it makes absolutely zero sense to have "uses = 2". This means
that the connections will get closed in the middle of the unit
tests.
pool {
start = 1
min = 0
- max = 1
+ max = 10
spare = 3
- uses = 2
- lifetime = 1
+ lifetime = 0
idle_timeout = 60
retry_delay = 1
}
pool {
start = 0
min = 0
- max = 1
+ max = 10
spare = 3
- uses = 2
- lifetime = 1
+ lifetime = 0
idle_timeout = 60
retry_delay = 1
}
pool {
start = 1
min = 0
- max = 1
+ max = 10
spare = 3
- uses = 2
- lifetime = 1
+ lifetime = 0
idle_timeout = 60
retry_delay = 1
}
read_groups = yes
pool {
- start = 0
+ start = 1
min = 0
- max = 1
+ max = 10
spare = 3
- uses = 2
- lifetime = 1
+ lifetime = 0
idle_timeout = 60
retry_delay = 1
}
read_groups = yes
pool {
- start = 0
+ start = 1
min = 0
- max = 1
+ max = 10
spare = 3
- lifetime = 1
+ lifetime = 0
idle_timeout = 60
retry_delay = 1
}
pool {
start = 1
min = 0
- max = 1
+ max = 10
spare = 3
- lifetime = 1
+ lifetime = 0
idle_timeout = 60
retry_delay = 1
}
pool {
start = 1
min = 0
- max = 1
- spare = 1
- lifetime = 1
+ max = 10
+ spare = 3
+ lifetime = 0
+ idle_timeout = 60
retry_delay = 1
}
pool {
start = 1
min = 0
- max = 1
- spare = 1
- lifetime = 1
+ max = 10
+ spare = 3
+ lifetime = 0
idle_timeout = 60
retry_delay = 1
}