]> git.ipfire.org Git - thirdparty/kernel/stable.git/commitdiff
smb3.1.1: fix posix mounts to older servers
authorSteve French <stfrench@microsoft.com>
Wed, 4 Dec 2024 23:46:00 +0000 (17:46 -0600)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Sat, 14 Dec 2024 19:03:26 +0000 (20:03 +0100)
commit ddca5023091588eb303e3c0097d95c325992d05f upstream.

Some servers which implement the SMB3.1.1 POSIX extensions did not
set the file type in the mode in the infolevel 100 response.
With the recent changes for checking the file type via the mode field,
this can cause the root directory to be reported incorrectly and
mounts (e.g. to ksmbd) to fail.

Fixes: 6a832bc8bbb2 ("fs/smb/client: Implement new SMB3 POSIX type")
Cc: stable@vger.kernel.org
Acked-by: Paulo Alcantara (Red Hat) <pc@manguebit.com>
Cc: Ralph Boehme <slow@samba.org>
Signed-off-by: Steve French <stfrench@microsoft.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
fs/smb/client/cifsproto.h
fs/smb/client/inode.c
fs/smb/client/readdir.c

index 82c03877aac1ec91b98e170017c81f9c85cf360d..a697e53ccee2bee375f19a15fbb69158643c3141 100644 (file)
@@ -677,7 +677,7 @@ int __cifs_sfu_make_node(unsigned int xid, struct inode *inode,
 int cifs_sfu_make_node(unsigned int xid, struct inode *inode,
                       struct dentry *dentry, struct cifs_tcon *tcon,
                       const char *full_path, umode_t mode, dev_t dev);
-umode_t wire_mode_to_posix(u32 wire);
+umode_t wire_mode_to_posix(u32 wire, bool is_dir);
 
 #ifdef CONFIG_CIFS_DFS_UPCALL
 static inline int get_dfs_path(const unsigned int xid, struct cifs_ses *ses,
index a80206cff797951e33c1f2beaa402f308b5533c9..b35fe1075503e1b7b83eb770a422beb49b13e9f8 100644 (file)
@@ -792,13 +792,17 @@ static u32 wire_filetype_to_posix(u32 wire_type)
        return posix_filetypes[wire_type];
 }
 
-umode_t wire_mode_to_posix(u32 wire)
+umode_t wire_mode_to_posix(u32 wire, bool is_dir)
 {
        u32 wire_type;
        u32 mode;
 
        wire_type = (wire & POSIX_FILETYPE_MASK) >> POSIX_FILETYPE_SHIFT;
-       mode = (wire_perms_to_posix(wire) | wire_filetype_to_posix(wire_type));
+       /* older servers do not set POSIX file type in the mode field in the response */
+       if ((wire_type == 0) && is_dir)
+               mode = wire_perms_to_posix(wire) | S_IFDIR;
+       else
+               mode = (wire_perms_to_posix(wire) | wire_filetype_to_posix(wire_type));
        return (umode_t)mode;
 }
 
@@ -838,7 +842,8 @@ static void smb311_posix_info_to_fattr(struct cifs_fattr *fattr,
        fattr->cf_bytes = le64_to_cpu(info->AllocationSize);
        fattr->cf_createtime = le64_to_cpu(info->CreationTime);
        fattr->cf_nlink = le32_to_cpu(info->HardLinks);
-       fattr->cf_mode = wire_mode_to_posix(le32_to_cpu(info->Mode));
+       fattr->cf_mode = wire_mode_to_posix(le32_to_cpu(info->Mode),
+                                           fattr->cf_cifsattrs & ATTR_DIRECTORY);
 
        if (cifs_open_data_reparse(data) &&
            cifs_reparse_point_to_fattr(cifs_sb, fattr, data))
index b906bf78af1ecca81101b49f1c1939d2bbe513b1..273358d20a46c9b04b00fcd35e252c197d1926b2 100644 (file)
@@ -261,7 +261,8 @@ cifs_posix_to_fattr(struct cifs_fattr *fattr, struct smb2_posix_info *info,
                fattr->cf_cifstag = le32_to_cpu(info->ReparseTag);
 
        /* The Mode field in the response can now include the file type as well */
-       fattr->cf_mode = wire_mode_to_posix(le32_to_cpu(info->Mode));
+       fattr->cf_mode = wire_mode_to_posix(le32_to_cpu(info->Mode),
+                                           fattr->cf_cifsattrs & ATTR_DIRECTORY);
        fattr->cf_dtype = S_DT(le32_to_cpu(info->Mode));
 
        switch (fattr->cf_mode & S_IFMT) {