The SC13A ( VID 0x1ff7, PID 0x0f81) not support reading the current
sample rate and results in an error message printed to kmsg. Set
QUIRK_FLAG_GET_SAMPLE_RATE to skip the sample rate check.
Quirky device sample:
usb 3-5.2.4.1: new high-speed USB device number 11 using xhci_hcd
usb 3-5.2.4.1: New USB device found, idVendor=1ff7, idProduct=0f81
usb 3-5.2.4.1: New USB device strings: Mfr=1, Product=2, SerialNumber=3
usb 3-5.2.4.1: Product: SC13A
usb 3-5.2.4.1: Manufacturer: Linux Foundation
usb 3-5.2.4.1: SerialNumber: 000002
usb 3-5.2.4.1: Found UVC 1.50 device SC13A (1ff7:0f81)
usb 3-5.2.4.1: 3:1: cannot get freq at ep 0x86
usb 3-5.2.4.1: Warning! Unlikely big volume range (=4096),
cval->res is probably wrong.
usb 3-5.2.4.1: [5] FU [Mic Capture Volume] ch = 1, val = 0/4096/1
usbcore: registered new interface driver snd-usb-audio
usb 3-5.2.4.1: 3:1: cannot get freq at ep 0x86
usb 3-5.2.4.1: 3:1: cannot get freq at ep 0x86
Signed-off-by: Ai Chao <aichao@kylinos.cn>
Link: https://patch.msgid.link/20260617025234.3344935-1-aichao@kylinos.cn
Signed-off-by: Takashi Iwai <tiwai@suse.de>
QUIRK_FLAG_GET_SAMPLE_RATE | QUIRK_FLAG_MIC_RES_16),
DEVICE_FLG(0x1bcf, 0x2283, /* NexiGo N930AF FHD Webcam */
QUIRK_FLAG_GET_SAMPLE_RATE | QUIRK_FLAG_MIC_RES_16),
+ DEVICE_FLG(0x1ff7, 0x0f81, /* SC13A Webcam */
+ QUIRK_FLAG_GET_SAMPLE_RATE),
DEVICE_FLG(0x2040, 0x7200, /* Hauppauge HVR-950Q */
QUIRK_FLAG_SHARE_MEDIA_DEVICE | QUIRK_FLAG_ALIGN_TRANSFER),
DEVICE_FLG(0x2040, 0x7201, /* Hauppauge HVR-950Q-MXL */