Since commit
0bcd01f757bc ("hwmon: Introduce 64-bit energy attribute
support"), devices can report 64-bit energy values by selecting the
sensor type "energy64". However, such sensors can't report their labels
since is_string_attr() was not updated to match it.
Add label support for 64-bit energy attributes by updating
is_string_attr() to match hwmon_energy64 in addition to hwmon_energy.
Signed-off-by: Rong Zhang <i@rong.moe>
Link: https://lore.kernel.org/r/20260327-b4-hwmon-witrn-v1-1-8d2f1896c045@rong.moe
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
(type == hwmon_curr && attr == hwmon_curr_label) ||
(type == hwmon_power && attr == hwmon_power_label) ||
(type == hwmon_energy && attr == hwmon_energy_label) ||
+ (type == hwmon_energy64 && attr == hwmon_energy_label) ||
(type == hwmon_humidity && attr == hwmon_humidity_label) ||
(type == hwmon_fan && attr == hwmon_fan_label);
}