]> git.ipfire.org Git - thirdparty/man-pages.git/blobdiff - man4/hpsa.4
fd.4: ffix: tables: Move units from numbers to the header
[thirdparty/man-pages.git] / man4 / hpsa.4
index db807100c1f62433693db65d9eb4864618a7eb3c..63000bf7a45db8c29910b1ea7661c4379d27027d 100644 (file)
@@ -1,6 +1,9 @@
 .\" Copyright (C) 2011, Hewlett-Packard Development Company, L.P.
 .\" Written by Stephen M. Cameron <scameron@beardog.cce.hp.com>
+.\"
+.\" %%%LICENSE_START(GPLv2_ONELINE)
 .\" Licensed under GNU General Public License version 2 (GPLv2)
+.\" %%%LICENSE_END
 .\"
 .\" shorthand for double quote that works everywhere.
 .ds q \N'34'
@@ -33,12 +36,12 @@ not supported with
 and
 .BR cciss (4)
 should still be used for these.
-.SS Supported Hardware
+.SS Supported hardware
 The
 .B hpsa
 driver supports the following Smart Array boards:
+.PP
 .nf
-
     Smart Array P700M
     Smart Array P212
     Smart Array P410
@@ -48,9 +51,8 @@ driver supports the following Smart Array boards:
     Smart Array P712m
     Smart Array P711m
     StorageWorks P1210m
-
 .fi
-.SS Configuration Details
+.SS Configuration details
 To configure HP Smart Array controllers,
 use the HP Array Configuration Utility (either
 .BR hpacuxe (8)
@@ -59,7 +61,7 @@ or
 or the Offline ROM-based Configuration Utility (ORCA)
 run from the Smart Array's option ROM at boot time.
 .SH FILES
-.SS Device Nodes
+.SS Device nodes
 Logical drives are accessed via the SCSI disk driver
 .RB ( sd (4)),
 tape drives via the SCSI tape driver
@@ -68,17 +70,17 @@ and
 the RAID controller via the SCSI generic driver
 .RB ( sg (4)),
 with device nodes named
-.IR /dev/sd*,
+.IR /dev/sd* ,
 .IR /dev/st* ,
 and
 .IR /dev/sg* ,
 respectively.
-.SS HPSA-Specific Host Attribute Files in /sys
+.SS HPSA-specific host attribute files in /sys
 .TP
 .I /sys/class/scsi_host/host*/rescan
 This is a write-only attribute.
 Writing to this attribute will cause the driver to scan for
-new, changed, or removed devices (e.g,. hot-plugged tape drives,
+new, changed, or removed devices (e.g., hot-plugged tape drives,
 or newly configured or deleted logical drives, etc.)
 and notify the SCSI midlayer of any changes detected.
 Normally a rescan is triggered automatically
@@ -87,56 +89,65 @@ command-line variety);
 thus, for logical drive changes, the user should not
 normally have to use this attribute.
 This attribute may be useful when hot plugging devices like tape drives,
-or entire storage boxes containing pre-configured logical drives.
+or entire storage boxes containing preconfigured logical drives.
 .TP
 .I /sys/class/scsi_host/host*/firmware_revision
 This attribute contains the firmware version of the Smart Array.
-
+.IP
 For example:
-
-.nf
-    # \fBcd /sys/class/scsi_host/host4\fP
-    # \fBcat firmware_revision\fP
-    7.14
-.fi
-
-.SS HPSA-Specific Disk Attribute Files in /sys
+.IP
+.in +4n
+.EX
+# \fBcd /sys/class/scsi_host/host4\fP
+# \fBcat firmware_revision\fP
+7.14
+.EE
+.in
+.\"
+.SS HPSA-specific disk attribute files in /sys
 .TP
 .I /sys/class/scsi_disk/c:b:t:l/device/unique_id
 This attribute contains a 32 hex-digit unique ID for each logical drive.
-.nf
-
+.IP
 For example:
-
-    # \fBcd /sys/class/scsi_disk/4:0:0:0/device\fP
-    # \fBcat unique_id\fP
-    600508B1001044395355323037570F77
-.fi
+.IP
+.in +4n
+.EX
+# \fBcd /sys/class/scsi_disk/4:0:0:0/device\fP
+# \fBcat unique_id\fP
+600508B1001044395355323037570F77
+.EE
+.in
 .TP
 .I /sys/class/scsi_disk/c:b:t:l/device/raid_level
 This attribute contains the RAID level of each logical drive.
-.nf
-
+.IP
 For example:
-
-    # \fBcd /sys/class/scsi_disk/4:0:0:0/device\fP
-    # \fBcat raid_level\fP
-    RAID 0
-.fi
+.IP
+.in +4n
+.EX
+# \fBcd /sys/class/scsi_disk/4:0:0:0/device\fP
+# \fBcat raid_level\fP
+RAID 0
+.EE
+.in
 .TP
 .I /sys/class/scsi_disk/c:b:t:l/device/lunid
 This attribute contains the 16 hex-digit (8 byte) LUN ID
 by which a logical drive or physical device can be addressed.
 .IR c : b : t : l
-are the controller, bus, target and lun of the device.
-.nf
-
+are the controller, bus, target, and lun of the device.
+.PP
 For example:
-
-    # \fBcd /sys/class/scsi_disk/4:0:0:0/device\fP
-    # \fBcat lunid\fP
-    0x0000004000000000
-.fi
+.IP
+.in +4n
+.EX
+# \fBcd /sys/class/scsi_disk/4:0:0:0/device\fP
+# \fBcat lunid\fP
+0x0000004000000000
+.EE
+.in
+.\"
 .SS Supported ioctl() operations
 For compatibility with applications written for the
 .BR cciss (4)
@@ -161,28 +172,32 @@ Returns PCI domain, bus, device and function and "board ID" (PCI subsystem ID).
 .TP
 .B CCISS_GETDRIVVER
 Returns driver version in three bytes encoded as:
-.sp
-    (major_version << 16) | (minor_version << 8) |
-        (subminor_version)
+.IP
+.in +4n
+.EX
+(major_version << 16) | (minor_version << 8) |
+    (subminor_version)
+.EE
+.in
 .TP
 .BR CCISS_PASSTHRU ", " CCISS_BIG_PASSTHRU
 Allows "BMIC" and "CISS" commands to be passed through to the Smart Array.
 These are used extensively by the HP Array Configuration Utility,
-SNMP storage agents, etc.
+SNMP storage agents, and so on.
 See
 .I cciss_vol_status
 at
 .UR http://cciss.sf.net
 .UE
 for some examples.
-.SH "SEE ALSO"
+.SH SEE ALSO
 .BR cciss (4),
 .BR sd (4),
 .BR st (4),
 .BR cciss_vol_status (8),
 .BR hpacucli (8),
 .BR hpacuxe (8),
-
+.PP
 .UR http://cciss.sf.net
 .UE ,
 and