Commit | Line | Data |
---|---|---|
1 | #! /bin/sh | |
2 | ### BEGIN INIT INFO | |
3 | # Provides: nut | |
4 | # Required-Start: $local_fs $syslog $network | |
5 | # Required-Stop: $local_fs $syslog $network | |
6 | # Default-Start: 2 3 4 5 | |
7 | # Default-Stop: 0 1 6 | |
8 | # Short-Description: Network UPS Tools initscript | |
9 | # Description: This script take care of starting and stopping the | |
10 | # Network UPS Tools components. When needed, it also | |
11 | # handle the UPS hardware shutdown. | |
12 | ### END INIT INFO | |
13 | ||
14 | # Author: Arnaud Quette <aquette@debian.org> | |
15 | ||
16 | PATH=/sbin:/usr/sbin:/bin:/usr/bin:/usr/local/sbin:/usr/local/bin | |
17 | ||
18 | NAME=nut | |
19 | DESC="Network UPS Tools" | |
20 | DEFAULT=/etc/sysconfig/nut | |
21 | CONFIG=/etc/nut/nut.conf | |
22 | ||
23 | . /etc/sysconfig/rc | |
24 | . $rc_functions | |
25 | ||
26 | # set upsd specific options. use "man upsd" for more info | |
27 | UPSD_OPTIONS="" | |
28 | ||
29 | # set upsmon specific options. use "man upsmon" for more info | |
30 | UPSMON_OPTIONS="" | |
31 | ||
32 | # Include defaults if available (transition period) | |
33 | if [ -f $DEFAULT ] ; then | |
34 | . $DEFAULT | |
35 | fi | |
36 | ||
37 | # Include NUT nut.conf | |
38 | if [ -f $CONFIG ] ; then | |
39 | . $CONFIG | |
40 | fi | |
41 | ||
42 | # Explicitly require the configuration to be done in /etc/nut/nut.conf | |
43 | if [ "x$MODE" = "xnone" ] ; then | |
44 | log_failure_msg "$NAME disabled, please adjust the configuration to your needs " | |
45 | log_failure_msg "and then set MODE to a suitable value in $CONFIG to enable it." | |
46 | # exit success to avoid breaking the install process! | |
47 | exit 0 | |
48 | fi | |
49 | ||
50 | pid_dir=/var/run/nut | |
51 | upsmon_pid=${pid_dir}/upsmon.pid | |
52 | upsd_pid=${pid_dir}/upsd.pid | |
53 | upsd=/usr/sbin/upsd | |
54 | upsdrvctl=/usr/bin/upsdrvctl | |
55 | upsmon=/usr/sbin/upsmon | |
56 | log=">/dev/null 2>/dev/null" | |
57 | ||
58 | # Check if /var/run/nut exists and has the correct perms | |
59 | check_var_directory() { | |
60 | [ ! -d ${pid_dir} ] && mkdir -p ${pid_dir} \ | |
61 | && chown root:nut ${pid_dir} \ | |
62 | && chmod 770 ${pid_dir} | |
63 | } | |
64 | ||
65 | start_stop_server () { | |
66 | case "$MODE" in | |
67 | standalone|netserver) | |
68 | case "$1" in | |
69 | start) | |
70 | ! $upsdrvctl start >/dev/null 2>&1 && boot_mesg "(upsdrvctl failed)" | |
71 | $upsd $UPSD_OPTIONS >/dev/null 2>&1 | |
72 | ;; | |
73 | stop) | |
74 | $upsd -c stop >/dev/null 2>&1 | |
75 | ! $upsdrvctl stop >/dev/null 2>&1 && boot_mesg "(upsdrvctl failed)" | |
76 | ;; | |
77 | esac | |
78 | ;; | |
79 | none|netclient|*) | |
80 | return 1 | |
81 | ;; | |
82 | esac | |
83 | } | |
84 | ||
85 | start_stop_client () { | |
86 | case "$MODE" in | |
87 | standalone|netserver|netclient) | |
88 | case "$1" in | |
89 | start) | |
90 | $upsmon $UPSMON_OPTIONS >/dev/null 2>&1 | |
91 | ;; | |
92 | stop) | |
93 | $upsmon -c stop >/dev/null 2>&1 | |
94 | ;; | |
95 | esac | |
96 | ;; | |
97 | none|*) | |
98 | return 1 | |
99 | ;; | |
100 | esac | |
101 | } | |
102 | ||
103 | case "$1" in | |
104 | ||
105 | start) | |
106 | boot_mesg "Starting $DESC" | |
107 | check_var_directory | |
108 | start_stop_server start | |
109 | start_stop_client start | |
110 | ;; | |
111 | ||
112 | stop) | |
113 | boot_mesg "Stopping $DESC" | |
114 | start_stop_server stop | |
115 | start_stop_client stop | |
116 | ;; | |
117 | ||
118 | reload) | |
119 | $upsd -c reload >/dev/null 2>&1 | |
120 | $upsmon -c reload >/dev/null 2>&1 | |
121 | ;; | |
122 | ||
123 | restart|force-reload) | |
124 | boot_mesg "Restarting $DESC" | |
125 | start_stop_client stop | |
126 | start_stop_server stop | |
127 | sleep 5 | |
128 | check_var_directory | |
129 | start_stop_server start | |
130 | start_stop_client start | |
131 | ;; | |
132 | ||
133 | poweroff) | |
134 | flag=`sed -ne 's#^ *POWERDOWNFLAG *\(.*\)$#\1#p' /etc/nut/upsmon.conf` | |
135 | wait_delay=`sed -ne 's#^ *POWEROFF_WAIT= *\(.*\)$#\1#p' $CONFIG` | |
136 | if [ -f "$flag" ] ; then | |
137 | if $upsmon -K >/dev/null 2>&1 ; then | |
138 | boot_mesg "Shutting down the UPS ..." | |
139 | sleep 1 | |
140 | if $upsdrvctl shutdown ; then | |
141 | sleep 5 | |
142 | boot_mesg "Waiting for UPS to cut the power" | |
143 | else | |
144 | boot_mesg "Shutdown failed." | |
145 | boot_mesg "Waiting for UPS batteries to run down" | |
146 | fi | |
147 | if [ "$wait_delay" ] ; then | |
148 | boot_mesg " (will reboot after $wait_delay) ..." | |
149 | sleep "$wait_delay" | |
150 | /etc/init.d/reboot stop | |
151 | fi | |
152 | else | |
153 | boot_mesg "Power down flag is not set (UPS shutdown not needed)" | |
154 | fi | |
155 | else | |
156 | if [ -z "$flag" ] ; then | |
157 | boot_mesg "##########################################################" | |
158 | boot_mesg "## POWERDOWNFLAG is not defined in /etc/nut/upsmon.conf ##" | |
159 | boot_mesg "## ##" | |
160 | boot_mesg "## Please read the Manual page upsmon.conf(5) ##" | |
161 | boot_mesg "##########################################################" | |
162 | fi | |
163 | fi | |
164 | ;; | |
165 | ||
166 | *) | |
167 | N=/etc/init.d/$NAME | |
168 | echo "Usage: $N {start|stop|reload|restart|force-reload|poweroff}" >&2 | |
169 | exit 1 | |
170 | ;; | |
171 | esac | |
172 | ||