From: Bjarni Ingi Gislason Date: Sun, 28 Jun 2020 22:46:26 +0000 (+0000) Subject: man8/bridge.8: fix misuse of two-fonts macros X-Git-Tag: v5.8.0~29 X-Git-Url: http://git.ipfire.org/cgi-bin/gitweb.cgi?a=commitdiff_plain;h=57cfcc62afbf7817db351ac412d66677496c4fc3;p=thirdparty%2Fiproute2.git man8/bridge.8: fix misuse of two-fonts macros Use a single-font macro for a single argument. Signed-off-by: Bjarni Ingi Gislason Signed-off-by: Stephen Hemminger --- diff --git a/man/man8/bridge.8 b/man/man8/bridge.8 index 71f2e890d..efe67f7b6 100644 --- a/man/man8/bridge.8 +++ b/man/man8/bridge.8 @@ -28,10 +28,9 @@ bridge \- show / manipulate bridge addresses and devices \fB\-o\fR[\fIneline\fr] } .ti -8 -.BR "bridge link set" +.B "bridge link set" .B dev -.IR DEV -.IR " [ " +.IR DEV " [ " .B cost .IR COST " ] [ " .B priority @@ -106,9 +105,9 @@ bridge \- show / manipulate bridge addresses and devices .ti -8 .BR "bridge mdb" " { " add " | " del " } " .B dev -.IR DEV +.I DEV .B port -.IR PORT +.I PORT .B grp .IR GROUP " [ " .BR permanent " | " temp " ] [ " @@ -123,10 +122,10 @@ bridge \- show / manipulate bridge addresses and devices .ti -8 .BR "bridge vlan" " { " add " | " del " } " .B dev -.IR DEV +.I DEV .B vid .IR VID " [ " -.BR tunnel_info +.B tunnel_info .IR TUNNEL_ID " ] [ " .BR pvid " ] [ " untagged " ] [ " .BR self " ] [ " master " ] " @@ -166,7 +165,7 @@ to the specified network namespace Actually it just simplifies executing of: .B ip netns exec -.IR NETNS +.I NETNS .B bridge .RI "[ " OPTIONS " ] " OBJECT " { " COMMAND " | " .BR help " }" @@ -183,7 +182,7 @@ Read commands from provided file or standard input and invoke them. First failure will cause termination of bridge command. .TP -.BR "\-force" +.B "\-force" Don't terminate bridge command on errors in batch mode. If there were any errors during execution of the commands, the application return code will be non zero. @@ -393,7 +392,7 @@ bridge FDB. Controls whether a given port will flood unicast traffic for which there is no FDB entry. By default this flag is on. .TP -.BI hwmode +.B hwmode Some network interface cards support HW bridge functionality and they may be configured in different modes. Currently support modes are: @@ -417,7 +416,7 @@ instead of multicast. By default this flag is off. This is done by copying the packet per host and changing the multicast destination MAC to a unicast one accordingly. -.BR mcast_to_unicast +.B mcast_to_unicast works on top of the multicast snooping feature of the bridge. Which means unicast copies are only delivered to hosts which are interested in it and signalized this via IGMP/MLD reports @@ -462,15 +461,15 @@ If the port loses carrier all traffic will be redirected to the configured backup port .TP -.BR nobackup_port +.B nobackup_port Removes the currently configured backup port .TP -.BI self +.B self link setting is configured on specified physical device .TP -.BI master +.B master link setting is configured on the software bridge (default) .TP @@ -499,7 +498,7 @@ and delete old ones. This command creates a new fdb entry. .TP -.BI "LLADDR" +.B LLADDR the Ethernet MAC address. .TP @@ -626,7 +625,7 @@ and last used time for each entry. lookup a bridge forwarding table entry. .TP -.BI "LLADDR" +.B LLADDR the Ethernet MAC address. .TP @@ -750,21 +749,21 @@ dst_metadata for every packet that belongs to this vlan (applicable to bridge ports with vlan_tunnel flag set). .TP -.BI pvid +.B pvid the vlan specified is to be considered a PVID at ingress. Any untagged frames will be assigned to this VLAN. .TP -.BI untagged +.B untagged the vlan specified is to be treated as untagged on egress. .TP -.BI self +.B self the vlan is configured on the specified physical device. Required if the device is the bridge device. .TP -.BI master +.B master the vlan is configured on the software bridge (default). .SS bridge vlan delete - delete a vlan filter entry