Although value 4 (INDOOR_SP_AP_OLD) is deprecated in IEEE standards,
existing APs may still use this control value. Since this value is
based on the old specification, we cannot trust such APs implement
proper power controls.
Therefore, move IEEE80211_6GHZ_CTRL_REG_INDOOR_SP_AP_OLD case
from SP_AP to LPI_AP power type handling to prevent potential
power limit violations.
Signed-off-by: Pagadala Yesu Anjaneyulu <pagadala.yesu.anjaneyulu@intel.com>
Reviewed-by: Johannes Berg <johannes.berg@intel.com>
Signed-off-by: Miri Korenblit <miriam.rachel.korenblit@intel.com>
Link: https://patch.msgid.link/20260111163601.6b5a36d3601e.I1704ee575fd25edb0d56f48a0a3169b44ef72ad0@changeid
Signed-off-by: Johannes Berg <johannes.berg@intel.com>
case IEEE80211_6GHZ_CTRL_REG_LPI_AP:
case IEEE80211_6GHZ_CTRL_REG_INDOOR_LPI_AP:
case IEEE80211_6GHZ_CTRL_REG_AP_ROLE_NOT_RELEVANT:
+ case IEEE80211_6GHZ_CTRL_REG_INDOOR_SP_AP_OLD:
return IEEE80211_REG_LPI_AP;
case IEEE80211_6GHZ_CTRL_REG_SP_AP:
- case IEEE80211_6GHZ_CTRL_REG_INDOOR_SP_AP_OLD:
return IEEE80211_REG_SP_AP;
case IEEE80211_6GHZ_CTRL_REG_VLP_AP:
return IEEE80211_REG_VLP_AP;