When driver signals carrier up via netif_carrier_on() its internal
link_up state isn't updated immediately. This leads to inconsistent
speed/duplex in /proc/net/bonding/bondX where the speed and duplex
is shown as unknown while ethtool shows correct values. Fix this by
using netif_carrier_ok() for link checking in get_ksettings function.
Fixes: 84421b99cedc ("tg3: Update link_up flag for phylib devices")
Signed-off-by: Thomas Bogendoerfer <tbogendoerfer@suse.de>
Reviewed-by: Pavan Chebbi <pavan.chebbi@broadcom.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
ethtool_convert_legacy_u32_to_link_mode(cmd->link_modes.advertising,
advertising);
- if (netif_running(dev) && tp->link_up) {
+ if (netif_running(dev) && netif_carrier_ok(dev)) {
cmd->base.speed = tp->link_config.active_speed;
cmd->base.duplex = tp->link_config.active_duplex;
ethtool_convert_legacy_u32_to_link_mode(