+Modbus Keyword
+==============
+
+The modbus keyword can be used for matching on various properties of
+Modbus requests.
+
+There are two ways of using this keyword:
+
+* matching on functions properties with the setting "function";
+* matching on directly on data access with the setting "access".
+
+With the setting **function**, you can match on:
+
+* an action based on a function code field and a sub-function code when applicable;
+* one of three categories of Modbus functions;
+* public functions that are publicly defined (setting "public")
+* user-defined functions (setting "user")
+* reserved functions that are dedicated to proprietary extensions of Modbus (keyword "reserved")
+* one of the two sub-groups of public functions:
+
+ * assigned functions whose definition is already given in the Modbus specification (keyword "assigned");
+ * unassigned functions, which are reserved for future use (keyword "unassigned").
+
+Syntax::
+
+ modbus: function <value>
+ modbus: function <value>, subfunction <value>
+ modbus: function [!] <assigned | unassigned | public | user | reserved | all>
+
+Sign '!' is negation
+
+Examples::
+
+ modbus: function 21 # Write File record function
+ modbus: function 4, subfunction 4 # Force Listen Only Mode (Diagnostics) function
+ modbus: function assigned # defined by Modbus Application Protocol Specification V1.1b3
+ modbus: function public # validated by the Modbus.org community
+ modbus: function user # internal use and not supported by the specification
+ modbus: function reserved # used by some companies for legacy products and not available for public use
+ modbus: function !reserved # every function but reserved function
+
+With the **access** setting, you can match on:
+
+* a type of data access (read or write);
+* one of primary tables access (Discretes Input, Coils, Input Registers and Holding Registers);
+* a range of addresses access;
+* a written value.
+
+Syntax::
+
+ modbus: access <read | write>
+ modbus: access <read | write> <discretes | coils | input | holding>
+ modbus: access <read | write> <discretes | coils | input | holding>, address <value>
+ modbus: access <read | write> <discretes | coils | input | holding>, address <value>, value <value>
+
+With _<value>_ setting matches on the address or value as it is being
+accessed or written as follows::
+
+ address 100 # exactly address 100
+ address 100<>200 # greater than address 100 and smaller than address 200
+ address >100 # greater than address 100
+ address <100 # smaller than address 100
+
+Examples::
+
+ modbus: access read # Read access
+ modbus: access write # Write access
+ modbus: access read input # Read access to Discretes Input table
+ modbus: access write coils # Write access to Coils table
+ modbus: access read discretes, address <100 # Read access at address smaller than 100 of Discretes Input table
+ modbus: access write holding, address 500, value >200 # Write value greather than 200 at address 500 of Holding Registers table
+
+(cf. http://www.modbus.org/docs/Modbus_Application_Protocol_V1_1b3.pdf)
+
+**Note:** Address of read and write are starting at 1. So if your system
+is using a start at 0, you need to add 1 the address values.
+
+**Note:** According to MODBUS Messaging on TCP/IP Implementation Guide
+V1.0b, it is recommended to keep the TCP connection opened with a
+remote device and not to open and close it for each MODBUS/TCP
+transaction. In that case, it is important to set the depth of the
+stream reassembling as unlimited (stream.reassembly.depth: 0)
+
+(cf. http://www.modbus.org/docs/Modbus_Messaging_Implementation_Guide_V1_0b.pdf)
+
+Paper and presentation (in french) on Modbus support are available :
+http://www.ssi.gouv.fr/fr/anssi/publications/publications-scientifiques/articles-de-conferences/detection-d-intrusion-dans-les-systemes-industriels-suricata-et-le-cas-modbus.html