From b5fd1849c684e60e9d0a5adcc937507676f6920f Mon Sep 17 00:00:00 2001 From: David Lechner Date: Thu, 19 Dec 2024 13:25:23 -0600 Subject: [PATCH] iio: ABI: combine current input sections Combine two duplicate sections describing in_currentY_raw. This went unnoticed until we renamed in_currentX_raw to in_currentY_raw and the kernel test robot found the duplication. Reported-by: kernel test robot Closes: https://lore.kernel.org/oe-kbuild-all/202412200256.OB5Hmw5Q-lkp@intel.com/ Signed-off-by: David Lechner Link: https://patch.msgid.link/20241219-iio-abi-combine-current-input-sections-v1-1-8dcd8221d469@baylibre.com Signed-off-by: Jonathan Cameron --- Documentation/ABI/testing/sysfs-bus-iio | 19 +++++-------------- 1 file changed, 5 insertions(+), 14 deletions(-) diff --git a/Documentation/ABI/testing/sysfs-bus-iio b/Documentation/ABI/testing/sysfs-bus-iio index d97c35057a034..25d366d452a55 100644 --- a/Documentation/ABI/testing/sysfs-bus-iio +++ b/Documentation/ABI/testing/sysfs-bus-iio @@ -168,18 +168,6 @@ Description: is required is a consistent labeling. Units after application of scale and offset are millivolts. -What: /sys/bus/iio/devices/iio:deviceX/in_currentY_raw -What: /sys/bus/iio/devices/iio:deviceX/in_currentY_supply_raw -KernelVersion: 3.17 -Contact: linux-iio@vger.kernel.org -Description: - Raw (unscaled no bias removal etc.) current measurement from - channel Y. In special cases where the channel does not - correspond to externally available input one of the named - versions may be used. The number must always be specified and - unique to allow association with event codes. Units after - application of scale and offset are milliamps. - What: /sys/bus/iio/devices/iio:deviceX/in_powerY_raw KernelVersion: 4.5 Contact: linux-iio@vger.kernel.org @@ -1700,15 +1688,18 @@ Description: or without compensation from tilt sensors. What: /sys/bus/iio/devices/iio:deviceX/in_currentY_raw +What: /sys/bus/iio/devices/iio:deviceX/in_currentY_supply_raw What: /sys/bus/iio/devices/iio:deviceX/in_currentY_i_raw What: /sys/bus/iio/devices/iio:deviceX/in_currentY_q_raw -KernelVersion: 3.18 +KernelVersion: 3.17 Contact: linux-iio@vger.kernel.org Description: Raw current measurement from channel Y. Units are in milliamps after application of scale and offset. If no offset or scale is present, output should be considered as processed with the - unit in milliamps. + unit in milliamps. In special cases where the channel does not + correspond to externally available input one of the named + versions may be used. Channels with 'i' and 'q' modifiers always exist in pairs and both channels refer to the same signal. The 'i' channel contains the in-phase -- 2.47.3