" [ group_fwd_mask MASK ]\n"
" [ group_address ADDRESS ]\n"
" [ no_linklocal_learn NO_LINKLOCAL_LEARN ]\n"
+ " [ fdb_local_vlan_0 FDB_LOCAL_VLAN_0 ]\n"
" [ fdb_max_learned FDB_MAX_LEARNED ]\n"
" [ vlan_filtering VLAN_FILTERING ]\n"
" [ vlan_protocol VLAN_PROTOCOL ]\n"
bm.optval |= mofn_bit;
else
bm.optval &= ~mofn_bit;
+ } else if (strcmp(*argv, "fdb_local_vlan_0") == 0) {
+ __u32 bit = 1 << BR_BOOLOPT_FDB_LOCAL_VLAN_0;
+ __u8 value;
+
+ NEXT_ARG();
+ if (get_u8(&value, *argv, 0))
+ invarg("invalid fdb_local_vlan_0", *argv);
+ bm.optmask |= bit;
+ if (value)
+ bm.optval |= bit;
+ else
+ bm.optval &= ~bit;
} else if (matches(*argv, "help") == 0) {
explain();
return -1;
if (tb[IFLA_BR_MULTI_BOOLOPT]) {
__u32 mofn_bit = 1 << BR_BOOLOPT_MDB_OFFLOAD_FAIL_NOTIFICATION;
+ __u32 fdb_vlan_0_bit = 1 << BR_BOOLOPT_FDB_LOCAL_VLAN_0;
__u32 mcvl_bit = 1 << BR_BOOLOPT_MCAST_VLAN_SNOOPING;
__u32 no_ll_learn_bit = 1 << BR_BOOLOPT_NO_LL_LEARN;
__u32 mst_bit = 1 << BR_BOOLOPT_MST_ENABLE;
"mdb_offload_fail_notification",
"mdb_offload_fail_notification %u ",
!!(bm->optval & mofn_bit));
+ if (bm->optmask & fdb_vlan_0_bit)
+ print_uint(PRINT_ANY,
+ "fdb_local_vlan_0",
+ "fdb_local_vlan_0 %u ",
+ !!(bm->optval & fdb_vlan_0_bit));
}
if (tb[IFLA_BR_MCAST_ROUTER])
] [
.BI no_linklocal_learn " NO_LINKLOCAL_LEARN "
] [
+.BI fdb_local_vlan_0 " FDB_LOCAL_VLAN_0 "
+] [
.BI fdb_max_learned " FDB_MAX_LEARNED "
] [
.BI vlan_filtering " VLAN_FILTERING "
When disabled, the bridge will not learn from link-local frames (default:
enabled).
+.BI fdb_local_vlan_0 " FDB_LOCAL_VLAN_0 "
+When disabled, local FDB entries (i.e. those for member port addresses and
+address of the bridge itself) are kept at VLAN 0 as well as any member VLANs.
+When the option is enabled, they are only kept at VLAN 0. By default the
+option is disabled.
+
+When this option is enabled, when making a forwarding decision, the bridge looks
+at VLAN 0 for a matching entry that is permanent, but not added by user. However
+in all other ways the entry only exists on VLAN 0. This affects dumping, where
+the entries are not shown on non-0 VLANs, and FDB get and flush do not find the
+entry on non-0 VLANs. When the entry is deleted, it affects forwarding on all
+VLANs.
+
.BI fdb_max_learned " FDB_MAX_LEARNED "
- set the maximum number of learned FDB entries. If
.RI ( FDB_MAX_LEARNED " == 0) "