From: Zbigniew Jędrzejewski-Szmek Date: Fri, 27 Sep 2024 18:17:12 +0000 (+0200) Subject: systemctl: fix printing of RootImageOptions X-Git-Tag: v257-rc1~363^2~1 X-Git-Url: http://git.ipfire.org/cgi-bin/gitweb.cgi?a=commitdiff_plain;h=69c751c61cb2b386afe51f03b58f8f7ceeeb643e;p=thirdparty%2Fsystemd.git systemctl: fix printing of RootImageOptions The type is a(ss), so a custom printer is required. Fixes https://github.com/systemd/systemd/issues/33967. --- diff --git a/src/systemctl/systemctl-show.c b/src/systemctl/systemctl-show.c index 2f39bc2b12f..67a72bdc94a 100644 --- a/src/systemctl/systemctl-show.c +++ b/src/systemctl/systemctl-show.c @@ -1769,6 +1769,29 @@ static int print_property(const char *name, const char *expected_value, sd_bus_m return bus_log_parse_error(r); return 1; + + } else if (streq(name, "RootImageOptions")) { + const char *a, *p; + + /* In config files, the syntax allows the partition name to be omitted. Here, we + * always print the partition name, also because we have no way of knowing if it was + * originally omitted or not. We also print the partitions on separate lines. */ + + r = sd_bus_message_enter_container(m, SD_BUS_TYPE_ARRAY, "(ss)"); + if (r < 0) + return bus_log_parse_error(r); + + while ((r = sd_bus_message_read(m, "(ss)", &a, &p)) > 0) + bus_print_property_valuef(name, expected_value, flags, "%s:%s", a, p); + if (r < 0) + return bus_log_parse_error(r); + + r = sd_bus_message_exit_container(m); + if (r < 0) + return bus_log_parse_error(r); + + return 1; + } else if (streq(name, "MountImages")) { _cleanup_free_ char *paths = NULL;