From: Rafael J. Wysocki Date: Mon, 25 Aug 2025 13:28:34 +0000 (+0200) Subject: thermal: gov_step_wise: Clarify cooling logic description comment X-Git-Tag: v6.18-rc1~150^2~7 X-Git-Url: http://git.ipfire.org/cgi-bin/gitweb.cgi?a=commitdiff_plain;h=6b4decef4c9454a9121109788fae761319ea44b4;p=thirdparty%2Flinux.git thermal: gov_step_wise: Clarify cooling logic description comment The cooling logic description comment next to the get_target_state() definition is slightly ambiguous in what it means by "lower cooling state", so clarify that by replacing the ambuguous phrase with "the minimum applicable cooling state". No functional impact. Signed-off-by: Rafael J. Wysocki Reviewed-by: Lukasz Luba Link: https://patch.msgid.link/4690596.LvFx2qVVIh@rafael.j.wysocki --- diff --git a/drivers/thermal/gov_step_wise.c b/drivers/thermal/gov_step_wise.c index 6506ae270101a..a29676d3e50dc 100644 --- a/drivers/thermal/gov_step_wise.c +++ b/drivers/thermal/gov_step_wise.c @@ -23,8 +23,8 @@ * b. if the trend is THERMAL_TREND_DROPPING, do nothing * If the temperature is lower than a trip point, * a. if the trend is THERMAL_TREND_RAISING, do nothing - * b. if the trend is THERMAL_TREND_DROPPING, use lower cooling - * state for this trip point, if the cooling state already + * b. if the trend is THERMAL_TREND_DROPPING, use the minimum applicable + * cooling state for this trip point, or if the cooling state already * equals lower limit, deactivate the thermal instance */ static unsigned long get_target_state(struct thermal_instance *instance,