_data *data)
{
- const u8 cmd_init[] = {AHT10_CMD_INIT, AHT10_CAL_ENABLED | AHT10_MODE_CYC,
+ const u8 cmd_init[] = {data->init_cmd, AHT10_CAL_ENABLED | AHT10_MODE_CYC,
0x00};
int res;
u8 status;
struct i2c_client *client = data->client;
- res = i2c_master_send(client, cmd_init, 3);
+ res = i2c_master_send(client, cmd_init, sizeof(cmd_init));
if (res < 0)
return res;
data->meas_size = AHT20_MEAS_SIZE;
data->crc8 = true;
crc8_populate_msb(crc8_table, AHT20_CRC8_POLY);
+ data->init_cmd = AHT10_CMD_INIT;
+ break;
+ case dht20:
+ data->meas_size = AHT20_MEAS_SIZE;
+ data->crc8 = true;
+ crc8_populate_msb(crc8_table, AHT20_CRC8_POLY);
+ data->init_cmd = DHT20_CMD_INIT;
break;
default:
data->meas_size = AHT10_MEAS_SIZE;
+ data->init_cmd = AHT10_CMD_INIT;
break;
}