platform/x86: hp-wmi: add locking for concurrent hwmon access
hp_wmi_hwmon_priv.mode and .pwm are written by hp_wmi_hwmon_write() in
sysfs context and read by hp_wmi_hwmon_keep_alive_handler() in a
workqueue. A concurrent write and keep-alive expiry can observe an
inconsistent mode/pwm pair (e.g. mode=MANUAL with a stale pwm).
Add a mutex to hp_wmi_hwmon_priv protecting mode and pwm. Hold it in
hp_wmi_hwmon_write() across the field update and apply call, and in
hp_wmi_hwmon_keep_alive_handler() before calling apply.
In hp_wmi_hwmon_read(), only the pwm_enable path reads priv->mode; use
scoped_guard() there to avoid holding the lock across unrelated WMI
calls.
Fixes: c203c59fb5de ("platform/x86: hp-wmi: implement fan keep-alive")
Suggested-by: Ilpo Järvinen <ilpo.jarvinen@linux.intel.com>
Signed-off-by: Emre Cecanpunar <emreleno@gmail.com>
Link: https://patch.msgid.link/20260407142515.20683-6-emreleno@gmail.com
Reviewed-by: Ilpo Järvinen <ilpo.jarvinen@linux.intel.com>
Signed-off-by: Ilpo Järvinen <ilpo.jarvinen@linux.intel.com>