From 9c78317b42e7c32523c91099859bc4721e9f75dd Mon Sep 17 00:00:00 2001 From: Sean Nyekjaer Date: Mon, 5 May 2025 21:20:08 +0200 Subject: [PATCH] iio: accel: fxls8962af: Fix temperature scan element sign Mark the temperature element signed, data read from the TEMP_OUT register is in two's complement format. This will avoid the temperature being mishandled and miss displayed. Fixes: a3e0b51884ee ("iio: accel: add support for FXLS8962AF/FXLS8964AF accelerometers") Suggested-by: Marcelo Schmitt Cc: stable@vger.kernel.org Reviewed-by: Marcelo Schmitt Signed-off-by: Sean Nyekjaer Link: https://patch.msgid.link/20250505-fxls-v4-2-a38652e21738@geanix.com Signed-off-by: Jonathan Cameron --- drivers/iio/accel/fxls8962af-core.c | 1 + 1 file changed, 1 insertion(+) diff --git a/drivers/iio/accel/fxls8962af-core.c b/drivers/iio/accel/fxls8962af-core.c index 5f5e917f7aa53..ae965a8f560d3 100644 --- a/drivers/iio/accel/fxls8962af-core.c +++ b/drivers/iio/accel/fxls8962af-core.c @@ -749,6 +749,7 @@ static const struct iio_event_spec fxls8962af_event[] = { BIT(IIO_CHAN_INFO_OFFSET),\ .scan_index = -1, \ .scan_type = { \ + .sign = 's', \ .realbits = 8, \ .storagebits = 8, \ }, \ -- 2.47.2