#ifdef HAVE_PRI_INBANDDISCONNECT
unsigned int inbanddisconnect:1; /*!< Should we support inband audio after receiving DISCONNECT? */
#endif
+ /*! TRUE if we have already whined about no D channels available. */
+ unsigned int no_d_channels:1;
time_t lastreset; /*!< time when unused channels were last reset */
long resetinterval; /*!< Interval (in seconds) for resetting unused channels */
/*! \brief ISDN signalling type (SIG_PRI, SIG_BRI, SIG_BRI_PTMP, etc...) */
if (newslot < 0) {
newslot = 0;
/* This is annoying to see on non persistent layer 2 connections. Let's not complain in that case */
- if (pri->sig != SIG_BRI_PTMP) {
- ast_log(LOG_WARNING, "No D-channels available! Using Primary channel %d as D-channel anyway!\n",
+ if (pri->sig != SIG_BRI_PTMP && !pri->no_d_channels) {
+ pri->no_d_channels = 1;
+ ast_log(LOG_WARNING,
+ "No D-channels available! Using Primary channel %d as D-channel anyway!\n",
pri->dchannels[newslot]);
}
+ } else {
+ pri->no_d_channels = 0;
}
if (old && (oldslot != newslot))
ast_log(LOG_NOTICE, "Switching from from d-channel %d to channel %d!\n",
switch (e->e) {
case PRI_EVENT_DCHAN_UP:
+ pri->no_d_channels = 0;
if (!pri->pri) pri_find_dchan(pri);
/* Note presense of D-channel */