<Data "ifmib_if_octets32">
Type "if_octets"
Table true
- Instance "IF-MIB::ifDescr"
+ TypeInstanceOID "IF-MIB::ifDescr"
Values "IF-MIB::ifInOctets" "IF-MIB::ifOutOctets"
</Data>
<Data "ifmib_if_octets64">
Type "if_octets"
Table true
- Instance "IF-MIB::ifName"
+ TypeInstanceOID "IF-MIB::ifName"
Values "IF-MIB::ifHCInOctets" "IF-MIB::ifHCOutOctets"
</Data>
<Data "ifmib_if_packets32">
Type "if_packets"
Table true
- Instance "IF-MIB::ifDescr"
+ TypeInstanceOID "IF-MIB::ifDescr"
Values "IF-MIB::ifInUcastPkts" "IF-MIB::ifOutUcastPkts"
</Data>
<Data "ifmib_if_packets64">
Type "if_packets"
Table true
- Instance "IF-MIB::ifName"
+ TypeInstanceOID "IF-MIB::ifName"
Values "IF-MIB::ifHCInUcastPkts" "IF-MIB::ifHCOutUcastPkts"
</Data>
<Data "ifmib_if_errors32">
Type "if_errors"
Table true
- Instance "IF-MIB::ifDescr"
+ TypeInstanceOID "IF-MIB::ifDescr"
Values "IF-MIB::ifInErrors" "IF-MIB::ifOutErrors"
</Data>
<Data "ifmib_if_errors64">
Type "if_errors"
Table true
- Instance "IF-MIB::ifName"
+ TypeInstanceOID "IF-MIB::ifName"
Values "IF-MIB::ifHCInErrors" "IF-MIB::ifHCOutErrors"
</Data>
<Data "upsmib_timeleft_battery">
Type "timeleft"
Table false
- Instance "battery"
+ TypeInstanceOID "battery"
Values ".1.3.6.1.2.1.33.1.2.3.0"
</Data>
<Data "upsmib_charge_battery">
Type "percent"
Table false
- Instance "charge-battery"
+ TypeInstanceOID "charge-battery"
Values ".1.3.6.1.2.1.33.1.2.4.0"
</Data>
<Data "upsmib_voltage_battery">
Type "voltage"
Table false
- Instance "battery"
+ TypeInstanceOID "battery"
Values ".1.3.6.1.2.1.33.1.2.5.0"
Scale 0.1
</Data>
<Data "upsmib_current_battery">
Type "current"
Table false
- Instance "battery"
+ TypeInstanceOID "battery"
Values ".1.3.6.1.2.1.33.1.2.6.0"
Scale 0.1
</Data>
<Data "upsmib_temperature_battery">
Type "temperature"
Table false
- Instance "battery"
+ TypeInstanceOID "battery"
Values ".1.3.6.1.2.1.33.1.2.7.0"
</Data>
# Input branch
<Data "upsmib_frequency_input">
Type "frequency"
Table true
- InstancePrefix "input"
+ TypeInstancePrefix "input"
Values ".1.3.6.1.2.1.33.1.3.3.1.2"
Scale 0.1
</Data>
<Data "upsmib_voltage_input">
Type "voltage"
Table true
- InstancePrefix "input"
+ TypeInstancePrefix "input"
Values ".1.3.6.1.2.1.33.1.3.3.1.3"
</Data>
<Data "upsmib_current_input">
Type "current"
Table true
- InstancePrefix "input"
+ TypeInstancePrefix "input"
Values ".1.3.6.1.2.1.33.1.3.3.1.4"
Scale 0.1
</Data>
<Data "upsmib_power_input">
Type "power"
Table true
- InstancePrefix "input"
+ TypeInstancePrefix "input"
Values ".1.3.6.1.2.1.33.1.3.3.1.5"
</Data>
# Output branch
<Data "upsmib_frequency_output">
Type "frequency"
Table false
- Instance "output"
+ TypeInstanceOID "output"
Values ".1.3.6.1.2.1.33.1.4.2.0"
Scale 0.1
</Data>
<Data "upsmib_voltage_output">
Type "voltage"
Table true
- InstancePrefix "output"
+ TypeInstancePrefix "output"
Values ".1.3.6.1.2.1.33.1.4.4.1.2"
</Data>
<Data "upsmib_current_output">
Type "current"
Table true
- InstancePrefix "output"
+ TypeInstancePrefix "output"
Values ".1.3.6.1.2.1.33.1.4.4.1.3"
Scale 0.1
</Data>
<Data "upsmib_power_output">
Type "power"
Table true
- InstancePrefix "output"
+ TypeInstancePrefix "output"
Values ".1.3.6.1.2.1.33.1.4.4.1.4"
</Data>
<Data "upsmib_load_output">
Type "percent"
Table true
- InstancePrefix "load-output"
+ TypeInstancePrefix "load-output"
Values ".1.3.6.1.2.1.33.1.4.4.1.5"
</Data>
# Bypass branch
<Data "upsmib_frequency_bypass">
Type "frequency"
Table false
- Instance "output"
+ TypeInstanceOID "output"
Values ".1.3.6.1.2.1.33.1.5.1.0"
Scale 0.1
</Data>
<Data "upsmib_voltage_bypass">
Type "voltage"
Table true
- InstancePrefix "bypass"
+ TypeInstancePrefix "bypass"
Values ".1.3.6.1.2.1.33.1.5.3.1.2"
</Data>
<Data "upsmib_current_bypass">
Type "current"
Table true
- InstancePrefix "bypass"
+ TypeInstancePrefix "bypass"
Values ".1.3.6.1.2.1.33.1.5.3.1.3"
Scale 0.1
</Data>
<Data "upsmib_power_bypass">
Type "power"
Table true
- InstancePrefix "bypass"
+ TypeInstancePrefix "bypass"
Values ".1.3.6.1.2.1.33.1.5.3.1.4"
</Data>
# Special definitions for broken UPSes
<Data "upsmib_voltage_battery_unscaled">
Type "voltage"
Table false
- Instance "battery"
+ TypeInstanceOID "battery"
Values ".1.3.6.1.2.1.33.1.2.5.0"
</Data>
<Data "upsmib_current_input_unscaled">
Type "current"
Table true
- InstancePrefix "input"
+ TypeInstancePrefix "input"
Values ".1.3.6.1.2.1.33.1.3.3.1.4"
</Data>
<Data "upsmib_current_output_unscaled">
Type "current"
Table true
- InstancePrefix "output"
+ TypeInstancePrefix "output"
Values ".1.3.6.1.2.1.33.1.4.4.1.3"
</Data>
<Data "riello_temperature_system">
Type "temperature"
Table false
- Instance "system"
+ TypeInstanceOID "system"
Values ".1.3.6.1.4.1.5491.1.51.1.5.4.0"
</Data>
<Data "riello_temperature_rectifier">
Type "temperature"
Table false
- Instance "rectifier"
+ TypeInstanceOID "rectifier"
Values ".1.3.6.1.4.1.5491.1.51.1.5.5.0"
</Data>
<Data "riello_temperature_inverter">
Type "temperature"
Table false
- Instance "inverter"
+ TypeInstanceOID "inverter"
Values ".1.3.6.1.4.1.5491.1.51.1.5.6.0"
</Data>
<Data "powerplus_voltage_input">
Type "voltage"
Table true
- InstancePrefix "input"
+ TypeInstancePrefix "input"
Values ".1.3.6.1.4.1.6050.5.4.1.1.2"
</Data>
<Data "powerplus_current_input">
Type "current"
Table true
- InstancePrefix "input"
+ TypeInstancePrefix "input"
Values ".1.3.6.1.4.1.6050.5.4.1.1.3"
</Data>
<Data "powerplus_power_apparent_input">
Type "power"
Table true
- InstancePrefix "apparent-input"
+ TypeInstancePrefix "apparent-input"
Values ".1.3.6.1.4.1.6050.5.4.1.1.4"
Scale 100.0
</Data>
<Data "powerplus_power_active_input">
Type "power"
Table true
- InstancePrefix "active-input"
+ TypeInstancePrefix "active-input"
Values ".1.3.6.1.4.1.6050.5.4.1.1.5"
Scale 100.0
</Data>
<Data "powerplus_performance_factor_input">
Type "percent"
Table true
- InstancePrefix "performance_factor-input"
+ TypeInstancePrefix "performance_factor-input"
Values ".1.3.6.1.4.1.6050.5.4.1.1.6"
</Data>
# Global outputs
<Data "powerplus_voltage_output">
Type "voltage"
Table true
- InstancePrefix "output"
+ TypeInstancePrefix "output"
Values ".1.3.6.1.4.1.6050.5.5.1.1.2"
</Data>
<Data "powerplus_current_output">
Type "current"
Table true
- InstancePrefix "output"
+ TypeInstancePrefix "output"
Values ".1.3.6.1.4.1.6050.5.5.1.1.3"
</Data>
<Data "powerplus_power_apparent_output">
Type "power"
Table true
- InstancePrefix "apparent-output"
+ TypeInstancePrefix "apparent-output"
Values ".1.3.6.1.4.1.6050.5.5.1.1.4"
Scale 100.0
</Data>
<Data "powerplus_power_active_output">
Type "power"
Table true
- InstancePrefix "active-output"
+ TypeInstancePrefix "active-output"
Values ".1.3.6.1.4.1.6050.5.5.1.1.5"
Scale 100.0
</Data>
<Data "powerplus_load_level_output">
Type "percent"
Table true
- InstancePrefix "load_level-output"
+ TypeInstancePrefix "load_level-output"
Values ".1.3.6.1.4.1.6050.5.5.1.1.6"
</Data>
<Data "powerplus_active_load_level_output">
Type "percent"
Table true
- InstancePrefix "active_load_level-output"
+ TypeInstancePrefix "active_load_level-output"
Values ".1.3.6.1.4.1.6050.5.5.1.1.7"
</Data>
<Data "powerplus_performance_factor_output">
Type "percent"
Table true
- InstancePrefix "performance_factor-output"
+ TypeInstancePrefix "performance_factor-output"
Values ".1.3.6.1.4.1.6050.5.5.1.1.8"
</Data>
# Global DC
<Data "powerplus_global_dc_positive">
Type "voltage"
Table false
- Instance "dc_positive-global"
+ TypeInstanceOID "dc_positive-global"
Values ".1.3.6.1.4.1.6050.5.6.1.0"
</Data>
<Data "powerplus_global_dc_negative">
Type "voltage"
Table false
- Instance "dc_negative-global"
+ TypeInstanceOID "dc_negative-global"
Values ".1.3.6.1.4.1.6050.5.6.2.0"
</Data>
<Data "powerplus_global_dc_total">
Type "voltage"
Table false
- Instance "dc_total-global"
+ TypeInstanceOID "dc_total-global"
Values ".1.3.6.1.4.1.6050.5.6.3.0"
</Data>
<Data "netapp_cpu_system">
Type "cpu"
Table false
- Instance "system"
+ TypeInstanceOID "system"
Values ".1.3.6.1.4.1.789.1.2.1.2.0"
</Data>
<Data "netapp_cpu_idle">
Type "cpu"
Table false
- Instance "idle"
+ TypeInstanceOID "idle"
Values ".1.3.6.1.4.1.789.1.2.1.4.0"
</Data>
<Data "netapp_if_octets">
Type "if_octets"
Table false
- Instance "net"
+ TypeInstanceOID "net"
Values ".1.3.6.1.4.1.789.1.2.2.12.0" ".1.3.6.1.4.1.789.1.2.2.14.0"
</Data>
<Data "juniperssl_users_web">
Type "users"
Table false
- Instance "web"
+ TypeInstanceOID "web"
Values ".1.3.6.1.4.1.12532.2.0"
</Data>
<Data "juniperssl_users_mail">
Type "users"
Table false
- Instance "mail"
+ TypeInstanceOID "mail"
Values ".1.3.6.1.4.1.12532.3.0"
</Data>
<Data "juniperssl_percent_logfull">
Type "percent"
Table false
- Instance "logfull"
+ TypeInstanceOID "logfull"
Values ".1.3.6.1.4.1.12532.1.0"
</Data>
<Data "juniperssl_percent_diskfull">
Type "percent"
Table false
- Instance "diskfull"
+ TypeInstanceOID "diskfull"
Values ".1.3.6.1.4.1.12532.25.0"
</Data>
<Data "wut_an8graph">
Type "temperature"
Table true
- Instance ".1.3.6.1.4.1.5040.1.2.6.3.2.1.1.2"
+ TypeInstanceOID ".1.3.6.1.4.1.5040.1.2.6.3.2.1.1.2"
Values ".1.3.6.1.4.1.5040.1.2.6.1.4.1.1"
Scale 0.1
</Data>
<Data "wut_an2graph">
Type "temperature"
Table true
- Instance ".1.3.6.1.4.1.5040.1.2.7.3.2.1.1.2"
+ TypeInstanceOID ".1.3.6.1.4.1.5040.1.2.7.3.2.1.1.2"
Values ".1.3.6.1.4.1.5040.1.2.7.1.4.1.1"
Scale 0.1
</Data>
<Data "wut_an1graph">
Type "temperature"
Table true
- Instance ".1.3.6.1.4.1.5040.1.2.8.3.2.1.1.2"
+ TypeInstanceOID ".1.3.6.1.4.1.5040.1.2.8.3.2.1.1.2"
Values ".1.3.6.1.4.1.5040.1.2.8.1.4.1.1"
Scale 0.1
</Data>
<Data "wut_thermo8">
Type "temperature"
Table true
- Instance ".1.3.6.1.4.1.5040.1.2.1.3.2.1.1.2"
+ TypeInstanceOID ".1.3.6.1.4.1.5040.1.2.1.3.2.1.1.2"
Values ".1.3.6.1.4.1.5040.1.2.1.1.4.1.1"
Scale 0.1
</Data>
<Data "wut_thermo2">
Type "temperature"
Table true
- Instance ".1.3.6.1.4.1.5040.1.2.2.3.2.1.1.2"
+ TypeInstanceOID ".1.3.6.1.4.1.5040.1.2.2.3.2.1.1.2"
Values ".1.3.6.1.4.1.5040.1.2.2.1.4.1.1"
Scale 0.1
</Data>
<Data "wut_thermo1">
Type "temperature"
Table true
- Instance ".1.3.6.1.4.1.5040.1.2.3.3.2.1.1.2"
+ TypeInstanceOID ".1.3.6.1.4.1.5040.1.2.3.3.2.1.1.2"
Values ".1.3.6.1.4.1.5040.1.2.3.1.4.1.1"
Scale 0.1
</Data>
<Data "infratec_h2_17_temperature">
Type "temperature"
Table true
- Instance ".1.3.6.1.4.1.4519.10.4.1.1.2"
+ TypeInstanceOID ".1.3.6.1.4.1.4519.10.4.1.1.2"
Values ".1.3.6.1.4.1.4519.10.4.1.1.3"
</Data>
<Data "infratec_h2_17_humidity">
Type "humidity"
Table true
- Instance ".1.3.6.1.4.1.4519.10.5.1.1.2"
+ TypeInstanceOID ".1.3.6.1.4.1.4519.10.5.1.1.2"
Values ".1.3.6.1.4.1.4519.10.5.1.1.3"
</Data>
<Data "infratec_h2_17_voltage">
Type "voltage"
Table true
- InstancePrefix "input"
+ TypeInstancePrefix "input"
Values ".1.3.6.1.4.1.4519.10.6.1.1.3"
</Data>
# Model H2-30
<Data "infratec_h2_30_temperature">
Type "temperature"
Table true
- Instance ".1.3.6.1.4.1.1909.10.4.1.1.2"
+ TypeInstanceOID ".1.3.6.1.4.1.1909.10.4.1.1.2"
Values ".1.3.6.1.4.1.1909.10.4.1.1.3"
</Data>
<Data "infratec_h2_30_humidity">
Type "humidity"
Table true
- Instance ".1.3.6.1.4.1.1909.10.5.1.1.2"
+ TypeInstanceOID ".1.3.6.1.4.1.1909.10.5.1.1.2"
Values ".1.3.6.1.4.1.1909.10.5.1.1.3"
</Data>
<Data "infratec_h2_30_voltage">
Type "voltage"
Table true
- InstancePrefix "input"
+ TypeInstancePrefix "input"
Values ".1.3.6.1.4.1.1909.10.6.1.1.3"
</Data>
<Data "mikrotik_wl_sta_bitrate_tx">
tYPE "Bitrate"
Table true
- InstancePrefix "st-tx-"
- Instance ".1.3.6.1.4.1.14988.1.1.1.1.1.5"
+ TypeInstancePrefix "st-tx-"
+ TypeInstanceOID ".1.3.6.1.4.1.14988.1.1.1.1.1.5"
Values ".1.3.6.1.4.1.14988.1.1.1.1.1.2"
</Data>
<Data "mikrotik_wl_sta_bitrate_rx">
Type "bitrate"
Table true
- InstancePrefix "st-rx-"
- Instance ".1.3.6.1.4.1.14988.1.1.1.1.1.5"
+ TypeInstancePrefix "st-rx-"
+ TypeInstanceOID ".1.3.6.1.4.1.14988.1.1.1.1.1.5"
Values ".1.3.6.1.4.1.14988.1.1.1.1.1.3"
</Data>
<Data "mikrotik_wl_sta_signal">
Type "signal_power"
Table true
- InstancePrefix "st-"
- Instance ".1.3.6.1.4.1.14988.1.1.1.1.1.5"
+ TypeInstancePrefix "st-"
+ TypeInstanceOID ".1.3.6.1.4.1.14988.1.1.1.1.1.5"
Values ".1.3.6.1.4.1.14988.1.1.1.1.1.4"
</Data>
<Data "mikrotik_wl_reg_signal">
Type "signal_power"
Table true
- InstancePrefix "ap-"
- Instance ".1.3.6.1.4.1.14988.1.1.1.2.1.1"
+ TypeInstancePrefix "ap-"
+ TypeInstanceOID ".1.3.6.1.4.1.14988.1.1.1.2.1.1"
Values ".1.3.6.1.4.1.14988.1.1.1.2.1.3"
</Data>
<Data "mikrotik_wl_reg_octets">
Type "if_octets"
Table true
- InstancePrefix "ap-"
- Instance ".1.3.6.1.4.1.14988.1.1.1.2.1.1"
+ TypeInstancePrefix "ap-"
+ TypeInstanceOID ".1.3.6.1.4.1.14988.1.1.1.2.1.1"
Values ".1.3.6.1.4.1.14988.1.1.1.2.1.5" ".1.3.6.1.4.1.14988.1.1.1.2.1.4"
</Data>
<Data "mikrotik_wl_reg_packets">
Type "if_packets"
Table true
- InstancePrefix "ap-"
- Instance ".1.3.6.1.4.1.14988.1.1.1.2.1.1"
+ TypeInstancePrefix "ap-"
+ TypeInstanceOID ".1.3.6.1.4.1.14988.1.1.1.2.1.1"
Values ".1.3.6.1.4.1.14988.1.1.1.2.1.7" ".1.3.6.1.4.1.14988.1.1.1.2.1.6"
</Data>
<Data "mikrotik_wl_reg_bitrate_tx">
Type "bitrate"
Table true
- InstancePrefix "ap-tx-"
- Instance ".1.3.6.1.4.1.14988.1.1.1.2.1.1"
+ TypeInstancePrefix "ap-tx-"
+ TypeInstanceOID ".1.3.6.1.4.1.14988.1.1.1.2.1.1"
Values ".1.3.6.1.4.1.14988.1.1.1.2.1.8"
</Data>
<Data "mikrotik_wl_reg_bitrate_rx">
Type "bitrate"
Table true
- InstancePrefix "ap-rx-"
- Instance ".1.3.6.1.4.1.14988.1.1.1.2.1.1"
+ TypeInstancePrefix "ap-rx-"
+ TypeInstanceOID ".1.3.6.1.4.1.14988.1.1.1.2.1.1"
Values ".1.3.6.1.4.1.14988.1.1.1.2.1.9"
</Data>
</Plugin>