The SMC1 block on i.MX7ULP is already used as a clock provider in
imx7ulp.dtsi, but the corresponding dt-binding schema does not define
the required '#clock-cells' property. This results in CHECK_DTBS schema
validation errors.
Functionally, SMC1 controls the CPU run mode configuration:
- 00b: Normal Run (RUN)
- 10b: Very-Low-Power Run (VLPR)
- 11b: High-Speed Run (HSRUN)
These run modes determine the effective CPU operating point, and their
programming is tied to the OPP table.
Add the missing `#clock-cells` definition so the dt-binding schema is
consistent with the DTS and validates correctly.
Fixes: 8ba41d6bd9893 ("dt-bindings: fsl: Convert i.MX7ULP PM to json-schema")
Reviewed-by: Krzysztof Kozlowski <krzysztof.kozlowski@oss.qualcomm.com>
Signed-off-by: Peng Fan <peng.fan@nxp.com>
Signed-off-by: Frank Li <Frank.Li@nxp.com>
reg:
maxItems: 1
+ '#clock-cells':
+ const: 1
+
clocks:
maxItems: 2
required:
- compatible
- reg
+ - '#clock-cells'
additionalProperties: false
smc1@40410000 {
compatible = "fsl,imx7ulp-smc1";
reg = <0x40410000 0x1000>;
+ #clock-cells = <1>;
};