From 7657bf0b7cfb63ded95a6fe4e1cf106cf386b6cc Mon Sep 17 00:00:00 2001 From: Angela Czubak Date: Mon, 18 Aug 2025 23:08:48 +0000 Subject: [PATCH] HID: input: calculate resolution for pressure Assume that if the pressure is given in newtons it should be normalized to grams. If the pressure has no unit do not calculate resolution. Signed-off-by: Angela Czubak Co-developed-by: Jonathan Denose Signed-off-by: Jonathan Denose Signed-off-by: Benjamin Tissoires --- drivers/hid/hid-input.c | 13 +++++++++++++ 1 file changed, 13 insertions(+) diff --git a/drivers/hid/hid-input.c b/drivers/hid/hid-input.c index f6a920fe3102e..5d7532d79d21c 100644 --- a/drivers/hid/hid-input.c +++ b/drivers/hid/hid-input.c @@ -303,6 +303,19 @@ __s32 hidinput_calc_abs_res(const struct hid_field *field, __u16 code) } break; + case ABS_PRESSURE: + case ABS_MT_PRESSURE: + if (field->unit == HID_UNIT_NEWTON) { + /* Convert to grams, 1 newton is 101.97 grams */ + prev = physical_extents; + physical_extents *= 10197; + if (physical_extents < prev) + return 0; + unit_exponent -= 2; + } else if (field->unit != HID_UNIT_GRAM) { + return 0; + } + break; default: return 0; } -- 2.47.3